{"product_id":"abb-ge-tey3100st12-100-amp-3-pole-thermal-magnetic-circuit-breaker-bolt-on-120-240-480y-277v-ac","title":"ABB \/ GE TEY3100ST12 100 Amp 3 Pole Thermal Magnetic Circuit Breaker – Bolt-On – 120\/240\/480Y\/277V AC","description":"\u003cp data-start=\"128\" data-end=\"822\"\u003eThe ABB \/ GE TEY3100ST12 100 Amp three-pole molded case circuit breaker is designed for high-performance commercial and industrial power distribution systems. Part of the GE Q-Line TEY series, it provides reliable thermal-magnetic LI (Long-Time and Instantaneous) protection for branch circuits. This compact MCCB features a factory-installed 120–277VAC shunt trip mechanism, enabling remote tripping capability for enhanced system control and safety. Its bolt-on mounting design ensures a secure installation in GE A-Series panelboards. With high interrupt ratings up to 65kA at 120\/240V and 14kA at 480Y\/277V, it delivers strong fault current protection for demanding electrical environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"829\" data-end=\"851\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"852\" data-end=\"1127\"\u003e\n\u003cli data-section-id=\"zbvo8y\" data-start=\"852\" data-end=\"880\"\u003eCurrent Rating: 100 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1uh69vq\" data-start=\"881\" data-end=\"948\"\u003eVoltage Rating: 120VAC, 240VAC, 480Y\/277VAC, 250VDC, 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"949\" data-end=\"972\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"bv8d6i\" data-start=\"973\" data-end=\"1108\"\u003eInterrupting Capacity:\n\u003cul data-start=\"1002\" data-end=\"1108\"\u003e\n\u003cli data-section-id=\"1iznlnq\" data-start=\"1002\" data-end=\"1019\"\u003e65kA @ 120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1p8wawz\" data-start=\"1022\" data-end=\"1039\"\u003e65kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1r10rgr\" data-start=\"1042\" data-end=\"1064\"\u003e14kA @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gb0c1x\" data-start=\"1067\" data-end=\"1084\"\u003e10kA @ 250VDC\u003c\/li\u003e\n\u003cli data-section-id=\"tn5run\" data-start=\"1087\" data-end=\"1108\"\u003e65kA @ 120\/240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"1109\" data-end=\"1127\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1134\" data-end=\"1156\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1157\" data-end=\"1758\"\u003e\n\u003cli data-section-id=\"c6w748\" data-start=\"1157\" data-end=\"1209\"\u003eBreaker Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"137pbbb\" data-start=\"1210\" data-end=\"1259\"\u003eTrip Function: LI (Long-Time \u0026amp; Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1260\" data-end=\"1297\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"mwlhud\" data-start=\"1298\" data-end=\"1325\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1r8s1ht\" data-start=\"1326\" data-end=\"1351\"\u003eSeries: GE Q-Line TEY\u003c\/li\u003e\n\u003cli data-section-id=\"psyc29\" data-start=\"1352\" data-end=\"1379\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"tj7ycd\" data-start=\"1380\" data-end=\"1441\"\u003eApplication: Commercial and industrial power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"wf08ht\" data-start=\"1442\" data-end=\"1493\"\u003eCompatible Panelboards: GE A-Series Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"13fv1c6\" data-start=\"1494\" data-end=\"1538\"\u003eShunt Trip: Factory-installed 120–277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"uwd4vd\" data-start=\"1539\" data-end=\"1636\"\u003eAccessories Available: Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment\u003c\/li\u003e\n\u003cli data-section-id=\"yfuyny\" data-start=\"1637\" data-end=\"1758\"\u003eConstruction Features: HACR Rated, Common Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism, Non-Interchangeable Trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1765\" data-end=\"1793\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1794\" data-end=\"2118\"\u003e\n\u003cli data-section-id=\"1tr34fg\" data-start=\"1794\" data-end=\"1832\"\u003eWire Size Range: 4–1\/0 AWG (Cu\/Al)\u003c\/li\u003e\n\u003cli data-section-id=\"1wsvor4\" data-start=\"1833\" data-end=\"1854\"\u003eMax Wire: 1\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"opde44\" data-start=\"1855\" data-end=\"1874\"\u003eMin Wire: 4 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1yxht88\" data-start=\"1875\" data-end=\"1921\"\u003eTerminal Type: Line and Load Lugs Included\u003c\/li\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1922\" data-end=\"1959\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1crqvqj\" data-start=\"1960\" data-end=\"2013\"\u003eTrip Adjustability: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1v7q0dq\" data-start=\"2014\" data-end=\"2042\"\u003eTemperature Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"15hcvqh\" data-start=\"2043\" data-end=\"2118\"\u003eCertifications\/Approvals: UL 489, CSA C22.2 No. 5, CSA, HACR, UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2125\" data-end=\"2141\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"2142\" data-end=\"2246\"\u003e\n\u003cli data-section-id=\"6t9q2m\" data-start=\"2142\" data-end=\"2182\"\u003eManufacturer: ABB \/ General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"hkshwo\" data-start=\"2183\" data-end=\"2211\"\u003ePart Number: TEY3100ST12\u003c\/li\u003e\n\u003cli data-section-id=\"8xl4n5\" data-start=\"2212\" data-end=\"2227\"\u003eSeries: TEY\u003c\/li\u003e\n\u003cli data-section-id=\"1a05cra\" data-start=\"2228\" data-end=\"2246\"\u003eFamily: Q-Line\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48435261243641,"sku":"TEY3100ST12","price":893.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/TEY3100ST12-3-Pole-Circuit-Breaker_General-Electric_1.webp?v=1779551962","url":"https:\/\/mycircuitbreakers.com\/products\/abb-ge-tey3100st12-100-amp-3-pole-thermal-magnetic-circuit-breaker-bolt-on-120-240-480y-277v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}