{"product_id":"abb-ge-thhqb1130gft-30-amp-1-pole-gfci-circuit-breaker-q-line-bolt-on-120-240v-ac","title":"ABB \/ GE THHQB1130GFT 30 Amp 1 Pole GFCI Circuit Breaker – Q-Line – Bolt-On – 120\/240V AC","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-6a11c9d2-fa5c-83e8-934f-b46429aa1619-11\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a11c9d2-fa5c-83e8-934f-b46429aa1619-11\" data-turn-id-container=\"request-6a11c9d2-fa5c-83e8-934f-b46429aa1619-11\" data-testid=\"conversation-turn-176\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"c5eda554-3dae-4a81-8ad7-5fe00e926d73\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"116\" data-end=\"669\"\u003eThe ABB \/ GE THHQB1130GFT is a 30 Amp, 1-pole Q-Line molded case circuit breaker with integrated Class A ground-fault (GFCI) protection. Designed for commercial and light industrial electrical systems, it provides overload, short-circuit, and ground-fault protection in a single device. This breaker is built for installation in GE A-Series panelboards and AQ lighting panels using a bolt-on mounting design. It is a direct replacement for the older THHQB1130GF model and complies with NEC requirements for personnel protection in damp or wet locations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"676\" data-end=\"698\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"699\" data-end=\"906\"\u003e\n\u003cli data-section-id=\"l4zkeo\" data-start=\"699\" data-end=\"726\"\u003eCurrent Rating: 30 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"rsdr0p\" data-start=\"727\" data-end=\"758\"\u003eVoltage Rating: 120\/240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"adzwuk\" data-start=\"759\" data-end=\"781\"\u003eNumber of Poles: 1\u003c\/li\u003e\n\u003cli data-section-id=\"cs2c47\" data-start=\"782\" data-end=\"811\"\u003eSystem Type: Single-phase\u003c\/li\u003e\n\u003cli data-section-id=\"1xmufpi\" data-start=\"812\" data-end=\"856\"\u003eInterrupting Rating: 22 kA @ 120\/240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1r3omm5\" data-start=\"857\" data-end=\"906\"\u003eDevice Type: GFCI Molded Case Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"913\" data-end=\"935\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"936\" data-end=\"1253\"\u003e\n\u003cli data-section-id=\"d5v1tf\" data-start=\"936\" data-end=\"962\"\u003eSeries: Q-Line \/ THHQB\u003c\/li\u003e\n\u003cli data-section-id=\"ike13k\" data-start=\"963\" data-end=\"1029\"\u003eTrip Technology: Thermal Magnetic with Ground Fault Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1g552sm\" data-start=\"1030\" data-end=\"1100\"\u003eProtection Functions: Long-Time, Instantaneous, Ground Fault (LIG)\u003c\/li\u003e\n\u003cli data-section-id=\"1ecug2v\" data-start=\"1101\" data-end=\"1145\"\u003eGround Fault Sensitivity: Class A (5 mA)\u003c\/li\u003e\n\u003cli data-section-id=\"psyc29\" data-start=\"1146\" data-end=\"1173\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1qo8qyj\" data-start=\"1174\" data-end=\"1233\"\u003eApplication: Commercial panelboards and lighting panels\u003c\/li\u003e\n\u003cli data-section-id=\"jpillx\" data-start=\"1234\" data-end=\"1253\"\u003eBrand: ABB \/ GE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1260\" data-end=\"1288\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1289\" data-end=\"1627\"\u003e\n\u003cli data-section-id=\"ebtjh2\" data-start=\"1289\" data-end=\"1316\"\u003eTerminal Type: Box lugs\u003c\/li\u003e\n\u003cli data-section-id=\"6ap2mr\" data-start=\"1317\" data-end=\"1380\"\u003eWire Range:\n\u003cul data-start=\"1335\" data-end=\"1380\"\u003e\n\u003cli data-section-id=\"1qwesfq\" data-start=\"1335\" data-end=\"1355\"\u003eCopper: 14–8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"poom1t\" data-start=\"1358\" data-end=\"1380\"\u003eAluminum: 12–8 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e7xi7f\" data-start=\"1381\" data-end=\"1446\"\u003eTrip Features: Fixed thermal, instantaneous, and ground fault\u003c\/li\u003e\n\u003cli data-section-id=\"evc4p3\" data-start=\"1447\" data-end=\"1524\"\u003eSafety Features: Self-test function, non-interchangeable trip, HACR rated\u003c\/li\u003e\n\u003cli data-section-id=\"2d83xq\" data-start=\"1525\" data-end=\"1574\"\u003eOperation: Quick-make \/ Quick-break mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"7pskyx\" data-start=\"1575\" data-end=\"1627\"\u003eAccessories: Padlock attachment option available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1634\" data-end=\"1661\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1662\" data-end=\"1793\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"1662\" data-end=\"1672\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"7u0m2m\" data-start=\"1673\" data-end=\"1699\"\u003eUL 943 (GFCI standard)\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"1700\" data-end=\"1717\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"1718\" data-end=\"1732\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"tmrr2s\" data-start=\"1733\" data-end=\"1793\"\u003eNEC compliant for personnel protection in damp locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1800\" data-end=\"1816\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1817\" data-end=\"2003\"\u003e\n\u003cli data-section-id=\"6t9q2m\" data-start=\"1817\" data-end=\"1857\"\u003eManufacturer: ABB \/ General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"7amaab\" data-start=\"1858\" data-end=\"1890\"\u003eCatalog Number: THHQB1130GFT\u003c\/li\u003e\n\u003cli data-section-id=\"1qm2ujy\" data-start=\"1891\" data-end=\"1941\"\u003eProduct Type: GFCI Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"d5v1tf\" data-start=\"1942\" data-end=\"1968\"\u003eSeries: Q-Line \/ THHQB\u003c\/li\u003e\n\u003cli data-section-id=\"unyr7q\" data-start=\"1969\" data-end=\"2003\"\u003eReplacement Model: THHQB1130GF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2010\" data-end=\"2026\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2027\" data-end=\"2266\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"120admn\" data-start=\"2027\" data-end=\"2074\"\u003eCommercial lighting and receptacle circuits\u003c\/li\u003e\n\u003cli data-section-id=\"15jlrrj\" data-start=\"2075\" data-end=\"2124\"\u003eDamp and wet location protection requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1kwx4lj\" data-start=\"2125\" data-end=\"2166\"\u003eIndustrial and commercial panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"gf6zjh\" data-start=\"2167\" data-end=\"2212\"\u003ePersonnel ground-fault protection systems\u003c\/li\u003e\n\u003cli data-section-id=\"1yrxlhe\" data-start=\"2213\" data-end=\"2266\" data-is-last-node=\"\"\u003eBranch circuit protection in A-Series and AQ panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48440333598969,"sku":"THHQB1130GFT","price":176.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000028010_400x400_7c1e13b3-780e-4bf5-9be1-fe9e751c5042.jpg?v=1779654470","url":"https:\/\/mycircuitbreakers.com\/products\/abb-ge-thhqb1130gft-30-amp-1-pole-gfci-circuit-breaker-q-line-bolt-on-120-240v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}