{"product_id":"abb-ge-thql1115afp2-15-amp-1-pole-combination-arc-fault-circuit-breaker-thql-q-line-120-240v-ac","title":"ABB \/ GE THQL1115AFP2 15 Amp 1 Pole Combination Arc Fault Circuit Breaker – THQL Q-Line – 120\/240V AC","description":"\u003cp data-start=\"128\" data-end=\"634\"\u003eThe ABB \/ GE THQL1115AFP2 is a 15 Amp, 1-pole Combination Arc Fault Circuit Interrupter (CAFCI) breaker designed to provide advanced protection against both parallel and series arc faults in residential and commercial electrical systems. Part of the Q-Line THQL series, this plug-in thermal-magnetic breaker helps reduce the risk of electrical fires while also providing standard overload and short-circuit protection. It installs easily into compatible GE load centers using a plug-in mounting connection.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"641\" data-end=\"663\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"664\" data-end=\"884\"\u003e\n\u003cli data-section-id=\"i8nj07\" data-start=\"664\" data-end=\"691\"\u003eCurrent Rating: 15 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"rsdr0p\" data-start=\"692\" data-end=\"723\"\u003eVoltage Rating: 120\/240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"adzwuk\" data-start=\"724\" data-end=\"746\"\u003eNumber of Poles: 1\u003c\/li\u003e\n\u003cli data-section-id=\"gyivdz\" data-start=\"747\" data-end=\"778\"\u003ePhase: 1-phase applications\u003c\/li\u003e\n\u003cli data-section-id=\"7wlec1\" data-start=\"779\" data-end=\"821\"\u003eInterrupting Rating: 10 kAIC @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"wj3slh\" data-start=\"822\" data-end=\"884\"\u003eDevice Type: Combination Arc Fault Circuit Breaker (CAFCI)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"891\" data-end=\"913\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"914\" data-end=\"1133\"\u003e\n\u003cli data-section-id=\"1b336g\" data-start=\"914\" data-end=\"943\"\u003eSeries: THQ \/ THQL Q-Line\u003c\/li\u003e\n\u003cli data-section-id=\"sbdk2e\" data-start=\"944\" data-end=\"964\"\u003eFrame Type: THQL\u003c\/li\u003e\n\u003cli data-section-id=\"1urdxgj\" data-start=\"965\" data-end=\"1016\"\u003eBreaker Type: Thermal Magnetic Combination AFCI\u003c\/li\u003e\n\u003cli data-section-id=\"1kkh616\" data-start=\"1017\" data-end=\"1044\"\u003eMounting Style: Plug-On\u003c\/li\u003e\n\u003cli data-section-id=\"8qa68o\" data-start=\"1045\" data-end=\"1073\"\u003eConnection Type: Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"13xt03\" data-start=\"1074\" data-end=\"1099\"\u003eActuator Type: Toggle\u003c\/li\u003e\n\u003cli data-section-id=\"451q6q\" data-start=\"1100\" data-end=\"1133\"\u003eBrand: ABB \/ General Electric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1140\" data-end=\"1168\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1169\" data-end=\"1509\"\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1169\" data-end=\"1206\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1207\" data-end=\"1233\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"bv66pi\" data-start=\"1234\" data-end=\"1311\"\u003eTrip Functions:\n\u003cul data-start=\"1256\" data-end=\"1311\"\u003e\n\u003cli data-section-id=\"a6h1ax\" data-start=\"1256\" data-end=\"1280\"\u003eLong-Time Protection\u003c\/li\u003e\n\u003cli data-section-id=\"mfo9bn\" data-start=\"1283\" data-end=\"1311\"\u003eInstantaneous Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dgptqf\" data-start=\"1312\" data-end=\"1365\"\u003eSpecial Feature: Combination Arc Fault Protection\u003c\/li\u003e\n\u003cli data-section-id=\"19a41op\" data-start=\"1366\" data-end=\"1394\"\u003eContactor Type: Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"zy8qkw\" data-start=\"1395\" data-end=\"1509\"\u003eConstruction Features:\n\u003cul data-start=\"1424\" data-end=\"1509\"\u003e\n\u003cli data-section-id=\"umo33x\" data-start=\"1424\" data-end=\"1447\"\u003eArc fault detection\u003c\/li\u003e\n\u003cli data-section-id=\"uhpt8x\" data-start=\"1450\" data-end=\"1473\"\u003eQuick trip response\u003c\/li\u003e\n\u003cli data-section-id=\"1co02l7\" data-start=\"1476\" data-end=\"1509\"\u003eCompact plug-in configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1516\" data-end=\"1543\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1544\" data-end=\"1595\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"1544\" data-end=\"1557\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1tja0jr\" data-start=\"1558\" data-end=\"1576\"\u003eNEMA Standards\u003c\/li\u003e\n\u003cli data-section-id=\"1frae9h\" data-start=\"1577\" data-end=\"1595\"\u003eANSI Standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1602\" data-end=\"1618\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1619\" data-end=\"1812\"\u003e\n\u003cli data-section-id=\"6t9q2m\" data-start=\"1619\" data-end=\"1659\"\u003eManufacturer: ABB \/ General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1w2rwci\" data-start=\"1660\" data-end=\"1692\"\u003eCatalog Number: THQL1115AFP2\u003c\/li\u003e\n\u003cli data-section-id=\"13n2wae\" data-start=\"1693\" data-end=\"1714\"\u003eUPC: 783164652826\u003c\/li\u003e\n\u003cli data-section-id=\"4zot0k\" data-start=\"1715\" data-end=\"1737\"\u003eGTIN: 783164652826\u003c\/li\u003e\n\u003cli data-section-id=\"1pa8my\" data-start=\"1738\" data-end=\"1761\"\u003eSeries: THQL Q-Line\u003c\/li\u003e\n\u003cli data-section-id=\"16fte1a\" data-start=\"1762\" data-end=\"1812\"\u003eProduct Type: Combination AFCI Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bpec4l\" data-start=\"1819\" data-end=\"1833\"\u003eDimensions\u003c\/h3\u003e\n\u003cul data-start=\"1834\" data-end=\"1891\"\u003e\n\u003cli data-section-id=\"1r90p0w\" data-start=\"1834\" data-end=\"1853\"\u003eLength: 6.45 in\u003c\/li\u003e\n\u003cli data-section-id=\"7i8699\" data-start=\"1854\" data-end=\"1872\"\u003eWidth: 4.15 in\u003c\/li\u003e\n\u003cli data-section-id=\"13fyocm\" data-start=\"1873\" data-end=\"1891\"\u003eHeight: 1.3 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1898\" data-end=\"1914\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1915\" data-end=\"2143\" data-is-only-node=\"\" data-is-last-node=\"\"\u003e\n\u003cli data-section-id=\"g1wlzy\" data-start=\"1915\" data-end=\"1956\"\u003eResidential branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"mgfg7v\" data-start=\"1957\" data-end=\"1993\"\u003eBedroom and living area circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1nb3ot4\" data-start=\"1994\" data-end=\"2031\"\u003eArc fault protection applications\u003c\/li\u003e\n\u003cli data-section-id=\"1xno06e\" data-start=\"2032\" data-end=\"2058\"\u003eGE Q-Line load centers\u003c\/li\u003e\n\u003cli data-section-id=\"120admn\" data-start=\"2059\" data-end=\"2106\"\u003eCommercial lighting and receptacle circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1q4iooe\" data-start=\"2107\" data-end=\"2143\" data-is-last-node=\"\"\u003eElectrical fire prevention systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48445084958969,"sku":"THQL1115AFP2","price":78.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000028010_400x400_089cf4d3-bc76-4f5c-9d78-c34f05a29991.jpg?v=1779718505","url":"https:\/\/mycircuitbreakers.com\/products\/abb-ge-thql1115afp2-15-amp-1-pole-combination-arc-fault-circuit-breaker-thql-q-line-120-240v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}