{"product_id":"abb-ge-thql1130gfep-30-amp-1-pole-ground-fault-equipment-protection-circuit-breaker-thql-q-line-120-240v-ac","title":"ABB \/ GE THQL1130GFEP 30 Amp 1 Pole Ground Fault Equipment Protection Circuit Breaker – THQL Q-Line – 120\/240V AC","description":"\u003cp data-start=\"140\" data-end=\"647\"\u003eThe ABB \/ GE THQL1130GFEP is a 30 Amp, 1-pole Ground Fault Equipment Protection (GFEP) circuit breaker designed to protect electrical equipment from damaging ground fault currents. Part of the THQL Q-Line series, this breaker combines thermal-magnetic overcurrent protection with equipment-level ground fault protection, helping reduce the risk of equipment damage in residential and commercial electrical systems. It installs into compatible GE load centers and panelboards using a plug-in mounting design.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"654\" data-end=\"676\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"677\" data-end=\"880\"\u003e\n\u003cli data-section-id=\"l4zkeo\" data-start=\"677\" data-end=\"704\"\u003eCurrent Rating: 30 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"rsdr0p\" data-start=\"705\" data-end=\"736\"\u003eVoltage Rating: 120\/240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"adzwuk\" data-start=\"737\" data-end=\"759\"\u003eNumber of Poles: 1\u003c\/li\u003e\n\u003cli data-section-id=\"1cz2rjh\" data-start=\"760\" data-end=\"806\"\u003eInterrupting Rating: 10 kAIC @ 120\/240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"p81tqy\" data-start=\"807\" data-end=\"880\"\u003eDevice Type: Ground Fault Equipment Protection (GFEP) Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"887\" data-end=\"909\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"910\" data-end=\"1106\"\u003e\n\u003cli data-section-id=\"1pa8my\" data-start=\"910\" data-end=\"933\"\u003eSeries: THQL Q-Line\u003c\/li\u003e\n\u003cli data-section-id=\"w9rgde\" data-start=\"934\" data-end=\"989\"\u003eBreaker Type: Thermal Magnetic with GFEP protection\u003c\/li\u003e\n\u003cli data-section-id=\"1kkh616\" data-start=\"990\" data-end=\"1017\"\u003eMounting Style: Plug-On\u003c\/li\u003e\n\u003cli data-section-id=\"1n2wikv\" data-start=\"1018\" data-end=\"1072\"\u003eProtection Type: Equipment Ground Fault Protection\u003c\/li\u003e\n\u003cli data-section-id=\"451q6q\" data-start=\"1073\" data-end=\"1106\"\u003eBrand: ABB \/ General Electric\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1113\" data-end=\"1141\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1142\" data-end=\"1507\"\u003e\n\u003cli data-section-id=\"1mssztx\" data-start=\"1142\" data-end=\"1264\"\u003eProtection Functions:\n\u003cul data-start=\"1170\" data-end=\"1264\"\u003e\n\u003cli data-section-id=\"14s7m03\" data-start=\"1170\" data-end=\"1193\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"xnufhj\" data-start=\"1196\" data-end=\"1224\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"ftnbce\" data-start=\"1227\" data-end=\"1264\"\u003eGround fault equipment protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1265\" data-end=\"1302\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1c17alg\" data-start=\"1303\" data-end=\"1332\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"188pogg\" data-start=\"1333\" data-end=\"1507\"\u003eConstruction Features:\n\u003cul data-start=\"1362\" data-end=\"1507\"\u003e\n\u003cli data-section-id=\"1mdxkn5\" data-start=\"1362\" data-end=\"1398\"\u003eQuick-make\/quick-break mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"wmlbuj\" data-start=\"1401\" data-end=\"1444\"\u003eCompact Q-Line one-inch per pole design\u003c\/li\u003e\n\u003cli data-section-id=\"5v6n1z\" data-start=\"1447\" data-end=\"1473\"\u003eVisual trip indication\u003c\/li\u003e\n\u003cli data-section-id=\"32il3p\" data-start=\"1476\" data-end=\"1507\"\u003eReliable fault interruption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1514\" data-end=\"1541\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1542\" data-end=\"1573\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"1542\" data-end=\"1555\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"1556\" data-end=\"1573\"\u003eCSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1580\" data-end=\"1596\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1597\" data-end=\"1755\"\u003e\n\u003cli data-section-id=\"6t9q2m\" data-start=\"1597\" data-end=\"1637\"\u003eManufacturer: ABB \/ General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1cimk2c\" data-start=\"1638\" data-end=\"1670\"\u003eCatalog Number: THQL1130GFEP\u003c\/li\u003e\n\u003cli data-section-id=\"r26fh4\" data-start=\"1671\" data-end=\"1692\"\u003eUPC: 783164321074\u003c\/li\u003e\n\u003cli data-section-id=\"1pa8my\" data-start=\"1693\" data-end=\"1716\"\u003eSeries: THQL Q-Line\u003c\/li\u003e\n\u003cli data-section-id=\"mez1am\" data-start=\"1717\" data-end=\"1755\"\u003eProduct Type: GFEP Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1762\" data-end=\"1778\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1779\" data-end=\"1993\"\u003e\n\u003cli data-section-id=\"xnl78u\" data-start=\"1779\" data-end=\"1816\"\u003eEquipment ground fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"3pgt4y\" data-start=\"1817\" data-end=\"1833\"\u003eHVAC systems\u003c\/li\u003e\n\u003cli data-section-id=\"limnaf\" data-start=\"1834\" data-end=\"1875\"\u003eCommercial and industrial panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"iabfnp\" data-start=\"1876\" data-end=\"1910\"\u003eMotor and machinery protection\u003c\/li\u003e\n\u003cli data-section-id=\"bh0aay\" data-start=\"1911\" data-end=\"1946\"\u003eElectrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kalvrq\" data-start=\"1947\" data-end=\"1993\"\u003eGE Q-Line load centers and lighting panels\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48445110911225,"sku":"THQL1130GFEP","price":151.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/THQB1115GFEP_center_image_400Wx400H_6155a4a9-a35f-4525-8db8-8fa84b4e4ba8.jpg?v=1779720235","url":"https:\/\/mycircuitbreakers.com\/products\/abb-ge-thql1130gfep-30-amp-1-pole-ground-fault-equipment-protection-circuit-breaker-thql-q-line-120-240v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}