{"product_id":"abb-ge-thql1130gft2-30-amp-1-pole-gfci-circuit-breaker-thql-q-line-120v-ac","title":"ABB \/ GE THQL1130GFT2 30 Amp 1 Pole GFCI Circuit Breaker – THQL Q-Line – 120V AC","description":"\u003cp data-start=\"107\" data-end=\"567\"\u003eThe ABB \/ GE THQL1130GFT2 is a 30 Amp, 1-pole Ground Fault Circuit Interrupter (GFCI) circuit breaker designed to provide personnel protection against ground faults in residential and commercial electrical systems. As part of the THQL Q-Line family, this breaker combines thermal-magnetic overcurrent protection with Class A ground fault protection. It is intended for installation in compatible GE load centers and panelboards using a plug-in mounting design.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"574\" data-end=\"596\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"597\" data-end=\"768\"\u003e\n\u003cli data-section-id=\"l4zkeo\" data-start=\"597\" data-end=\"624\"\u003eCurrent Rating: 30 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"10yua7k\" data-start=\"625\" data-end=\"652\"\u003eVoltage Rating: 120 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"adzwuk\" data-start=\"653\" data-end=\"675\"\u003eNumber of Poles: 1\u003c\/li\u003e\n\u003cli data-section-id=\"1epuro4\" data-start=\"676\" data-end=\"718\"\u003eInterrupting Rating: 10 kAIC @ 120 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1ghuaec\" data-start=\"719\" data-end=\"768\"\u003eDevice Type: GFCI Circuit Breaker (Self-Test)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"775\" data-end=\"797\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"798\" data-end=\"997\"\u003e\n\u003cli data-section-id=\"1pa8my\" data-start=\"798\" data-end=\"821\"\u003eSeries: THQL Q-Line\u003c\/li\u003e\n\u003cli data-section-id=\"1i47q9v\" data-start=\"822\" data-end=\"851\"\u003ePart Number: THQL1130GFT2\u003c\/li\u003e\n\u003cli data-section-id=\"6t9q2m\" data-start=\"852\" data-end=\"892\"\u003eManufacturer: ABB \/ General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1ygjdp\" data-start=\"893\" data-end=\"948\"\u003eBreaker Type: Thermal Magnetic with GFCI protection\u003c\/li\u003e\n\u003cli data-section-id=\"1kkh616\" data-start=\"949\" data-end=\"976\"\u003eMounting Style: Plug-On\u003c\/li\u003e\n\u003cli data-section-id=\"sbdk2e\" data-start=\"977\" data-end=\"997\"\u003eFrame Type: THQL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1004\" data-end=\"1032\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1033\" data-end=\"1422\"\u003e\n\u003cli data-section-id=\"1amudj5\" data-start=\"1033\" data-end=\"1155\"\u003eProtection Functions:\n\u003cul data-start=\"1061\" data-end=\"1155\"\u003e\n\u003cli data-section-id=\"14s7m03\" data-start=\"1061\" data-end=\"1084\"\u003eOverload protection\u003c\/li\u003e\n\u003cli data-section-id=\"xnufhj\" data-start=\"1087\" data-end=\"1115\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"oxsk5m\" data-start=\"1118\" data-end=\"1155\"\u003eGround fault protection (Class A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1156\" data-end=\"1193\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1c17alg\" data-start=\"1194\" data-end=\"1223\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"1lohe01\" data-start=\"1224\" data-end=\"1422\"\u003eConstruction Features:\n\u003cul data-start=\"1253\" data-end=\"1422\"\u003e\n\u003cli data-section-id=\"1m8d4cc\" data-start=\"1253\" data-end=\"1322\"\u003eSelf-test capability (as indicated by updated GFT2 design family)\u003c\/li\u003e\n\u003cli data-section-id=\"1mdxkn5\" data-start=\"1325\" data-end=\"1361\"\u003eQuick-make\/quick-break mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1aya9bc\" data-start=\"1364\" data-end=\"1386\"\u003eCommon trip design\u003c\/li\u003e\n\u003cli data-section-id=\"ho0sak\" data-start=\"1389\" data-end=\"1422\"\u003eCompact plug-on Q-Line format\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1429\" data-end=\"1456\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1457\" data-end=\"1522\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"1457\" data-end=\"1470\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"1471\" data-end=\"1488\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1bykqv\" data-start=\"1489\" data-end=\"1522\"\u003eNEC compliant GFCI protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1529\" data-end=\"1545\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1546\" data-end=\"1718\"\u003e\n\u003cli data-section-id=\"1ciznif\" data-start=\"1546\" data-end=\"1578\"\u003eCatalog Number: THQL1130GFT2\u003c\/li\u003e\n\u003cli data-section-id=\"m779yb\" data-start=\"1579\" data-end=\"1608\"\u003eMfr. Number: THQL1130GFT2\u003c\/li\u003e\n\u003cli data-section-id=\"1pa8my\" data-start=\"1609\" data-end=\"1632\"\u003eSeries: THQL Q-Line\u003c\/li\u003e\n\u003cli data-section-id=\"1d5padt\" data-start=\"1633\" data-end=\"1671\"\u003eProduct Type: GFCI Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1q9htk9\" data-start=\"1672\" data-end=\"1718\"\u003eUnit Weight: ~217 g (per supplier listing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1725\" data-end=\"1741\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1742\" data-end=\"1989\"\u003e\n\u003cli data-section-id=\"g1wlzy\" data-start=\"1742\" data-end=\"1783\"\u003eResidential branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"x88ua4\" data-start=\"1784\" data-end=\"1827\"\u003eKitchen, bathroom, and laundry circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1g3atey\" data-start=\"1828\" data-end=\"1862\"\u003eCommercial receptacle circuits\u003c\/li\u003e\n\u003cli data-section-id=\"upq08z\" data-start=\"1863\" data-end=\"1899\"\u003eDamp and wet location protection\u003c\/li\u003e\n\u003cli data-section-id=\"9zfa8\" data-start=\"1900\" data-end=\"1946\"\u003ePersonnel ground fault safety applications\u003c\/li\u003e\n\u003cli data-section-id=\"13nb6tu\" data-start=\"1947\" data-end=\"1989\"\u003eGE Q-Line load centers and panelboards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48445114843385,"sku":"THQL1130GFT2","price":75.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000273163_400x400_ac5aa92f-6af4-4073-a541-d82851e6ccb4.jpg?v=1779720503","url":"https:\/\/mycircuitbreakers.com\/products\/abb-ge-thql1130gft2-30-amp-1-pole-gfci-circuit-breaker-thql-q-line-120v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}