{"product_id":"abb-xt1su3100afd000xxx-100a-3p-molded-case-circuit-breaker-xt1-series-thermal-magnetic-35ka-480v","title":"ABB XT1SU3100AFD000XXX 100A 3P Molded Case Circuit Breaker – XT1 Series – Thermal Magnetic – 35kA @ 480V","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69eb4d5f-7fa0-83e8-afae-2e87d51a4210-22\" data-testid=\"conversation-turn-270\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"1c5a1767-4442-4b40-96f9-336f7a949991\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word dark markdown-new-styling\"\u003e\n\u003cp data-start=\"152\" data-end=\"502\"\u003eThe ABB XT1SU3100AFD000XXX is a 100A, 3-pole molded case circuit breaker from the SACE Tmax XT1 family, designed for commercial and industrial electrical distribution systems. It provides dependable overcurrent protection using a fixed thermal-magnetic trip unit, delivering both long-time and instantaneous (LI) protection.\u003c\/p\u003e\n\u003cp data-start=\"504\" data-end=\"746\"\u003eThis unit-mount breaker is engineered for installation in ABB SACE Tmax XT panelboards and compatible switchboards. It is suitable for replacing legacy Tmax T1 series breakers while maintaining consistent system performance and compatibility.\u003c\/p\u003e\n\u003cp data-start=\"748\" data-end=\"886\"\u003eWith a 35kA interrupting rating at 480VAC, the XT1SU3100AFD000XXX offers strong fault-clearing capability in compact distribution systems.\u003c\/p\u003e\n\u003cp data-start=\"893\" data-end=\"915\"\u003e\u003cstrong data-start=\"893\" data-end=\"915\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"917\" data-end=\"1099\"\u003e\n\u003cli data-section-id=\"8dkgdn\" data-start=\"917\" data-end=\"942\"\u003eCurrent Rating: 100 A\u003c\/li\u003e\n\u003cli data-section-id=\"9u35uc\" data-start=\"943\" data-end=\"998\"\u003eVoltage Rating: 240VAC, 480VAC, 600Y\/347VAC, 250VDC\u003c\/li\u003e\n\u003cli data-section-id=\"w7zpea\" data-start=\"999\" data-end=\"1099\"\u003eAIC Rating:\n\u003cul data-start=\"1017\" data-end=\"1099\"\u003e\n\u003cli data-section-id=\"r1iv8\" data-start=\"1017\" data-end=\"1034\"\u003e65kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1vwgnt7\" data-start=\"1037\" data-end=\"1054\"\u003e35kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"14couht\" data-start=\"1057\" data-end=\"1079\"\u003e22kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1v29yv9\" data-start=\"1082\" data-end=\"1099\"\u003e42kA @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1106\" data-end=\"1128\"\u003e\u003cstrong data-start=\"1106\" data-end=\"1128\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1130\" data-end=\"1510\"\u003e\n\u003cli data-section-id=\"1vhb1f5\" data-start=\"1130\" data-end=\"1174\"\u003eDevice Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"aroaz7\" data-start=\"1175\" data-end=\"1190\"\u003eSeries: XT1\u003c\/li\u003e\n\u003cli data-section-id=\"bad5e\" data-start=\"1191\" data-end=\"1218\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"1219\" data-end=\"1237\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1b3baop\" data-start=\"1238\" data-end=\"1275\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"yw5yr0\" data-start=\"1276\" data-end=\"1322\"\u003eProtection: Fixed Thermal \/ Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"ue0akg\" data-start=\"1323\" data-end=\"1349\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"1myj8em\" data-start=\"1350\" data-end=\"1393\"\u003eTrip Function: Long-Time, Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"pl9r6s\" data-start=\"1394\" data-end=\"1424\"\u003eMounting Style: Unit Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1nbdjus\" data-start=\"1425\" data-end=\"1448\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"1x2ntui\" data-start=\"1449\" data-end=\"1510\"\u003eApplication: Commercial and industrial power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1517\" data-end=\"1545\"\u003e\u003cstrong data-start=\"1517\" data-end=\"1545\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1547\" data-end=\"1874\"\u003e\n\u003cli data-section-id=\"7nocsp\" data-start=\"1547\" data-end=\"1587\"\u003eWire Range: 10 AWG – 2\/0 AWG (Cu\/Al)\u003c\/li\u003e\n\u003cli data-section-id=\"bqw95g\" data-start=\"1588\" data-end=\"1609\"\u003eMax Wire: 2\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1u5wzfq\" data-start=\"1610\" data-end=\"1630\"\u003eMin Wire: 10 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"fzwkp4\" data-start=\"1631\" data-end=\"1668\"\u003eTemperature Rating: -25°C to 70°C\u003c\/li\u003e\n\u003cli data-section-id=\"jkk3me\" data-start=\"1669\" data-end=\"1714\"\u003eDimensions (HxWxD): 5.12\" x 3.00\" x 2.76\"\u003c\/li\u003e\n\u003cli data-section-id=\"u9hh40\" data-start=\"1715\" data-end=\"1734\"\u003eWeight: 2.4 lbs\u003c\/li\u003e\n\u003cli data-section-id=\"1cpryz3\" data-start=\"1735\" data-end=\"1822\"\u003eConstruction Features: Current Limiting, Double Insulated, Reverse Feed, HACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"11s84x5\" data-start=\"1823\" data-end=\"1874\"\u003eStandards: CSA C22.2 No. 5, IEC 60947-2, UL 489\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1881\" data-end=\"1897\"\u003e\u003cstrong data-start=\"1881\" data-end=\"1897\"\u003eProduct Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1899\" data-end=\"2101\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1wvqgrn\" data-start=\"1899\" data-end=\"1920\"\u003eManufacturer: ABB\u003c\/li\u003e\n\u003cli data-section-id=\"1dry2x7\" data-start=\"1921\" data-end=\"1957\"\u003eModel Number: XT1SU3100AFD000XXX\u003c\/li\u003e\n\u003cli data-section-id=\"j71r1s\" data-start=\"1958\" data-end=\"1997\"\u003eProduct Series: XT1 (SACE Tmax XT1)\u003c\/li\u003e\n\u003cli data-section-id=\"3lu06y\" data-start=\"1998\" data-end=\"2031\"\u003eInstallation Type: Unit Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1ge269b\" data-start=\"2032\" data-end=\"2101\" data-is-last-node=\"\"\u003eCompatible Equipment: ABB SACE Tmax XT Panelboards and Switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"ABB","offers":[{"title":"NEW","offer_id":48337451647225,"sku":"XT1SU3100AFD000XXX","price":585.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/OOO_d366a368-d328-4872-9b1f-91981a213612.webp?v=1777561669","url":"https:\/\/mycircuitbreakers.com\/products\/abb-xt1su3100afd000xxx-100a-3p-molded-case-circuit-breaker-xt1-series-thermal-magnetic-35ka-480v","provider":"My Circuit Breakers","version":"1.0","type":"link"}