{"product_id":"eaton-brn130gf-br-gfci-circuit-breaker-30a-single-pole-120-240v","title":"Eaton BRN130GF BR GFCI Circuit Breaker – 30A, Single-Pole, 120\/240V","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a02164e-d728-83e9-913c-2b016ff57229-8\" data-turn-id-container=\"request-6a02164e-d728-83e9-913c-2b016ff57229-8\" data-testid=\"conversation-turn-156\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"41922e29-48b4-41dc-9912-1ca70b26f808\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"126\" data-end=\"530\"\u003eThe Eaton BRN130GF GFCI circuit breaker provides reliable personnel and equipment protection against ground fault conditions in electrical systems. This single-pole 30A breaker features 5 mA ground fault protection with a trip-to-center indicator for easy trip identification. Designed with a plug-on connection, it allows quick installation in compatible Eaton BRN loadcenters.\u003c\/p\u003e\n\u003cp data-start=\"537\" data-end=\"559\"\u003e\u003cstrong data-start=\"537\" data-end=\"559\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"561\" data-end=\"811\"\u003e\n\u003cli data-section-id=\"7spoqh\" data-start=\"561\" data-end=\"584\"\u003eCurrent Rating: 30A\u003c\/li\u003e\n\u003cli data-section-id=\"hiuh3g\" data-start=\"585\" data-end=\"613\"\u003eVoltage Rating: 120\/240V\u003c\/li\u003e\n\u003cli data-section-id=\"13m4ppw\" data-start=\"614\" data-end=\"643\"\u003eInterrupt Rating: 10 kAIC\u003c\/li\u003e\n\u003cli data-section-id=\"1mno5yz\" data-start=\"644\" data-end=\"676\"\u003eNumber of Poles: Single-pole\u003c\/li\u003e\n\u003cli data-section-id=\"hs9pul\" data-start=\"677\" data-end=\"706\"\u003eTrip Type: Trip-to-center\u003c\/li\u003e\n\u003cli data-section-id=\"ffcwy1\" data-start=\"707\" data-end=\"763\"\u003eCircuit Protection: Ground fault circuit interrupter\u003c\/li\u003e\n\u003cli data-section-id=\"1tvfopl\" data-start=\"764\" data-end=\"790\"\u003eProtection Level: 5 mA\u003c\/li\u003e\n\u003cli data-section-id=\"1omyw6n\" data-start=\"791\" data-end=\"811\"\u003eTrip Rating: 30A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"818\" data-end=\"840\"\u003e\u003cstrong data-start=\"818\" data-end=\"840\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"842\" data-end=\"1171\"\u003e\n\u003cli data-section-id=\"104z54j\" data-start=\"842\" data-end=\"865\"\u003eManufacturer: Eaton\u003c\/li\u003e\n\u003cli data-section-id=\"4xgnhk\" data-start=\"866\" data-end=\"894\"\u003eCatalog Number: BRN130GF\u003c\/li\u003e\n\u003cli data-section-id=\"295e71\" data-start=\"895\" data-end=\"916\"\u003eUPC: 786689031435\u003c\/li\u003e\n\u003cli data-section-id=\"1jc2hva\" data-start=\"917\" data-end=\"955\"\u003eProduct Type: GFCI circuit breaker\u003c\/li\u003e\n\u003cli data-section-id=\"4fyl5p\" data-start=\"956\" data-end=\"1002\"\u003eType: Plug-in ground fault circuit breaker\u003c\/li\u003e\n\u003cli data-section-id=\"15qve9n\" data-start=\"1003\" data-end=\"1032\"\u003eMain Circuit Breaker: BRN\u003c\/li\u003e\n\u003cli data-section-id=\"1fqe1r5\" data-start=\"1033\" data-end=\"1056\"\u003eConnection: Plug-on\u003c\/li\u003e\n\u003cli data-section-id=\"76edh\" data-start=\"1057\" data-end=\"1085\"\u003eMounting Method: Plug-on\u003c\/li\u003e\n\u003cli data-section-id=\"1esktdx\" data-start=\"1086\" data-end=\"1110\"\u003eWire Size: #14–8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1kzphn3\" data-start=\"1111\" data-end=\"1130\"\u003eIndicators: GFI\u003c\/li\u003e\n\u003cli data-section-id=\"a76top\" data-start=\"1131\" data-end=\"1171\"\u003eCertifications: Contact Manufacturer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1178\" data-end=\"1198\"\u003e\u003cstrong data-start=\"1178\" data-end=\"1198\"\u003ePhysical Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1200\" data-end=\"1309\"\u003e\n\u003cli data-section-id=\"1tdyfdf\" data-start=\"1200\" data-end=\"1230\"\u003eProduct Length\/Depth: 4 in\u003c\/li\u003e\n\u003cli data-section-id=\"7qlptj\" data-start=\"1231\" data-end=\"1255\"\u003eProduct Height: 1 in\u003c\/li\u003e\n\u003cli data-section-id=\"hsccuu\" data-start=\"1256\" data-end=\"1281\"\u003eProduct Width: 3.4 in\u003c\/li\u003e\n\u003cli data-section-id=\"12yaszz\" data-start=\"1282\" data-end=\"1309\"\u003eProduct Weight: 0.45 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1316\" data-end=\"1332\"\u003e\u003cstrong data-start=\"1316\" data-end=\"1332\"\u003eProduct Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1334\" data-end=\"1544\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"19m5ea8\" data-start=\"1334\" data-end=\"1398\"\u003eApplication: Ground fault personnel and equipment protection\u003c\/li\u003e\n\u003cli data-section-id=\"s7syh6\" data-start=\"1399\" data-end=\"1439\"\u003eCompatibility: Eaton BRN loadcenters\u003c\/li\u003e\n\u003cli data-section-id=\"uucgqn\" data-start=\"1440\" data-end=\"1474\"\u003eMounting Style: Plug-on design\u003c\/li\u003e\n\u003cli data-section-id=\"wonrjf\" data-start=\"1475\" data-end=\"1544\" data-is-last-node=\"\"\u003eProtection Type: Ground fault circuit interrupter (GFCI) protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"NEW","offer_id":48395464212729,"sku":"BRN130GF","price":79.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/BRN130GF_C.jpg?v=1778606863","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-brn130gf-br-gfci-circuit-breaker-30a-single-pole-120-240v","provider":"My Circuit Breakers","version":"1.0","type":"link"}