{"product_id":"eaton-cutler-hammer-crd316t33w-1600a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"Eaton Cutler-Hammer CRD316T33W 1600A 3 Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-start=\"151\" data-end=\"503\"\u003eThe Eaton Cutler-Hammer CRD316T33W molded case circuit breaker is engineered for high-capacity electrical distribution systems in industrial and commercial facilities. Built on the durable R-Frame platform, this breaker incorporates the Digitrip RMS 310 electronic trip unit, providing reliable protection against overload and short-circuit conditions.\u003c\/p\u003e\n\u003cp data-start=\"505\" data-end=\"855\"\u003eIts adjustable long-delay and short-delay protection functions allow system designers to configure protection parameters for better coordination with other protective devices. With a 1600-amp rating and strong interrupting capability, this circuit breaker is suitable for heavy-duty power systems where dependable performance and safety are critical.\u003c\/p\u003e\n\u003ch4 data-start=\"862\" data-end=\"888\"\u003eVoltage and Ratings\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"891\" data-end=\"924\"\u003eRated Current: \u003cstrong data-start=\"906\" data-end=\"922\"\u003e1600 Amperes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"927\" data-end=\"961\"\u003eRated Voltage: \u003cstrong data-start=\"942\" data-end=\"959\"\u003eUp to 600 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"989\"\u003eFrequency: \u003cstrong data-start=\"975\" data-end=\"987\"\u003e50\/60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"992\" data-end=\"1016\"\u003eInterrupting Capacity:\n\u003cul\u003e\n\u003cli\u003e\u003cstrong data-start=\"1021\" data-end=\"1042\"\u003e125 kA at 240 VAC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1049\" data-end=\"1071\"\u003e\u003cstrong data-start=\"1049\" data-end=\"1069\"\u003e65 kA at 480 VAC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1076\" data-end=\"1098\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1096\"\u003e50 kA at 600 VAC\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v25719\" data-start=\"1099\" data-end=\"1140\"\u003e\n\u003cp data-start=\"1101\" data-end=\"1140\"\u003eTemperature Rating: \u003cstrong data-start=\"1121\" data-end=\"1138\"\u003e1600A at 40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1edvawt\" data-start=\"1141\" data-end=\"1177\"\u003e\n\u003cp data-start=\"1143\" data-end=\"1177\"\u003eApplication Rating: \u003cstrong data-start=\"1163\" data-end=\"1177\"\u003e100% Rated\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1184\" data-end=\"1209\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1212\" data-end=\"1284\"\u003e\n\u003cstrong data-start=\"1212\" data-end=\"1253\"\u003eDigitrip RMS 310 electronic trip unit\u003c\/strong\u003e for accurate fault detection\u003c\/li\u003e\n\u003cli data-start=\"1287\" data-end=\"1345\"\u003e\n\u003cstrong data-start=\"1287\" data-end=\"1314\"\u003eLS protection functions\u003c\/strong\u003e (Long Delay and Short Delay)\u003c\/li\u003e\n\u003cli data-start=\"1348\" data-end=\"1410\"\u003eAdjustable long-delay pickup using rating plug configuration\u003c\/li\u003e\n\u003cli data-start=\"1413\" data-end=\"1474\"\u003eShort-delay pickup with selectable response characteristics\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1546\"\u003eDesigned for reliable protection of high-power distribution systems\u003c\/li\u003e\n\u003cli data-start=\"1549\" data-end=\"1610\"\u003eCompatible with optional accessories for system customization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1617\" data-end=\"1648\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1651\" data-end=\"1705\"\u003eBreaker Type: \u003cstrong data-start=\"1665\" data-end=\"1703\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1708\" data-end=\"1738\"\u003eModel Number: \u003cstrong data-start=\"1722\" data-end=\"1736\"\u003eCRD316T33W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1741\" data-end=\"1766\"\u003eFrame Type: \u003cstrong data-start=\"1753\" data-end=\"1764\"\u003eR Frame\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1769\" data-end=\"1835\"\u003eTrip Unit: \u003cstrong data-start=\"1780\" data-end=\"1833\"\u003eElectronic Non-Interchangeable (Digitrip RMS 310)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1838\" data-end=\"1888\"\u003eTrip Functions: \u003cstrong data-start=\"1854\" data-end=\"1886\"\u003eLS (Long Delay, Short Delay)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1891\" data-end=\"1947\"\u003eShort Delay Response Options: \u003cstrong data-start=\"1921\" data-end=\"1945\"\u003eI²t or flat response\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1950\" data-end=\"2006\"\u003eTrip Setting Range: \u003cstrong data-start=\"1970\" data-end=\"2004\"\u003e2–8 × Continuous Ampere Rating\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2009\" data-end=\"2038\"\u003eNumber of Poles: \u003cstrong data-start=\"2026\" data-end=\"2036\"\u003e3 Pole\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2071\"\u003eConnection Type: \u003cstrong data-start=\"2058\" data-end=\"2069\"\u003eBolt-On\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2074\" data-end=\"2113\"\u003eMounting Type: \u003cstrong data-start=\"2089\" data-end=\"2113\"\u003eBolt-On Installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"2120\" data-end=\"2139\"\u003eProduct Data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"2142\" data-end=\"2183\"\u003eManufacturer: \u003cstrong data-start=\"2156\" data-end=\"2181\"\u003eEaton \/ Cutler-Hammer\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2186\" data-end=\"2203\"\u003eSeries: \u003cstrong data-start=\"2194\" data-end=\"2201\"\u003eCRD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2206\" data-end=\"2232\"\u003eRated Current: \u003cstrong data-start=\"2221\" data-end=\"2230\"\u003e1600A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2235\" data-end=\"2264\"\u003eMaximum Voltage: \u003cstrong data-start=\"2252\" data-end=\"2262\"\u003e600VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2267\" data-end=\"2287\"\u003eWarranty: \u003cstrong data-start=\"2277\" data-end=\"2287\"\u003e1 Year\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2289\" data-end=\"2578\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2289\" data-end=\"2303\"\u003eImportant:\u003c\/strong\u003e This breaker requires a \u003cstrong data-start=\"2328\" data-end=\"2354\"\u003ecompatible rating plug\u003c\/strong\u003e for proper operation. Ensure the correct rating plug is installed based on the required protection settings. Accessories ordered with the breaker can be configured during installation to match your application requirements.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Recondition","offer_id":47482472235257,"sku":"CRD316T33W","price":5499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/rd_1_29_39_e388a22e-b3ba-4be9-adee-2c3a8966b633.jpg?v=1772800760","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-crd316t33w-1600a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}