{"product_id":"eaton-cutler-hammer-e2m3600w-600a-3-pole-molded-case-mining-circuit-breaker-bolt-on-600vac","title":"Eaton Cutler Hammer E2M3600W 600A 3 Pole Molded Case Mining Circuit Breaker – Bolt On – 600VAC","description":"\u003cp data-start=\"140\" data-end=\"770\"\u003eThe Eaton Cutler Hammer E2M3600W is a heavy-duty molded case mining circuit breaker designed for demanding industrial and mining power distribution systems. Built with an interchangeable thermal-magnetic trip unit, this 600 amp breaker provides dependable overload and short-circuit protection for critical electrical equipment. Its rugged bolt-on mounting design ensures secure installation, while the 3-pole configuration makes it ideal for three-phase applications operating up to 600VAC. Engineered for durability and performance, this breaker is suitable for harsh environments where reliable circuit protection is essential.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wc2bmo\" data-start=\"772\" data-end=\"799\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul data-start=\"800\" data-end=\"1144\"\u003e\n\u003cli data-section-id=\"el4ink\" data-start=\"800\" data-end=\"832\"\u003eBrand: Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-section-id=\"9km9va\" data-start=\"833\" data-end=\"859\"\u003eModel Number: E2M3600W\u003c\/li\u003e\n\u003cli data-section-id=\"tprfe8\" data-start=\"860\" data-end=\"881\"\u003eAmperage: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"1mjvejc\" data-start=\"882\" data-end=\"909\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1uagnpo\" data-start=\"910\" data-end=\"962\"\u003eBreaker Type: Molded Case Mining Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"4edz77\" data-start=\"963\" data-end=\"986\"\u003eMount Type: Bolt On\u003c\/li\u003e\n\u003cli data-section-id=\"1sd9s71\" data-start=\"987\" data-end=\"1017\"\u003eFrame Style: E2M \/ M Frame\u003c\/li\u003e\n\u003cli data-section-id=\"rh7f1f\" data-start=\"1018\" data-end=\"1070\"\u003eTrip Unit Type: Interchangeable Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1071\" data-end=\"1094\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1p6vay7\" data-start=\"1095\" data-end=\"1144\"\u003eStandard Lug Type: Without Terminals Standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1146\" data-end=\"1175\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1176\" data-end=\"1557\"\u003e\n\u003cli data-section-id=\"bc2qbu\" data-start=\"1176\" data-end=\"1249\"\u003eThermal-magnetic protection for overload and short circuit conditions\u003c\/li\u003e\n\u003cli data-section-id=\"fmueqm\" data-start=\"1250\" data-end=\"1312\"\u003eInterchangeable trip unit for flexible system requirements\u003c\/li\u003e\n\u003cli data-section-id=\"lbtfj6\" data-start=\"1313\" data-end=\"1380\"\u003eHeavy-duty molded case construction for industrial environments\u003c\/li\u003e\n\u003cli data-section-id=\"1gvxfie\" data-start=\"1381\" data-end=\"1423\"\u003eBolt-on connection for secure mounting\u003c\/li\u003e\n\u003cli data-section-id=\"1lj8p82\" data-start=\"1424\" data-end=\"1461\"\u003eRated operating temperature: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"2cvr62\" data-start=\"1462\" data-end=\"1521\"\u003eDesigned for mining and industrial distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"4trdf4\" data-start=\"1522\" data-end=\"1557\"\u003eTrip Setting Range: 1500 – 3000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11flra0\" data-start=\"1559\" data-end=\"1583\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-start=\"1584\" data-end=\"1801\"\u003e\n\u003cli data-section-id=\"xbwqhm\" data-start=\"1584\" data-end=\"1612\"\u003eMaximum Voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"yx5c53\" data-start=\"1613\" data-end=\"1639\"\u003eRated Current: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"18sr2bu\" data-start=\"1640\" data-end=\"1681\"\u003eInterrupting Capacity: 65 kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"rjdg8f\" data-start=\"1682\" data-end=\"1728\"\u003eInterrupting Capacity: 35 \/ 50 kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1a6zbta\" data-start=\"1729\" data-end=\"1770\"\u003eInterrupting Capacity: 25 kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5wq7\" data-start=\"1771\" data-end=\"1801\"\u003eFrequency Rating: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"165x1by\" data-start=\"1803\" data-end=\"1820\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"1821\" data-end=\"2206\"\u003e\n\u003cli data-section-id=\"qqivss\" data-start=\"1821\" data-end=\"1895\"\u003eCondition: New \/ Surplus \/ Reconditioned (depending on supplier stock)\u003c\/li\u003e\n\u003cli data-section-id=\"1pruqjc\" data-start=\"1896\" data-end=\"1916\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003cli data-section-id=\"ef7yl1\" data-start=\"1917\" data-end=\"1965\"\u003eProduct Category: Industrial Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"ocs6ns\" data-start=\"1966\" data-end=\"2053\"\u003eSuitable Applications: Mining, Heavy Industry, Power Distribution, Motor Protection\u003c\/li\u003e\n\u003cli data-section-id=\"11205e6\" data-start=\"2054\" data-end=\"2095\"\u003eManufacturer Series: Eaton E2M Series\u003c\/li\u003e\n\u003cli data-section-id=\"o0hedk\" data-start=\"2096\" data-end=\"2124\"\u003eConnection Type: Bolt On\u003c\/li\u003e\n\u003cli data-section-id=\"1o9uwhk\" data-start=\"2125\" data-end=\"2206\"\u003eAccessory Installation: Available at no additional cost when ordered together\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2208\" data-end=\"2227\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2228\" data-end=\"2503\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eProduct image may represent a base model and is for identification purposes only. Accessories can often be installed before shipment when ordered together. Always confirm compatibility, trip settings, terminal requirements, and system voltage before installation or purchase.\u003c\/p\u003e","brand":"Eaton Cutler Hammer Mining","offers":[{"title":"Certified Reconditioned","offer_id":48325352194297,"sku":"E2M3600W","price":7499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/E2M3600W.webp?v=1777273164","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-e2m3600w-600a-3-pole-molded-case-mining-circuit-breaker-bolt-on-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}