{"product_id":"eaton-cutler-hammer-e2m3600wa06u66-600a-3-pole-molded-case-mining-circuit-breaker-bolt-on-600vac","title":"Eaton Cutler Hammer E2M3600WA06U66 600A 3 Pole Molded Case Mining Circuit Breaker – Bolt On – 600VAC","description":"\u003cdiv class=\"\" data-turn-id-container=\"request-WEB:1a59adb1-7f38-4b4c-b06a-37ebd6337a73-3\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:1a59adb1-7f38-4b4c-b06a-37ebd6337a73-3\" data-testid=\"conversation-turn-8\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"ded0909a-eea3-46aa-82d5-eae62e16f8e9\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word dark markdown-new-styling\"\u003e\n\u003cp data-start=\"146\" data-end=\"799\"\u003eThe Eaton Cutler Hammer E2M3600WA06U66 is a high-performance molded case mining circuit breaker built for demanding industrial and mining electrical systems. Rated at 600 amps with a 3-pole design, this breaker features an interchangeable thermal-magnetic trip unit for dependable overload and short-circuit protection. It includes the A06 auxiliary switch option for remote status indication and the U66 undervoltage release option with LED indicator for enhanced system safety and control. Designed with a secure bolt-on connection and rated for operation up to 600VAC, this breaker is ideal for heavy-duty three-phase power distribution applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wc2bmo\" data-start=\"801\" data-end=\"828\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul data-start=\"829\" data-end=\"1234\"\u003e\n\u003cli data-section-id=\"el4ink\" data-start=\"829\" data-end=\"861\"\u003eBrand: Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-section-id=\"vvxouc\" data-start=\"862\" data-end=\"894\"\u003eModel Number: E2M3600WA06U66\u003c\/li\u003e\n\u003cli data-section-id=\"tprfe8\" data-start=\"895\" data-end=\"916\"\u003eAmperage: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"1mjvejc\" data-start=\"917\" data-end=\"944\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1uagnpo\" data-start=\"945\" data-end=\"997\"\u003eBreaker Type: Molded Case Mining Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"4edz77\" data-start=\"998\" data-end=\"1021\"\u003eMount Type: Bolt On\u003c\/li\u003e\n\u003cli data-section-id=\"1sd9s71\" data-start=\"1022\" data-end=\"1052\"\u003eFrame Style: E2M \/ M Frame\u003c\/li\u003e\n\u003cli data-section-id=\"rh7f1f\" data-start=\"1053\" data-end=\"1105\"\u003eTrip Unit Type: Interchangeable Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1106\" data-end=\"1129\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1llajjz\" data-start=\"1130\" data-end=\"1184\"\u003eConfiguration: A06 + U66 Factory Installed Options\u003c\/li\u003e\n\u003cli data-section-id=\"1p6vay7\" data-start=\"1185\" data-end=\"1234\"\u003eStandard Lug Type: Without Terminals Standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1236\" data-end=\"1265\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1266\" data-end=\"1900\"\u003e\n\u003cli data-section-id=\"16gb4fp\" data-start=\"1266\" data-end=\"1344\"\u003eThermal-magnetic trip protection for overload and short circuit conditions\u003c\/li\u003e\n\u003cli data-section-id=\"bzgnyw\" data-start=\"1345\" data-end=\"1411\"\u003eInterchangeable trip unit for flexible protection requirements\u003c\/li\u003e\n\u003cli data-section-id=\"13vkgeb\" data-start=\"1412\" data-end=\"1490\"\u003eHeavy-duty molded case construction for mining and industrial environments\u003c\/li\u003e\n\u003cli data-section-id=\"izu60q\" data-start=\"1491\" data-end=\"1541\"\u003eBolt-on mounting for secure panel installation\u003c\/li\u003e\n\u003cli data-section-id=\"uppc6r\" data-start=\"1542\" data-end=\"1580\"\u003eOperating temperature rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"4trdf4\" data-start=\"1581\" data-end=\"1616\"\u003eTrip Setting Range: 1500 – 3000\u003c\/li\u003e\n\u003cli data-section-id=\"5f671g\" data-start=\"1617\" data-end=\"1675\"\u003eA06 Option: 1-A (Open) \/ 1-B (Closed) Auxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"vjv2an\" data-start=\"1676\" data-end=\"1721\"\u003eA06 Mounting Location: Right Pole Mounted\u003c\/li\u003e\n\u003cli data-section-id=\"1an61ul\" data-start=\"1722\" data-end=\"1747\"\u003eA06 Wiring Exit: Rear\u003c\/li\u003e\n\u003cli data-section-id=\"s9a180\" data-start=\"1748\" data-end=\"1798\"\u003eU66 Option: 120 VAC Undervoltage Release (UVR)\u003c\/li\u003e\n\u003cli data-section-id=\"1311xr2\" data-start=\"1799\" data-end=\"1829\"\u003eU66 Includes LED Indicator\u003c\/li\u003e\n\u003cli data-section-id=\"ydddue\" data-start=\"1830\" data-end=\"1874\"\u003eU66 Mounting Location: Left Pole Mounted\u003c\/li\u003e\n\u003cli data-section-id=\"7w9j7z\" data-start=\"1875\" data-end=\"1900\"\u003eU66 Wiring Exit: Rear\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11flra0\" data-start=\"1902\" data-end=\"1926\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-start=\"1927\" data-end=\"2177\"\u003e\n\u003cli data-section-id=\"xbwqhm\" data-start=\"1927\" data-end=\"1955\"\u003eMaximum Voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"yx5c53\" data-start=\"1956\" data-end=\"1982\"\u003eRated Current: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"18sr2bu\" data-start=\"1983\" data-end=\"2024\"\u003eInterrupting Capacity: 65 kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"rjdg8f\" data-start=\"2025\" data-end=\"2071\"\u003eInterrupting Capacity: 35 \/ 50 kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1a6zbta\" data-start=\"2072\" data-end=\"2113\"\u003eInterrupting Capacity: 25 kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5wq7\" data-start=\"2114\" data-end=\"2144\"\u003eFrequency Rating: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1gu0bwh\" data-start=\"2145\" data-end=\"2177\"\u003eUVR Control Voltage: 120 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"165x1by\" data-start=\"2179\" data-end=\"2196\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"2197\" data-end=\"2593\"\u003e\n\u003cli data-section-id=\"x5ijmp\" data-start=\"2197\" data-end=\"2273\"\u003eCondition: New \/ Surplus \/ Reconditioned (subject to stock availability)\u003c\/li\u003e\n\u003cli data-section-id=\"1pruqjc\" data-start=\"2274\" data-end=\"2294\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003cli data-section-id=\"ef7yl1\" data-start=\"2295\" data-end=\"2343\"\u003eProduct Category: Industrial Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"spam0k\" data-start=\"2344\" data-end=\"2446\"\u003eSuitable Applications: Mining Systems, Industrial Panels, Power Distribution, Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"11205e6\" data-start=\"2447\" data-end=\"2488\"\u003eManufacturer Series: Eaton E2M Series\u003c\/li\u003e\n\u003cli data-section-id=\"o0hedk\" data-start=\"2489\" data-end=\"2517\"\u003eConnection Type: Bolt On\u003c\/li\u003e\n\u003cli data-section-id=\"bn3fjf\" data-start=\"2518\" data-end=\"2593\"\u003eInstalled Accessories: Auxiliary Switch + Undervoltage Release with LED\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2595\" data-end=\"2614\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2615\" data-end=\"2901\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eProduct image may represent a standard base model and is for identification purposes only. This unit includes factory-installed A06 and U66 accessory options. Always verify voltage requirements, trip settings, terminal needs, and accessory compatibility before purchase or installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Eaton Cutler Hammer Mining","offers":[{"title":"Certified Reconditioned","offer_id":48325363564793,"sku":"E2M3600WA06U66","price":8199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/E2M3600WA06U66.webp?v=1777273882","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-e2m3600wa06u66-600a-3-pole-molded-case-mining-circuit-breaker-bolt-on-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}