{"product_id":"eaton-cutler-hammer-e2n312mw-1200a-3p-mining-mccb-bolt-on-600vac","title":"Eaton Cutler-Hammer E2N312MW 1200A 3P Mining MCCB – Bolt On – 600VAC","description":"\u003cp data-start=\"111\" data-end=\"667\"\u003eThe Eaton E2N312MW is a rugged molded case mining circuit breaker (MCCB) designed for high-demand industrial and mining applications. Built on the durable E2N frame, this breaker features a non-interchangeable magnetic-only trip unit, providing fast and reliable short-circuit protection without thermal overload protection. Rated at 1200 amperes, it is well-suited for applications where instantaneous fault protection is critical. With high interrupting capacity and robust construction, it ensures dependable performance in harsh operating environments.\u003c\/p\u003e\n\u003ch2 data-section-id=\"193hxb4\" data-start=\"674\" data-end=\"703\"\u003e\u003cstrong data-start=\"677\" data-end=\"703\"\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"706\" data-end=\"736\"\u003eBrand: Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-start=\"739\" data-end=\"756\"\u003eModel: E2N312MW\u003c\/li\u003e\n\u003cli data-start=\"759\" data-end=\"781\"\u003eRated Current: 1200A\u003c\/li\u003e\n\u003cli data-start=\"784\" data-end=\"809\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-start=\"812\" data-end=\"869\"\u003eBreaker Type: Molded Case Mining Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-start=\"872\" data-end=\"920\"\u003eTrip Unit: Magnetic-Only (Non-Interchangeable)\u003c\/li\u003e\n\u003cli data-start=\"923\" data-end=\"947\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"950\" data-end=\"971\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"989\"\u003eFrame Type: N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"996\" data-end=\"1027\"\u003e\u003cstrong data-start=\"999\" data-end=\"1027\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1030\" data-end=\"1055\"\u003eTrip Setting: 1250–5000\u003c\/li\u003e\n\u003cli data-start=\"1058\" data-end=\"1115\"\u003eTrip Function: Instantaneous (Magnetic-Only Protection)\u003c\/li\u003e\n\u003cli data-start=\"1118\" data-end=\"1144\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1147\" data-end=\"1216\"\u003eDesigned for applications requiring fast short-circuit interruption\u003c\/li\u003e\n\u003cli data-start=\"1219\" data-end=\"1274\"\u003eSuitable for heavy-duty mining and industrial systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"hpn9aw\" data-start=\"1281\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1284\" data-end=\"1307\"\u003eVoltage and Ratings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1310\" data-end=\"1345\"\u003eRated Operational Voltage: 600VAC\u003c\/li\u003e\n\u003cli data-start=\"1348\" data-end=\"1372\"\u003eInterrupting Capacity:\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1377\" data-end=\"1393\"\u003e65 kA @ 240VAC\u003c\/li\u003e\n\u003cli data-start=\"1398\" data-end=\"1414\"\u003e50 kA @ 480VAC\u003c\/li\u003e\n\u003cli data-start=\"1419\" data-end=\"1435\"\u003e25 kA @ 600VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"n53vge\" data-start=\"1442\" data-end=\"1461\"\u003e\u003cstrong data-start=\"1445\" data-end=\"1461\"\u003eProduct Data\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1464\" data-end=\"1519\"\u003eApplication: Mining and industrial power distribution\u003c\/li\u003e\n\u003cli data-start=\"1522\" data-end=\"1580\"\u003eStandard Compliance: Industry-standard MCCB requirements\u003c\/li\u003e\n\u003cli data-start=\"1583\" data-end=\"1601\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003cli data-start=\"1604\" data-end=\"1628\"\u003eLug Type: Standard Lug\u003c\/li\u003e\n\u003cli data-start=\"1631\" data-end=\"1680\"\u003eInstallation: Panel-mounted, bolt-on connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1pjndkj\" data-start=\"1687\" data-end=\"1710\"\u003e\u003cstrong data-start=\"1690\" data-end=\"1708\"\u003eImportant Note\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1711\" data-end=\"2269\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThis breaker utilizes a magnetic-only trip unit and does not provide thermal overload protection; ensure it is applied in systems where external overload protection is provided. Product images are for identification purposes only and may not reflect the exact configuration. Accessories ordered with the breaker can be installed prior to shipment at no additional cost—please provide complete configuration details during checkout. Installation must be performed by qualified personnel in accordance with all applicable electrical codes and safety standards.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47562247373049,"sku":"E2N312MW","price":9999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/E2N312MW.webp?v=1774435053","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-e2n312mw-1200a-3p-mining-mccb-bolt-on-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}