{"product_id":"eaton-cutler-hammer-hmdlb3800t32w-800a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"Eaton Cutler Hammer HMDLB3800T32W 800A 3-Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-end=\"934\" data-start=\"147\"\u003eThe \u003cstrong data-end=\"188\" data-start=\"151\"\u003eEaton Cutler-Hammer HMDLB3800T32W\u003c\/strong\u003e molded case circuit breaker is designed for high-performance protection in demanding commercial and industrial power distribution systems. Built on the reliable \u003cstrong data-end=\"370\" data-start=\"350\"\u003eM-frame platform\u003c\/strong\u003e, this breaker features a \u003cstrong data-end=\"470\" data-start=\"396\"\u003enon-interchangeable electronic trip unit with LSI protection functions\u003c\/strong\u003e that provide advanced protection against overloads, short circuits, and instantaneous faults. Rated for up to \u003cstrong data-end=\"604\" data-start=\"581\"\u003e800 amperes at 40°C\u003c\/strong\u003e with a \u003cstrong data-end=\"636\" data-start=\"612\"\u003e3-pole configuration\u003c\/strong\u003e, the breaker supports electrical systems operating at up to \u003cstrong data-end=\"707\" data-start=\"697\"\u003e600VAC\u003c\/strong\u003e. It is also \u003cstrong data-end=\"762\" data-start=\"720\"\u003esuitable for reverse feed applications\u003c\/strong\u003e, offering flexibility in system design. The unit is supplied \u003cstrong data-end=\"871\" data-start=\"824\"\u003ewithout terminals and without a rating plug\u003c\/strong\u003e, allowing customization to match specific system requirements.\u003c\/p\u003e\n\u003ch1 data-end=\"965\" data-start=\"941\" data-section-id=\"nh62sj\"\u003eProduct Specifications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-end=\"1009\" data-start=\"968\"\u003e\n\u003cstrong data-end=\"985\" data-start=\"968\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-end=\"1038\" data-start=\"1012\"\u003e\n\u003cstrong data-end=\"1022\" data-start=\"1012\"\u003eModel:\u003c\/strong\u003e HMDLB3800T32W\u003c\/li\u003e\n\u003cli data-end=\"1083\" data-start=\"1041\"\u003e\n\u003cstrong data-end=\"1061\" data-start=\"1041\"\u003eAmperage Rating:\u003c\/strong\u003e 800 Amperes Maximum\u003c\/li\u003e\n\u003cli data-end=\"1115\" data-start=\"1086\"\u003e\n\u003cstrong data-end=\"1106\" data-start=\"1086\"\u003eNumber of Poles:\u003c\/strong\u003e 3 Pole\u003c\/li\u003e\n\u003cli data-end=\"1165\" data-start=\"1118\"\u003e\n\u003cstrong data-end=\"1135\" data-start=\"1118\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-end=\"1196\" data-start=\"1168\"\u003e\n\u003cstrong data-end=\"1186\" data-start=\"1168\"\u003eMounting Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-end=\"1224\" data-start=\"1199\"\u003e\n\u003cstrong data-end=\"1214\" data-start=\"1199\"\u003eFrame Type:\u003c\/strong\u003e M Frame\u003c\/li\u003e\n\u003cli data-end=\"1305\" data-start=\"1227\"\u003e\n\u003cstrong data-end=\"1246\" data-start=\"1227\"\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Non-Interchangeable Trip Unit (LSI Functions)\u003c\/li\u003e\n\u003cli data-end=\"1333\" data-start=\"1308\"\u003e\n\u003cstrong data-end=\"1322\" data-start=\"1308\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-end=\"1366\" data-start=\"1336\"\u003e\n\u003cstrong data-end=\"1356\" data-start=\"1336\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-end=\"1393\" data-start=\"1369\"\u003e\n\u003cstrong data-end=\"1382\" data-start=\"1369\"\u003eWarranty:\u003c\/strong\u003e One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-end=\"1426\" data-start=\"1400\" data-section-id=\"zjxypn\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-end=\"1495\" data-start=\"1429\"\u003e\n\u003cstrong data-end=\"1448\" data-start=\"1429\"\u003eTrip Functions:\u003c\/strong\u003e LSI (Long Delay, Short Delay, Instantaneous)\u003c\/li\u003e\n\u003cli data-end=\"1553\" data-start=\"1498\"\u003e\n\u003cstrong data-end=\"1524\" data-start=\"1498\"\u003eLong Delay Pickup (L):\u003c\/strong\u003e Adjustable via rating plug\u003c\/li\u003e\n\u003cli data-end=\"1648\" data-start=\"1556\"\u003e\n\u003cstrong data-end=\"1583\" data-start=\"1556\"\u003eShort Delay Pickup (S):\u003c\/strong\u003e Adjustable with fixed I²t response or adjustable flat response\u003c\/li\u003e\n\u003cli data-end=\"1738\" data-start=\"1651\"\u003e\n\u003cstrong data-end=\"1680\" data-start=\"1651\"\u003eInstantaneous Pickup (I):\u003c\/strong\u003e Adjustable by setting short-time delay to instantaneous\u003c\/li\u003e\n\u003cli data-end=\"1817\" data-start=\"1741\"\u003e\n\u003cstrong data-end=\"1764\" data-start=\"1741\"\u003eTrip Setting Range:\u003c\/strong\u003e Adjustable 5–10 times the continuous ampere rating\u003c\/li\u003e\n\u003cli data-end=\"1889\" data-start=\"1820\"\u003e\n\u003cstrong data-end=\"1848\" data-start=\"1820\"\u003eReverse Feed Capability:\u003c\/strong\u003e Suitable for reverse feed applications\u003c\/li\u003e\n\u003cli data-end=\"1932\" data-start=\"1892\"\u003e\n\u003cstrong data-end=\"1925\" data-start=\"1892\"\u003eOperating Temperature Rating:\u003c\/strong\u003e 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-end=\"1960\" data-start=\"1939\" data-section-id=\"1h1dpa3\"\u003eVoltage and Ratings\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-end=\"1997\" data-start=\"1963\"\u003e\n\u003cstrong data-end=\"1981\" data-start=\"1963\"\u003eRated Voltage:\u003c\/strong\u003e Up to 600 VAC\u003c\/li\u003e\n\u003cli data-end=\"2044\" data-start=\"2000\"\u003e\n\u003cstrong data-end=\"2035\" data-start=\"2000\"\u003eInterrupting Capacity @ 240VAC:\u003c\/strong\u003e 100 kA\u003c\/li\u003e\n\u003cli data-end=\"2090\" data-start=\"2047\"\u003e\n\u003cstrong data-end=\"2082\" data-start=\"2047\"\u003eInterrupting Capacity @ 480VAC:\u003c\/strong\u003e 65 kA\u003c\/li\u003e\n\u003cli data-end=\"2136\" data-start=\"2093\"\u003e\n\u003cstrong data-end=\"2128\" data-start=\"2093\"\u003eInterrupting Capacity @ 600VAC:\u003c\/strong\u003e 35 kA\u003c\/li\u003e\n\u003cli data-end=\"2171\" data-start=\"2139\"\u003e\n\u003cstrong data-end=\"2160\" data-start=\"2139\"\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-end=\"2192\" data-start=\"2178\" data-section-id=\"8dxdq5\"\u003eProduct Data\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-end=\"2230\" data-start=\"2195\"\u003e\n\u003cstrong data-end=\"2214\" data-start=\"2195\"\u003eProduct Series:\u003c\/strong\u003e Eaton M-Frame\u003c\/li\u003e\n\u003cli data-end=\"2284\" data-start=\"2233\"\u003e\n\u003cstrong data-end=\"2254\" data-start=\"2233\"\u003eProduct Category:\u003c\/strong\u003e Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-end=\"2317\" data-start=\"2287\"\u003e\n\u003cstrong data-end=\"2307\" data-start=\"2287\"\u003eConnection Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-end=\"2367\" data-start=\"2320\"\u003e\n\u003cstrong data-end=\"2347\" data-start=\"2320\"\u003eTerminal Configuration:\u003c\/strong\u003e Without terminals\u003c\/li\u003e\n\u003cli data-end=\"2426\" data-start=\"2370\"\u003e\n\u003cstrong data-end=\"2386\" data-start=\"2370\"\u003eRating Plug:\u003c\/strong\u003e Not included (required for operation)\u003c\/li\u003e\n\u003cli data-end=\"2523\" data-start=\"2429\"\u003e\n\u003cstrong data-end=\"2456\" data-start=\"2429\"\u003eMounting Compatibility:\u003c\/strong\u003e Designed for compatible Eaton switchgear and distribution panels\u003c\/li\u003e\n\u003cli data-end=\"2631\" data-start=\"2526\"\u003e\n\u003cstrong data-end=\"2553\" data-start=\"2526\"\u003eCondition Availability:\u003c\/strong\u003e New, surplus, or professionally refurbished depending on supplier inventory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-end=\"2656\" data-start=\"2638\" data-section-id=\"gbcsds\"\u003eImportant Note\u003c\/h1\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"3200\" data-start=\"2657\"\u003eThis circuit breaker \u003cstrong data-end=\"2716\" data-start=\"2678\"\u003erequires a rating plug to function\u003c\/strong\u003e, which is not included with the unit. A compatible rating plug must be installed to set the long delay pickup and determine the breaker’s operational current rating. The breaker is also supplied \u003cstrong data-end=\"2933\" data-start=\"2912\"\u003ewithout terminals\u003c\/strong\u003e, allowing configuration based on installation requirements. Product images generally represent a base model and are provided for identification purposes only. Accessories ordered with the breaker may be installed prior to shipment to meet the required configuration.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47488739508473,"sku":"HMDLB3800T32W-CR","price":4499.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47488739541241,"sku":"HMDLB3800T32W-NS","price":6799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HMDLB3800T32W.webp?v=1773015972","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-hmdlb3800t32w-800a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}