{"product_id":"eaton-cutler-hammer-hmdlb3800t35w-800a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"Eaton Cutler Hammer HMDLB3800T35W 800A 3-Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-start=\"147\" data-end=\"965\"\u003eThe \u003cstrong data-start=\"151\" data-end=\"188\"\u003eEaton Cutler-Hammer HMDLB3800T35W\u003c\/strong\u003e molded case circuit breaker is designed to provide advanced electrical protection for demanding commercial and industrial power distribution systems. Built on Eaton’s robust \u003cstrong data-start=\"363\" data-end=\"383\"\u003eM-frame platform\u003c\/strong\u003e, this breaker features a \u003cstrong data-start=\"409\" data-end=\"483\"\u003enon-interchangeable electronic trip unit with LSG protection functions\u003c\/strong\u003e, delivering comprehensive protection against overloads, short circuits, and ground faults. Rated for \u003cstrong data-start=\"585\" data-end=\"614\"\u003eup to 800 amperes at 40°C\u003c\/strong\u003e with a \u003cstrong data-start=\"622\" data-end=\"646\"\u003e3-pole configuration\u003c\/strong\u003e, the breaker supports electrical systems operating at \u003cstrong data-start=\"701\" data-end=\"717\"\u003eup to 600VAC\u003c\/strong\u003e. It is also \u003cstrong data-start=\"730\" data-end=\"772\"\u003esuitable for reverse feed applications\u003c\/strong\u003e, offering flexible installation in modern power systems. The unit is supplied \u003cstrong data-start=\"851\" data-end=\"898\"\u003ewithout terminals and without a rating plug\u003c\/strong\u003e, allowing customization according to specific system requirements.\u003c\/p\u003e\n\u003ch1 data-section-id=\"nh62sj\" data-start=\"972\" data-end=\"996\"\u003eProduct Specifications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-start=\"999\" data-end=\"1040\"\u003e\n\u003cstrong data-start=\"999\" data-end=\"1016\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"1043\" data-end=\"1069\"\u003e\n\u003cstrong data-start=\"1043\" data-end=\"1053\"\u003eModel:\u003c\/strong\u003e HMDLB3800T35W\u003c\/li\u003e\n\u003cli data-start=\"1072\" data-end=\"1114\"\u003e\n\u003cstrong data-start=\"1072\" data-end=\"1092\"\u003eAmperage Rating:\u003c\/strong\u003e 800 Amperes Maximum\u003c\/li\u003e\n\u003cli data-start=\"1117\" data-end=\"1146\"\u003e\n\u003cstrong data-start=\"1117\" data-end=\"1137\"\u003eNumber of Poles:\u003c\/strong\u003e 3 Pole\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1196\"\u003e\n\u003cstrong data-start=\"1149\" data-end=\"1166\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-start=\"1199\" data-end=\"1227\"\u003e\n\u003cstrong data-start=\"1199\" data-end=\"1217\"\u003eMounting Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1255\"\u003e\n\u003cstrong data-start=\"1230\" data-end=\"1245\"\u003eFrame Type:\u003c\/strong\u003e M Frame\u003c\/li\u003e\n\u003cli data-start=\"1258\" data-end=\"1336\"\u003e\n\u003cstrong data-start=\"1258\" data-end=\"1277\"\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Non-Interchangeable Trip Unit (LSG Functions)\u003c\/li\u003e\n\u003cli data-start=\"1339\" data-end=\"1364\"\u003e\n\u003cstrong data-start=\"1339\" data-end=\"1353\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1367\" data-end=\"1397\"\u003e\n\u003cstrong data-start=\"1367\" data-end=\"1387\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"1400\" data-end=\"1424\"\u003e\n\u003cstrong data-start=\"1400\" data-end=\"1413\"\u003eWarranty:\u003c\/strong\u003e One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"1431\" data-end=\"1457\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-start=\"1460\" data-end=\"1525\"\u003e\n\u003cstrong data-start=\"1460\" data-end=\"1479\"\u003eTrip Functions:\u003c\/strong\u003e LSG (Long Delay, Short Delay, Ground Fault)\u003c\/li\u003e\n\u003cli data-start=\"1528\" data-end=\"1583\"\u003e\n\u003cstrong data-start=\"1528\" data-end=\"1554\"\u003eLong Delay Pickup (L):\u003c\/strong\u003e Adjustable via rating plug\u003c\/li\u003e\n\u003cli data-start=\"1586\" data-end=\"1697\"\u003e\n\u003cstrong data-start=\"1586\" data-end=\"1613\"\u003eShort Delay Pickup (S):\u003c\/strong\u003e Adjustable with fixed short delay time (I²t response) or adjustable flat response\u003c\/li\u003e\n\u003cli data-start=\"1700\" data-end=\"1816\"\u003e\n\u003cstrong data-start=\"1700\" data-end=\"1732\"\u003eGround Fault Protection (G):\u003c\/strong\u003e Adjustable ground fault pickup with adjustable ground fault delay (flat response)\u003c\/li\u003e\n\u003cli data-start=\"1819\" data-end=\"1895\"\u003e\n\u003cstrong data-start=\"1819\" data-end=\"1842\"\u003eTrip Setting Range:\u003c\/strong\u003e Adjustable 5–10 times the continuous ampere rating\u003c\/li\u003e\n\u003cli data-start=\"1898\" data-end=\"1967\"\u003e\n\u003cstrong data-start=\"1898\" data-end=\"1926\"\u003eReverse Feed Capability:\u003c\/strong\u003e Suitable for reverse feed applications\u003c\/li\u003e\n\u003cli data-start=\"1970\" data-end=\"2010\"\u003e\n\u003cstrong data-start=\"1970\" data-end=\"2003\"\u003eOperating Temperature Rating:\u003c\/strong\u003e 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1h1dpa3\" data-start=\"2017\" data-end=\"2038\"\u003eVoltage and Ratings\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-start=\"2041\" data-end=\"2075\"\u003e\n\u003cstrong data-start=\"2041\" data-end=\"2059\"\u003eRated Voltage:\u003c\/strong\u003e Up to 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"2078\" data-end=\"2122\"\u003e\n\u003cstrong data-start=\"2078\" data-end=\"2113\"\u003eInterrupting Capacity @ 240VAC:\u003c\/strong\u003e 100 kA\u003c\/li\u003e\n\u003cli data-start=\"2125\" data-end=\"2168\"\u003e\n\u003cstrong data-start=\"2125\" data-end=\"2160\"\u003eInterrupting Capacity @ 480VAC:\u003c\/strong\u003e 65 kA\u003c\/li\u003e\n\u003cli data-start=\"2171\" data-end=\"2214\"\u003e\n\u003cstrong data-start=\"2171\" data-end=\"2206\"\u003eInterrupting Capacity @ 600VAC:\u003c\/strong\u003e 35 kA\u003c\/li\u003e\n\u003cli data-start=\"2217\" data-end=\"2249\"\u003e\n\u003cstrong data-start=\"2217\" data-end=\"2238\"\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"8dxdq5\" data-start=\"2256\" data-end=\"2270\"\u003eProduct Data\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli data-start=\"2273\" data-end=\"2308\"\u003e\n\u003cstrong data-start=\"2273\" data-end=\"2292\"\u003eProduct Series:\u003c\/strong\u003e Eaton M-Frame\u003c\/li\u003e\n\u003cli data-start=\"2311\" data-end=\"2362\"\u003e\n\u003cstrong data-start=\"2311\" data-end=\"2332\"\u003eProduct Category:\u003c\/strong\u003e Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-start=\"2365\" data-end=\"2395\"\u003e\n\u003cstrong data-start=\"2365\" data-end=\"2385\"\u003eConnection Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"2398\" data-end=\"2445\"\u003e\n\u003cstrong data-start=\"2398\" data-end=\"2425\"\u003eTerminal Configuration:\u003c\/strong\u003e Without terminals\u003c\/li\u003e\n\u003cli data-start=\"2448\" data-end=\"2504\"\u003e\n\u003cstrong data-start=\"2448\" data-end=\"2464\"\u003eRating Plug:\u003c\/strong\u003e Not included (required for operation)\u003c\/li\u003e\n\u003cli data-start=\"2507\" data-end=\"2593\"\u003e\n\u003cstrong data-start=\"2507\" data-end=\"2534\"\u003eMounting Compatibility:\u003c\/strong\u003e Designed for compatible Eaton switchgear and panelboards\u003c\/li\u003e\n\u003cli data-start=\"2596\" data-end=\"2701\"\u003e\n\u003cstrong data-start=\"2596\" data-end=\"2623\"\u003eCondition Availability:\u003c\/strong\u003e New, surplus, or professionally refurbished depending on supplier inventory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"gbcsds\" data-start=\"2708\" data-end=\"2726\"\u003eImportant Note\u003c\/h1\u003e\n\u003cp data-start=\"2727\" data-end=\"3275\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThis circuit breaker \u003cstrong data-start=\"2748\" data-end=\"2785\"\u003erequires a rating plug to operate\u003c\/strong\u003e, which is not included with the unit. The rating plug determines the long delay pickup setting and overall operational current rating of the breaker. The unit is also supplied \u003cstrong data-start=\"2962\" data-end=\"2983\"\u003ewithout terminals\u003c\/strong\u003e, allowing configuration flexibility based on installation requirements. Product images typically represent a base model and are provided for identification purposes only. If accessories are purchased with the breaker, they may be installed before shipment to match the desired configuration.\u003c\/p\u003e","brand":"Eaton Cutler Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47488743080185,"sku":"HMDLB3800T35W-CR","price":4999.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47488743112953,"sku":"HMDLB3800T35W-NS","price":7999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HMDLB3800T35W.webp?v=1773016541","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-hmdlb3800t35w-800a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}