{"product_id":"eaton-cutler-hammer-kdb3125-125a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"Eaton Cutler-Hammer KDB3125 125A 3-Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-start=\"143\" data-end=\"902\"\u003eThe \u003cstrong data-start=\"147\" data-end=\"178\"\u003eEaton Cutler-Hammer KDB3125\u003c\/strong\u003e is a reliable \u003cstrong data-start=\"193\" data-end=\"232\"\u003eK-frame molded case circuit breaker\u003c\/strong\u003e engineered to provide dependable protection for \u003cstrong data-start=\"281\" data-end=\"342\"\u003ecommercial and industrial electrical distribution systems\u003c\/strong\u003e. Featuring a \u003cstrong data-start=\"356\" data-end=\"406\"\u003ethermal-magnetic non-interchangeable trip unit\u003c\/strong\u003e, this breaker offers consistent overload and short-circuit protection while maintaining a fixed trip configuration suitable for stable system requirements. Rated at \u003cstrong data-start=\"572\" data-end=\"595\"\u003e125 amperes at 40°C\u003c\/strong\u003e, the KDB3125 delivers strong interrupting capacity for both AC and limited DC applications. Its \u003cstrong data-start=\"692\" data-end=\"726\"\u003ebolt-on mounting configuration\u003c\/strong\u003e ensures secure installation in panelboards and switchboards, while \u003cstrong data-start=\"794\" data-end=\"839\"\u003estandard aluminum line and load terminals\u003c\/strong\u003e simplify wiring and provide dependable electrical connections.\u003c\/p\u003e\n\u003ch2 data-section-id=\"3ipjz4\" data-start=\"909\" data-end=\"934\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"937\" data-end=\"967\"\u003eBrand: Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"970\" data-end=\"986\"\u003eModel: KDB3125\u003c\/li\u003e\n\u003cli data-start=\"989\" data-end=\"1039\"\u003eBreaker Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-start=\"1042\" data-end=\"1070\"\u003eFrame Style: KDB (K-Frame)\u003c\/li\u003e\n\u003cli data-start=\"1073\" data-end=\"1100\"\u003eRated Current: 125 Ampere\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1128\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-start=\"1131\" data-end=\"1199\"\u003eTrip Unit Type: \u003cstrong data-start=\"1147\" data-end=\"1197\"\u003eThermal Magnetic Non-Interchangeable Trip Unit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1202\" data-end=\"1237\"\u003eMounting Type: Bolt-On Connection\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1306\"\u003eStandard Lug Type: Aluminum Line and Load End Terminals Standard\u003c\/li\u003e\n\u003cli data-start=\"1309\" data-end=\"1351\"\u003eWarranty: One Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1358\" data-end=\"1385\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1388\" data-end=\"1409\"\u003eFrame Type: K-Frame\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1495\"\u003eTrip Adjustment Range: \u003cstrong data-start=\"1435\" data-end=\"1493\"\u003eAdjustable from 5× to 10× the continuous ampere rating\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1498\" data-end=\"1541\"\u003eOperating Temperature Reference: \u003cstrong data-start=\"1531\" data-end=\"1539\"\u003e40°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1600\"\u003eProtection Type: Overload and Short Circuit Protection\u003c\/li\u003e\n\u003cli data-start=\"1603\" data-end=\"1685\"\u003eBreaker Construction: Molded insulated case for durability and electrical safety\u003c\/li\u003e\n\u003cli data-start=\"1688\" data-end=\"1763\"\u003eApplication Type: Commercial and industrial power distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"ihrae0\" data-start=\"1770\" data-end=\"1792\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1795\" data-end=\"1825\"\u003eMaximum Voltage: \u003cstrong data-start=\"1812\" data-end=\"1823\"\u003e600 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1828\" data-end=\"1870\"\u003eInterrupting Rating: \u003cstrong data-start=\"1849\" data-end=\"1868\"\u003e65 kA @ 240 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1873\" data-end=\"1915\"\u003eInterrupting Rating: \u003cstrong data-start=\"1894\" data-end=\"1913\"\u003e35 kA @ 480 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1918\" data-end=\"1960\"\u003eInterrupting Rating: \u003cstrong data-start=\"1939\" data-end=\"1958\"\u003e25 kA @ 600 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1963\" data-end=\"2008\"\u003eDC Interrupting Rating: \u003cstrong data-start=\"1987\" data-end=\"2006\"\u003e10 kA @ 250 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2011\" data-end=\"2034\"\u003eFrequency: \u003cstrong data-start=\"2022\" data-end=\"2034\"\u003e50\/60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"we2dfi\" data-start=\"2041\" data-end=\"2056\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2059\" data-end=\"2096\"\u003eManufacturer: Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"2099\" data-end=\"2127\"\u003eProduct Series: KDB Series\u003c\/li\u003e\n\u003cli data-start=\"2130\" data-end=\"2153\"\u003eModel Number: KDB3125\u003c\/li\u003e\n\u003cli data-start=\"2156\" data-end=\"2178\"\u003eCurrent Rating: 125A\u003c\/li\u003e\n\u003cli data-start=\"2181\" data-end=\"2201\"\u003eNumber of Poles: 3\u003c\/li\u003e\n\u003cli data-start=\"2204\" data-end=\"2230\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"2233\" data-end=\"2295\"\u003eTerminal Type: Aluminum Line and Load End Terminals Included\u003c\/li\u003e\n\u003cli data-start=\"2298\" data-end=\"2386\"\u003eApplication: Electrical panelboards, switchboards, and industrial distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2393\" data-end=\"2412\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2413\" data-end=\"2886\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image typically represents a \u003cstrong data-start=\"2454\" data-end=\"2501\"\u003ebase model for identification purposes only\u003c\/strong\u003e, and the final configuration may vary depending on installed accessories or options. If accessories are ordered together with the breaker, they can be \u003cstrong data-start=\"2653\" data-end=\"2742\"\u003einstalled according to your specific configuration requirements at no additional cost\u003c\/strong\u003e. Please include the necessary configuration details in the \u003cstrong data-start=\"2802\" data-end=\"2843\"\u003eorder comment section during checkout\u003c\/strong\u003e to ensure proper assembly before shipment.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47514527826169,"sku":"KDB3125-CR","price":1899.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47514527858937,"sku":"KDB3125-NS","price":2499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/KDB3125.webp?v=1773448145","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-kdb3125-125a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}