{"product_id":"eaton-cutler-hammer-kg3350wa12s43z04-350a-3-pole-generator-molded-case-circuit-breaker-bolt-on-600vac-with-a12-auxiliary-s43-shunt-trip","title":"Eaton Cutler-Hammer KG3350WA12S43Z04 350A 3-Pole Generator Molded Case Circuit Breaker – Bolt-On – 600VAC with A12 Auxiliary \u0026 S43 Shunt Trip","description":"\u003cp data-start=\"192\" data-end=\"566\"\u003eThe \u003cstrong data-start=\"196\" data-end=\"236\"\u003eEaton Cutler-Hammer KG3350WA12S43Z04\u003c\/strong\u003e is a \u003cstrong data-start=\"242\" data-end=\"291\"\u003eK-frame molded case generator circuit breaker\u003c\/strong\u003e engineered for industrial and generator applications. It features a \u003cstrong data-start=\"360\" data-end=\"406\"\u003ethermal-magnetic interchangeable trip unit\u003c\/strong\u003e with a \u003cstrong data-start=\"414\" data-end=\"450\"\u003e500–1000 Amp magnetic trip range\u003c\/strong\u003e for precise overload and short-circuit protection. This model comes equipped with \u003cstrong data-start=\"533\" data-end=\"563\"\u003edual configuration options\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"570\" data-end=\"663\"\u003e\n\u003cstrong data-start=\"570\" data-end=\"594\"\u003eA12 Auxiliary Switch\u003c\/strong\u003e – 2-A (Open) \/ 2-B (Closed), Right Pole Mounted, Exiting Same Side\u003c\/li\u003e\n\u003cli data-start=\"666\" data-end=\"744\"\u003e\n\u003cstrong data-start=\"666\" data-end=\"684\"\u003eS43 Shunt Trip\u003c\/strong\u003e – 12–24 VAC\/VDC, Left Pole Mounted, Exiting Opposite Side\u003c\/li\u003e\n\u003cli\u003eRated at \u003cstrong data-start=\"755\" data-end=\"777\"\u003e350 Ampere at 40°C\u003c\/strong\u003e, the breaker provides robust protection and flexible integration for generator panels and switchgear systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"894\" data-end=\"909\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"912\" data-end=\"989\"\u003e\n\u003cstrong data-start=\"912\" data-end=\"949\"\u003eK-Frame Generator Circuit Breaker\u003c\/strong\u003e for high-reliability power protection\u003c\/li\u003e\n\u003cli data-start=\"992\" data-end=\"1040\"\u003e\u003cstrong data-start=\"992\" data-end=\"1038\"\u003eThermal-Magnetic Interchangeable Trip Unit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1043\" data-end=\"1072\"\u003e\n\u003cstrong data-start=\"1043\" data-end=\"1069\"\u003eDual Options Installed\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1077\" data-end=\"1123\"\u003eA12 Auxiliary Switch (Right Pole, Same Side)\u003c\/li\u003e\n\u003cli data-start=\"1128\" data-end=\"1171\"\u003eS43 Shunt Trip (Left Pole, Opposite Side)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1174\" data-end=\"1220\"\u003e\n\u003cstrong data-start=\"1174\" data-end=\"1196\"\u003eBolt-On Connection\u003c\/strong\u003e for easy installation\u003c\/li\u003e\n\u003cli data-start=\"1223\" data-end=\"1261\"\u003e\u003cstrong data-start=\"1223\" data-end=\"1259\"\u003eLine and Load Terminals Standard\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"1268\" data-end=\"1285\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1288\" data-end=\"1325\"\u003eManufacturer: Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"1328\" data-end=\"1353\"\u003eModel: KG3350WA12S43Z04\u003c\/li\u003e\n\u003cli data-start=\"1356\" data-end=\"1371\"\u003eFrame Type: K\u003c\/li\u003e\n\u003cli data-start=\"1374\" data-end=\"1401\"\u003eRated Current: 350 Ampere\u003c\/li\u003e\n\u003cli data-start=\"1404\" data-end=\"1414\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-start=\"1417\" data-end=\"1443\"\u003eMaximum Voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"1446\" data-end=\"1467\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1470\" data-end=\"1520\"\u003eTrip Unit Type: Thermal-Magnetic Interchangeable\u003c\/li\u003e\n\u003cli data-start=\"1523\" data-end=\"1561\"\u003eMagnetic Trip Range: 500–1000 Ampere\u003c\/li\u003e\n\u003cli data-start=\"1564\" data-end=\"1588\"\u003eInterrupting Capacity:\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1593\" data-end=\"1610\"\u003e18 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"1615\" data-end=\"1632\"\u003e14 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"1637\" data-end=\"1654\"\u003e10 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1657\" data-end=\"1678\"\u003eConnection: Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1681\" data-end=\"1729\"\u003eStandard Lug Type: Line and Load End Terminals\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1752\"\u003eWarranty: One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"1759\" data-end=\"1774\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1777\" data-end=\"1822\"\u003eIndustrial generator protection and control\u003c\/li\u003e\n\u003cli data-start=\"1825\" data-end=\"1894\"\u003eRemote tripping and monitoring via auxiliary and shunt trip options\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1941\"\u003eSwitchgear and generator panel integration\u003c\/li\u003e\n\u003cli data-start=\"1944\" data-end=\"1986\"\u003eMedium-to-large generator backup systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"xe9fpi\" data-start=\"1993\" data-end=\"2001\"\u003eNotes\u003c\/h2\u003e\n\u003cp data-start=\"2002\" data-end=\"2236\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image represents a \u003cstrong data-start=\"2033\" data-end=\"2047\"\u003ebase model\u003c\/strong\u003e for identification. Eaton offers \u003cstrong data-start=\"2081\" data-end=\"2148\"\u003einstallation of your selected accessories at no additional cost\u003c\/strong\u003e—simply provide configuration instructions in the \u003cstrong data-start=\"2198\" data-end=\"2219\"\u003eorder comment box\u003c\/strong\u003e during checkout.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47515740995833,"sku":"KG3350WA12S43Z04-CR","price":3199.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47515741028601,"sku":"KG3350WA12S43Z04-NS","price":4499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/KG3350WA12S43Z04.webp?v=1773478299","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-kg3350wa12s43z04-350a-3-pole-generator-molded-case-circuit-breaker-bolt-on-600vac-with-a12-auxiliary-s43-shunt-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}