{"product_id":"eaton-cutler-hammer-kg3400s46-400a-3-pole-generator-molded-case-circuit-breaker-bolt-on-600vac-thermal-magnetic-interchangeable-trip-1000-2000a-with-s46-shunt-trip-option","title":"Eaton Cutler-Hammer KG3400S46 400A 3-Pole Generator Molded Case Circuit Breaker – Bolt-On – 600VAC – Thermal-Magnetic Interchangeable Trip (1000–2000A) with S46 Shunt Trip Option","description":"\u003cp data-start=\"229\" data-end=\"573\"\u003eThe \u003cstrong data-start=\"233\" data-end=\"252\"\u003eEaton KG3400S46\u003c\/strong\u003e is a \u003cstrong data-start=\"258\" data-end=\"307\"\u003eK-frame molded case generator circuit breaker\u003c\/strong\u003e engineered for \u003cstrong data-start=\"323\" data-end=\"370\"\u003eindustrial and generator protection systems\u003c\/strong\u003e. It utilizes a \u003cstrong data-start=\"386\" data-end=\"432\"\u003ethermal-magnetic interchangeable trip unit\u003c\/strong\u003e with a \u003cstrong data-start=\"440\" data-end=\"477\"\u003e1000–2000 Amp magnetic trip range\u003c\/strong\u003e, delivering dependable overload and short-circuit protection for generator-based power systems.\u003c\/p\u003e\n\u003cp data-start=\"575\" data-end=\"802\"\u003eThis configuration includes the \u003cstrong data-start=\"607\" data-end=\"621\"\u003eS46 option\u003c\/strong\u003e, which adds a \u003cstrong data-start=\"636\" data-end=\"660\"\u003e12–24V DC shunt trip\u003c\/strong\u003e mounted on the \u003cstrong data-start=\"676\" data-end=\"690\"\u003eright pole\u003c\/strong\u003e with \u003cstrong data-start=\"696\" data-end=\"716\"\u003erear exit wiring\u003c\/strong\u003e, enabling \u003cstrong data-start=\"727\" data-end=\"757\"\u003eremote tripping capability\u003c\/strong\u003e for enhanced operational control and safety.\u003c\/p\u003e\n\u003cp data-start=\"804\" data-end=\"968\"\u003eRated for \u003cstrong data-start=\"814\" data-end=\"837\"\u003e400 Amperes at 40°C\u003c\/strong\u003e with \u003cstrong data-start=\"843\" data-end=\"854\"\u003e3 poles\u003c\/strong\u003e, this breaker is suitable for \u003cstrong data-start=\"885\" data-end=\"967\"\u003egenerator panels, switchgear assemblies, and backup power distribution systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"975\" data-end=\"990\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"993\" data-end=\"1079\"\u003e\n\u003cstrong data-start=\"993\" data-end=\"1030\"\u003eK-Frame Generator Circuit Breaker\u003c\/strong\u003e designed for generator protection applications\u003c\/li\u003e\n\u003cli data-start=\"1082\" data-end=\"1162\"\u003e\n\u003cstrong data-start=\"1082\" data-end=\"1128\"\u003eThermal-Magnetic Interchangeable Trip Unit\u003c\/strong\u003e for reliable circuit protection\u003c\/li\u003e\n\u003cli data-start=\"1165\" data-end=\"1205\"\u003e\n\u003cstrong data-start=\"1165\" data-end=\"1189\"\u003eMagnetic trip range:\u003c\/strong\u003e 1000–2000 Amp\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1280\"\u003e\n\u003cstrong data-start=\"1208\" data-end=\"1234\"\u003eS46 Shunt Trip Option:\u003c\/strong\u003e 12–24V DC, Right Pole Mounted, Exiting Rear\u003c\/li\u003e\n\u003cli data-start=\"1283\" data-end=\"1331\"\u003e\n\u003cstrong data-start=\"1283\" data-end=\"1305\"\u003eBolt-On Connection\u003c\/strong\u003e for secure installation\u003c\/li\u003e\n\u003cli data-start=\"1334\" data-end=\"1374\"\u003e\u003cstrong data-start=\"1334\" data-end=\"1374\"\u003eLine and Load End Terminals Standard\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"1381\" data-end=\"1398\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1401\" data-end=\"1442\"\u003e\n\u003cstrong data-start=\"1401\" data-end=\"1418\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"1445\" data-end=\"1467\"\u003e\n\u003cstrong data-start=\"1445\" data-end=\"1455\"\u003eModel:\u003c\/strong\u003e KG3400S46\u003c\/li\u003e\n\u003cli data-start=\"1470\" data-end=\"1489\"\u003e\n\u003cstrong data-start=\"1470\" data-end=\"1485\"\u003eFrame Type:\u003c\/strong\u003e K\u003c\/li\u003e\n\u003cli data-start=\"1492\" data-end=\"1523\"\u003e\n\u003cstrong data-start=\"1492\" data-end=\"1510\"\u003eRated Current:\u003c\/strong\u003e 400 Ampere\u003c\/li\u003e\n\u003cli data-start=\"1526\" data-end=\"1540\"\u003e\n\u003cstrong data-start=\"1526\" data-end=\"1536\"\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-start=\"1543\" data-end=\"1573\"\u003e\n\u003cstrong data-start=\"1543\" data-end=\"1563\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"1576\" data-end=\"1601\"\u003e\n\u003cstrong data-start=\"1576\" data-end=\"1590\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1604\" data-end=\"1658\"\u003e\n\u003cstrong data-start=\"1604\" data-end=\"1623\"\u003eTrip Unit Type:\u003c\/strong\u003e Thermal-Magnetic Interchangeable\u003c\/li\u003e\n\u003cli data-start=\"1661\" data-end=\"1701\"\u003e\n\u003cstrong data-start=\"1661\" data-end=\"1685\"\u003eMagnetic Trip Range:\u003c\/strong\u003e 1000–2000 Amp\u003c\/li\u003e\n\u003cli data-start=\"1704\" data-end=\"1732\"\u003e\u003cstrong data-start=\"1704\" data-end=\"1730\"\u003eInterrupting Capacity:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1737\" data-end=\"1754\"\u003e18 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"1759\" data-end=\"1776\"\u003e14 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"1781\" data-end=\"1798\"\u003e10 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1801\" data-end=\"1826\"\u003e\n\u003cstrong data-start=\"1801\" data-end=\"1816\"\u003eConnection:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1829\" data-end=\"1881\"\u003e\n\u003cstrong data-start=\"1829\" data-end=\"1851\"\u003eStandard Lug Type:\u003c\/strong\u003e Line and Load End Terminals\u003c\/li\u003e\n\u003cli data-start=\"1884\" data-end=\"1911\"\u003e\n\u003cstrong data-start=\"1884\" data-end=\"1909\"\u003eConfiguration Option:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli data-start=\"1916\" data-end=\"1981\"\u003e\n\u003cstrong data-start=\"1916\" data-end=\"1924\"\u003eS46:\u003c\/strong\u003e 12–24V DC Shunt Trip, Right Pole Mounted, Exiting Rear\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1984\" data-end=\"2006\"\u003e\n\u003cstrong data-start=\"1984\" data-end=\"1997\"\u003eWarranty:\u003c\/strong\u003e One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"2013\" data-end=\"2028\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2031\" data-end=\"2061\"\u003eGenerator protection systems\u003c\/li\u003e\n\u003cli data-start=\"2064\" data-end=\"2101\"\u003eIndustrial switchgear installations\u003c\/li\u003e\n\u003cli data-start=\"2104\" data-end=\"2140\"\u003eBackup and emergency power systems\u003c\/li\u003e\n\u003cli data-start=\"2143\" data-end=\"2186\"\u003eMedium-capacity power distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"xe9fpi\" data-start=\"2193\" data-end=\"2201\"\u003eNotes\u003c\/h2\u003e\n\u003cp data-start=\"2202\" data-end=\"2479\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image represents a \u003cstrong data-start=\"2233\" data-end=\"2280\"\u003ebase model for identification purposes only\u003c\/strong\u003e. If accessories are purchased with the breaker, \u003cstrong data-start=\"2329\" data-end=\"2376\"\u003ethey can be installed at no additional cost\u003c\/strong\u003e. Provide configuration details in the \u003cstrong data-start=\"2415\" data-end=\"2452\"\u003eorder comment box during checkout\u003c\/strong\u003e to ensure proper assembly.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47516740616441,"sku":"KG3400S46-CR","price":2899.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47516740649209,"sku":"KG3400S46-NS","price":4199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/KG3400S46.webp?v=1773493502","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-kg3400s46-400a-3-pole-generator-molded-case-circuit-breaker-bolt-on-600vac-thermal-magnetic-interchangeable-trip-1000-2000a-with-s46-shunt-trip-option","provider":"My Circuit Breakers","version":"1.0","type":"link"}