{"product_id":"eaton-cutler-hammer-kg3400w-400a-3-pole-generator-molded-case-circuit-breaker-bolt-on-600vac-thermal-magnetic-interchangeable-trip","title":"Eaton Cutler-Hammer KG3400W 400A 3-Pole Generator Molded Case Circuit Breaker – Bolt-On – 600VAC – Thermal-Magnetic Interchangeable Trip","description":"\u003cp data-start=\"220\" data-end=\"588\"\u003eThe \u003cstrong data-start=\"224\" data-end=\"241\"\u003eEaton KG3400W\u003c\/strong\u003e is a \u003cstrong data-start=\"247\" data-end=\"296\"\u003eK-frame molded case generator circuit breaker\u003c\/strong\u003e engineered for \u003cstrong data-start=\"312\" data-end=\"378\"\u003egenerator protection and industrial power distribution systems\u003c\/strong\u003e. It incorporates a \u003cstrong data-start=\"398\" data-end=\"444\"\u003ethermal-magnetic interchangeable trip unit\u003c\/strong\u003e with a \u003cstrong data-start=\"452\" data-end=\"489\"\u003e1000–2000 Amp magnetic trip range\u003c\/strong\u003e, delivering dependable overload and short-circuit protection for demanding generator applications.\u003c\/p\u003e\n\u003cp data-start=\"590\" data-end=\"919\"\u003eRated at \u003cstrong data-start=\"599\" data-end=\"622\"\u003e400 Amperes at 40°C\u003c\/strong\u003e with \u003cstrong data-start=\"628\" data-end=\"639\"\u003e3 poles\u003c\/strong\u003e, this breaker supports \u003cstrong data-start=\"663\" data-end=\"693\"\u003e600VAC systems at 50\/60 Hz\u003c\/strong\u003e. The \u003cstrong data-start=\"699\" data-end=\"720\"\u003e“W” configuration\u003c\/strong\u003e indicates the unit is supplied \u003cstrong data-start=\"752\" data-end=\"782\"\u003ewithout standard terminals\u003c\/strong\u003e, allowing installers to configure the breaker with \u003cstrong data-start=\"834\" data-end=\"879\"\u003ecustom lug kits or connection accessories\u003c\/strong\u003e based on the installation requirements.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"926\" data-end=\"941\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"944\" data-end=\"995\"\u003e\u003cstrong data-start=\"944\" data-end=\"993\"\u003eK-Frame Generator Molded Case Circuit Breaker\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"998\" data-end=\"1046\"\u003e\u003cstrong data-start=\"998\" data-end=\"1044\"\u003eThermal-Magnetic Interchangeable Trip Unit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1049\" data-end=\"1089\"\u003e\n\u003cstrong data-start=\"1049\" data-end=\"1073\"\u003eMagnetic trip range:\u003c\/strong\u003e 1000–2000 Amp\u003c\/li\u003e\n\u003cli data-start=\"1092\" data-end=\"1136\"\u003e\n\u003cstrong data-start=\"1092\" data-end=\"1114\"\u003eBolt-On Connection\u003c\/strong\u003e for secure mounting\u003c\/li\u003e\n\u003cli data-start=\"1139\" data-end=\"1222\"\u003e\n\u003cstrong data-start=\"1139\" data-end=\"1178\"\u003eWithout Terminals (W Configuration)\u003c\/strong\u003e for flexible lug or terminal installation\u003c\/li\u003e\n\u003cli data-start=\"1225\" data-end=\"1285\"\u003e\u003cstrong data-start=\"1225\" data-end=\"1285\"\u003eDesigned for generator and industrial protection systems\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"1292\" data-end=\"1309\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1312\" data-end=\"1353\"\u003e\n\u003cstrong data-start=\"1312\" data-end=\"1329\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"1356\" data-end=\"1376\"\u003e\n\u003cstrong data-start=\"1356\" data-end=\"1366\"\u003eModel:\u003c\/strong\u003e KG3400W\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1398\"\u003e\n\u003cstrong data-start=\"1379\" data-end=\"1394\"\u003eFrame Type:\u003c\/strong\u003e K\u003c\/li\u003e\n\u003cli data-start=\"1401\" data-end=\"1432\"\u003e\n\u003cstrong data-start=\"1401\" data-end=\"1419\"\u003eRated Current:\u003c\/strong\u003e 400 Ampere\u003c\/li\u003e\n\u003cli data-start=\"1435\" data-end=\"1449\"\u003e\n\u003cstrong data-start=\"1435\" data-end=\"1445\"\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1482\"\u003e\n\u003cstrong data-start=\"1452\" data-end=\"1472\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"1485\" data-end=\"1510\"\u003e\n\u003cstrong data-start=\"1485\" data-end=\"1499\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1567\"\u003e\n\u003cstrong data-start=\"1513\" data-end=\"1532\"\u003eTrip Unit Type:\u003c\/strong\u003e Thermal-Magnetic Interchangeable\u003c\/li\u003e\n\u003cli data-start=\"1570\" data-end=\"1610\"\u003e\n\u003cstrong data-start=\"1570\" data-end=\"1594\"\u003eMagnetic Trip Range:\u003c\/strong\u003e 1000–2000 Amp\u003c\/li\u003e\n\u003cli data-start=\"1613\" data-end=\"1641\"\u003e\u003cstrong data-start=\"1613\" data-end=\"1639\"\u003eInterrupting Capacity:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1646\" data-end=\"1663\"\u003e18 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"1668\" data-end=\"1685\"\u003e14 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"1690\" data-end=\"1707\"\u003e10 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1735\"\u003e\n\u003cstrong data-start=\"1710\" data-end=\"1725\"\u003eConnection:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1738\" data-end=\"1780\"\u003e\n\u003cstrong data-start=\"1738\" data-end=\"1760\"\u003eStandard Lug Type:\u003c\/strong\u003e Without Terminals\u003c\/li\u003e\n\u003cli data-start=\"1783\" data-end=\"1805\"\u003e\n\u003cstrong data-start=\"1783\" data-end=\"1796\"\u003eWarranty:\u003c\/strong\u003e One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"1812\" data-end=\"1827\"\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1830\" data-end=\"1860\"\u003eGenerator protection systems\u003c\/li\u003e\n\u003cli data-start=\"1863\" data-end=\"1897\"\u003eIndustrial switchgear assemblies\u003c\/li\u003e\n\u003cli data-start=\"1900\" data-end=\"1934\"\u003eCustom power distribution panels\u003c\/li\u003e\n\u003cli data-start=\"1937\" data-end=\"1977\"\u003eBackup and emergency power installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"xe9fpi\" data-start=\"1984\" data-end=\"1992\"\u003eNotes\u003c\/h2\u003e\n\u003cp data-start=\"1993\" data-end=\"2285\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image represents a \u003cstrong data-start=\"2024\" data-end=\"2071\"\u003ebase model for identification purposes only\u003c\/strong\u003e. If accessories or terminal kits are ordered with the breaker, \u003cstrong data-start=\"2135\" data-end=\"2182\"\u003ethey can be installed at no additional cost\u003c\/strong\u003e. Provide configuration details in the \u003cstrong data-start=\"2221\" data-end=\"2258\"\u003eorder comment box during checkout\u003c\/strong\u003e to ensure proper assembly.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47516761456889,"sku":"KG3400W-CR","price":2499.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47516761489657,"sku":"KG3400W-NS","price":3799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/KG3400W.webp?v=1773494252","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-kg3400w-400a-3-pole-generator-molded-case-circuit-breaker-bolt-on-600vac-thermal-magnetic-interchangeable-trip","provider":"My Circuit Breakers","version":"1.0","type":"link"}