{"product_id":"eaton-cutler-hammer-mining-e2n312w-1200a-3p-mining-mccb-bolt-on-600vac","title":"Eaton Cutler Hammer Mining E2N312W 1200A 3P Mining MCCB – Bolt On – 600VAC","description":"\u003cp data-start=\"110\" data-end=\"576\"\u003eThe Eaton E2N312W is a rugged molded case mining circuit breaker (MCCB) designed for industrial and mining applications requiring both thermal and magnetic protection. Built on the E2N frame, this breaker provides reliable thermal-magnetic trip protection, combining overload (thermal) and short-circuit (magnetic) protection in a single compact unit. It is suitable for heavy-duty 3-pole 600VAC systems, delivering dependable operation under demanding conditions.\u003c\/p\u003e\n\u003ch2 data-section-id=\"193hxb4\" data-start=\"583\" data-end=\"612\"\u003e\u003cstrong data-start=\"586\" data-end=\"612\"\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"615\" data-end=\"645\"\u003eBrand: Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-start=\"648\" data-end=\"664\"\u003eModel: E2N312W\u003c\/li\u003e\n\u003cli data-start=\"667\" data-end=\"689\"\u003eRated Current: 1200A\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"712\"\u003eNumber of Poles: 3\u003c\/li\u003e\n\u003cli data-start=\"715\" data-end=\"772\"\u003eBreaker Type: Molded Case Mining Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-start=\"775\" data-end=\"826\"\u003eTrip Unit: Thermal-Magnetic (Non-Interchangeable)\u003c\/li\u003e\n\u003cli data-start=\"829\" data-end=\"853\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"856\" data-end=\"877\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"880\" data-end=\"895\"\u003eFrame Type: N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"902\" data-end=\"933\"\u003e\u003cstrong data-start=\"905\" data-end=\"933\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"936\" data-end=\"961\"\u003eTrip Setting: 1250–5000\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1035\"\u003eTrip Function: Thermal-Magnetic (Overload + Short-Circuit Protection)\u003c\/li\u003e\n\u003cli data-start=\"1038\" data-end=\"1064\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1067\" data-end=\"1127\"\u003eDesigned for heavy-duty mining and industrial environments\u003c\/li\u003e\n\u003cli data-start=\"1130\" data-end=\"1179\"\u003eStandard Lug Type: Without terminals (standard)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"hpn9aw\" data-start=\"1186\" data-end=\"1212\"\u003e\u003cstrong data-start=\"1189\" data-end=\"1212\"\u003eVoltage and Ratings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1215\" data-end=\"1250\"\u003eRated Operational Voltage: 600VAC\u003c\/li\u003e\n\u003cli data-start=\"1253\" data-end=\"1277\"\u003eInterrupting Capacity:\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1282\" data-end=\"1298\"\u003e65 kA @ 240VAC\u003c\/li\u003e\n\u003cli data-start=\"1303\" data-end=\"1319\"\u003e50 kA @ 480VAC\u003c\/li\u003e\n\u003cli data-start=\"1324\" data-end=\"1340\"\u003e25 kA @ 600VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"n53vge\" data-start=\"1347\" data-end=\"1366\"\u003e\u003cstrong data-start=\"1350\" data-end=\"1366\"\u003eProduct Data\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1369\" data-end=\"1424\"\u003eApplication: Mining and industrial power distribution\u003c\/li\u003e\n\u003cli data-start=\"1427\" data-end=\"1445\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1497\"\u003eInstallation: Panel-mounted, bolt-on connection\u003c\/li\u003e\n\u003cli data-start=\"1500\" data-end=\"1565\"\u003eConfiguration: Base model (accessories can be added on request)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1pjndkj\" data-start=\"1572\" data-end=\"1595\"\u003e\u003cstrong data-start=\"1575\" data-end=\"1593\"\u003eImportant Note\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1596\" data-end=\"1974\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThis breaker combines thermal and magnetic protection. Product images are for identification purposes only. Accessories ordered with the breaker can be installed prior to shipment at no additional cost—please provide configuration details during checkout. Installation must be performed by qualified personnel in accordance with applicable electrical codes and safety standards.\u003c\/p\u003e","brand":"Eaton Cutler Hammer Mining","offers":[{"title":"Certified Reconditioned","offer_id":47562366681337,"sku":"E2N312W","price":9999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/E2N312W.webp?v=1774438636","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-mining-e2n312w-1200a-3p-mining-mccb-bolt-on-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}