{"product_id":"eaton-cutler-hammer-mining-e2nm3600w-600a-3p-molded-case-mining-circuit-breaker-bolt-on-1000vac","title":"Eaton Cutler Hammer Mining E2NM3600W 600A 3P Molded Case Mining Circuit Breaker – Bolt-On – 1000VAC","description":"\u003cp data-start=\"208\" data-end=\"629\"\u003eThe Eaton E2NM3600W is a heavy-duty molded case mining circuit breaker designed for high-demand industrial and mining applications. It features a non-interchangeable thermal-magnetic trip unit, ensuring reliable circuit protection at 600 amperes at 40°C. This 3-pole breaker is engineered for high-voltage systems up to 1000VAC, delivering consistent performance, durability, and safety in harsh operating environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"xddb3k\" data-start=\"636\" data-end=\"667\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"640\" data-end=\"665\"\u003eProduct Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"668\" data-end=\"886\"\u003e\n\u003cli data-section-id=\"1f0p3sc\" data-start=\"668\" data-end=\"689\"\u003eFrame Style: E2NM\u003c\/li\u003e\n\u003cli data-section-id=\"1uagnpo\" data-start=\"690\" data-end=\"742\"\u003eBreaker Type: Molded Case Mining Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"743\" data-end=\"755\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"193xwen\" data-start=\"756\" data-end=\"782\"\u003eAmperage: 600A at 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"4kab9a\" data-start=\"783\" data-end=\"806\"\u003eMount Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"nx5s05\" data-start=\"807\" data-end=\"835\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"megwq\" data-start=\"836\" data-end=\"886\"\u003eStandard Lug Type: Specified per configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j6c2zs\" data-start=\"893\" data-end=\"926\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"897\" data-end=\"924\"\u003eTechnical Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"927\" data-end=\"1212\"\u003e\n\u003cli data-section-id=\"1tf21cz\" data-start=\"927\" data-end=\"977\"\u003eNon-interchangeable thermal-magnetic trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"1bsshru\" data-start=\"978\" data-end=\"1004\"\u003eTrip Setting: 500–2500\u003c\/li\u003e\n\u003cli data-section-id=\"pebra5\" data-start=\"1005\" data-end=\"1067\"\u003eDesigned for mining and heavy-duty industrial applications\u003c\/li\u003e\n\u003cli data-section-id=\"15hagsk\" data-start=\"1068\" data-end=\"1122\"\u003eHigh durability under extreme operating conditions\u003c\/li\u003e\n\u003cli data-section-id=\"o1lul2\" data-start=\"1123\" data-end=\"1212\"\u003eInterrupting Ratings:\n\u003cul data-start=\"1151\" data-end=\"1212\"\u003e\n\u003cli data-section-id=\"12ml8q7\" data-start=\"1151\" data-end=\"1169\"\u003e50 kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1pw4clj\" data-start=\"1172\" data-end=\"1190\"\u003e25 kA @ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"c1o5u8\" data-start=\"1193\" data-end=\"1212\"\u003e25 kA @ 1000VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1p7hm8r\" data-start=\"1219\" data-end=\"1248\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1223\" data-end=\"1246\"\u003eVoltage and Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1249\" data-end=\"1402\"\u003e\n\u003cli data-section-id=\"zhg7gz\" data-start=\"1249\" data-end=\"1287\"\u003eMaximum Voltage: 1000VAC @ 50\/60Hz\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"1288\" data-end=\"1300\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"193xwen\" data-start=\"1301\" data-end=\"1327\"\u003eAmperage: 600A at 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"bbqtt\" data-start=\"1328\" data-end=\"1402\"\u003eInterrupting Capacity: 50 kA @ 480VAC, 25 kA @ 600VAC, 25 kA @ 1000VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"4gmzrx\" data-start=\"1409\" data-end=\"1431\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1429\"\u003eProduct Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1432\" data-end=\"1536\"\u003e\n\u003cli data-section-id=\"1p41d7g\" data-start=\"1432\" data-end=\"1471\"\u003eManufacturer: Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-section-id=\"1am5t8t\" data-start=\"1472\" data-end=\"1494\"\u003eWarranty: One Year\u003c\/li\u003e\n\u003cli data-section-id=\"1rv463h\" data-start=\"1495\" data-end=\"1518\"\u003eConnection: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"hxa3h5\" data-start=\"1519\" data-end=\"1536\"\u003eFrame Type: N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1vyqyhc\" data-start=\"1543\" data-end=\"1567\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1565\"\u003eImportant Note\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1568\" data-end=\"1909\"\u003eThe product image represents a base model for identification purposes only. If ordering accessories along with the breaker, Eaton will install them to meet your specific configuration needs at no additional cost. Please provide all necessary information in the order comment box during checkout to ensure proper assembly and functionality.\u003c\/p\u003e","brand":"Eaton Cutler Hammer Mining","offers":[{"title":"Certified Reconditioned","offer_id":47745983054073,"sku":"E2NM3600W","price":8999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/E2NM3600W.webp?v=1774985355","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-mining-e2nm3600w-600a-3p-molded-case-mining-circuit-breaker-bolt-on-1000vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}