{"product_id":"eaton-cutler-hammer-nd312t36w-1200a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"Eaton Cutler Hammer ND312T36W 1200A 3-Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-start=\"145\" data-end=\"509\"\u003eThe \u003cstrong data-start=\"149\" data-end=\"162\"\u003eND312T36W\u003c\/strong\u003e is a \u003cstrong data-start=\"168\" data-end=\"219\"\u003e1200 Ampere, 3-pole molded case circuit breaker\u003c\/strong\u003e with an \u003cstrong data-start=\"228\" data-end=\"320\"\u003eLSIG (Long, Short, Instantaneous, Ground Fault) electronic non-interchangeable trip unit\u003c\/strong\u003e (Digitrip RMS 310). It provides robust protection against overloads, short circuits, instantaneous faults, and ground faults, making it ideal for industrial and commercial power systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"516\" data-end=\"532\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"535\" data-end=\"600\"\u003e\n\u003cstrong data-start=\"535\" data-end=\"579\"\u003eElectronic Non-Interchangeable Trip Unit\u003c\/strong\u003e – Digitrip RMS 310\u003c\/li\u003e\n\u003cli data-start=\"603\" data-end=\"629\"\u003e\u003cstrong data-start=\"603\" data-end=\"627\"\u003eLSIG Trip Functions:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"634\" data-end=\"687\"\u003e\n\u003cstrong data-start=\"634\" data-end=\"640\"\u003eL:\u003c\/strong\u003e Adjustable Long Delay Pickup via rating plug\u003c\/li\u003e\n\u003cli data-start=\"692\" data-end=\"757\"\u003e\n\u003cstrong data-start=\"692\" data-end=\"698\"\u003eS:\u003c\/strong\u003e Adjustable Short Delay with fixed (l2t) or flat response\u003c\/li\u003e\n\u003cli data-start=\"762\" data-end=\"802\"\u003e\n\u003cstrong data-start=\"762\" data-end=\"768\"\u003eI:\u003c\/strong\u003e Adjustable Instantaneous Pickup\u003c\/li\u003e\n\u003cli data-start=\"807\" data-end=\"884\"\u003e\n\u003cstrong data-start=\"807\" data-end=\"813\"\u003eG:\u003c\/strong\u003e Adjustable Ground Fault Pickup with adjustable delay (flat response)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"887\" data-end=\"938\"\u003eHigh interrupting ratings for safe fault clearing\u003c\/li\u003e\n\u003cli data-start=\"941\" data-end=\"983\"\u003eBolt-on mounting for secure installation\u003c\/li\u003e\n\u003cli data-start=\"986\" data-end=\"1100\"\u003eBase model image used for identification; accessories ordered with the breaker can be installed at no extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1107\" data-end=\"1135\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1138\" data-end=\"1175\"\u003eManufacturer: Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-start=\"1178\" data-end=\"1195\"\u003eFrame Style: ND\u003c\/li\u003e\n\u003cli data-start=\"1198\" data-end=\"1213\"\u003eFrame Type: N\u003c\/li\u003e\n\u003cli data-start=\"1216\" data-end=\"1245\"\u003eRated Current: 1200 Amperes\u003c\/li\u003e\n\u003cli data-start=\"1248\" data-end=\"1258\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-start=\"1261\" data-end=\"1287\"\u003eMaximum Voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"1290\" data-end=\"1311\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1314\" data-end=\"1337\"\u003eInterrupting Ratings:\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1342\" data-end=\"1359\"\u003e65 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1381\"\u003e50 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"1386\" data-end=\"1403\"\u003e25 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1439\"\u003eStandard Lug Type: Not included\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1463\"\u003eConnection: Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1466\" data-end=\"1486\"\u003eWarranty: One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1x5ej4z\" data-start=\"1493\" data-end=\"1512\"\u003eImportant Notes\u003c\/h3\u003e\n\u003cul data-start=\"1513\" data-end=\"1789\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"chj1cz\" data-start=\"1513\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1644\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1540\"\u003eRating Plug Required:\u003c\/strong\u003e The breaker will not operate without a rating plug. Confirm availability and pricing before ordering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zwsibb\" data-start=\"1645\" data-end=\"1789\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1789\" data-is-last-node=\"\"\u003eProduct image represents the base model only. Accessories ordered with the breaker can be installed to meet your specific configuration needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47486301339897,"sku":"ND312T36W-CR","price":8499.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47486301372665,"sku":"ND312T36W-NS","price":13499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/nd_4_1.webp?v=1772917187","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-nd312t36w-1200a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}