{"product_id":"eaton-cutler-hammer-ng3700s02-700a-3-pole-molded-case-generator-circuit-breaker-interchangeable-trip-unit-bolt-on-600vac","title":"Eaton Cutler Hammer NG3700S02 700A 3-Pole Molded Case Generator Circuit Breaker – Interchangeable Trip Unit – Bolt-On – 600VAC","description":"\u003cp data-start=\"176\" data-end=\"577\"\u003eThe \u003cstrong data-start=\"180\" data-end=\"215\"\u003eEaton \/ Cutler Hammer NG3700S02\u003c\/strong\u003e is a \u003cstrong data-start=\"221\" data-end=\"273\"\u003eheavy-duty molded case generator circuit breaker\u003c\/strong\u003e designed for reliable protection of generator-powered electrical systems. Built on the \u003cstrong data-start=\"361\" data-end=\"382\"\u003eNG frame platform\u003c\/strong\u003e, it features an \u003cstrong data-start=\"399\" data-end=\"439\"\u003eelectronic interchangeable trip unit\u003c\/strong\u003e with an adjustable \u003cstrong data-start=\"459\" data-end=\"493\"\u003etrip range of 500–2500 amperes\u003c\/strong\u003e, allowing flexible protection settings to suit varying generator load conditions.\u003c\/p\u003e\n\u003cp data-start=\"579\" data-end=\"1057\"\u003eRated at \u003cstrong data-start=\"588\" data-end=\"611\"\u003e700 amperes at 40°C\u003c\/strong\u003e, this \u003cstrong data-start=\"618\" data-end=\"640\"\u003ethree-pole breaker\u003c\/strong\u003e operates at \u003cstrong data-start=\"653\" data-end=\"674\"\u003e600VAC (50\/60 Hz)\u003c\/strong\u003e and is suitable for demanding industrial and commercial generator installations. The \u003cstrong data-start=\"760\" data-end=\"781\"\u003eS02 configuration\u003c\/strong\u003e includes a \u003cstrong data-start=\"793\" data-end=\"841\"\u003efactory-installed 9–24 VAC or VDC shunt trip\u003c\/strong\u003e, mounted on the \u003cstrong data-start=\"858\" data-end=\"888\"\u003eleft pole with a rear exit\u003c\/strong\u003e, enabling remote tripping functionality for enhanced system control and safety. The breaker is supplied \u003cstrong data-start=\"993\" data-end=\"1023\"\u003ewith terminals as standard\u003c\/strong\u003e for easy and secure installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1dqbs77\" data-start=\"1064\" data-end=\"1090\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1093\" data-end=\"1134\"\u003e\n\u003cstrong data-start=\"1093\" data-end=\"1110\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-start=\"1137\" data-end=\"1159\"\u003e\n\u003cstrong data-start=\"1137\" data-end=\"1147\"\u003eModel:\u003c\/strong\u003e NG3700S02\u003c\/li\u003e\n\u003cli data-start=\"1162\" data-end=\"1219\"\u003e\n\u003cstrong data-start=\"1162\" data-end=\"1179\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Generator Circuit Breaker\u003c\/li\u003e\n\u003cli data-start=\"1222\" data-end=\"1249\"\u003e\n\u003cstrong data-start=\"1222\" data-end=\"1238\"\u003eFrame Style:\u003c\/strong\u003e NG Frame\u003c\/li\u003e\n\u003cli data-start=\"1252\" data-end=\"1271\"\u003e\n\u003cstrong data-start=\"1252\" data-end=\"1267\"\u003eFrame Type:\u003c\/strong\u003e N\u003c\/li\u003e\n\u003cli data-start=\"1274\" data-end=\"1306\"\u003e\n\u003cstrong data-start=\"1274\" data-end=\"1292\"\u003eRated Current:\u003c\/strong\u003e 700 Amperes\u003c\/li\u003e\n\u003cli data-start=\"1309\" data-end=\"1338\"\u003e\n\u003cstrong data-start=\"1309\" data-end=\"1329\"\u003eNumber of Poles:\u003c\/strong\u003e 3 Pole\u003c\/li\u003e\n\u003cli data-start=\"1341\" data-end=\"1399\"\u003e\n\u003cstrong data-start=\"1341\" data-end=\"1360\"\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Interchangeable Trip Unit\u003c\/li\u003e\n\u003cli data-start=\"1402\" data-end=\"1432\"\u003e\n\u003cstrong data-start=\"1402\" data-end=\"1417\"\u003eTrip Range:\u003c\/strong\u003e 500 – 2500 A\u003c\/li\u003e\n\u003cli data-start=\"1435\" data-end=\"1465\"\u003e\n\u003cstrong data-start=\"1435\" data-end=\"1455\"\u003eConnection Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1468\" data-end=\"1522\"\u003e\n\u003cstrong data-start=\"1468\" data-end=\"1486\"\u003eConfiguration:\u003c\/strong\u003e S02 Option (Shunt Trip Installed)\u003c\/li\u003e\n\u003cli data-start=\"1525\" data-end=\"1560\"\u003e\n\u003cstrong data-start=\"1525\" data-end=\"1549\"\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1611\"\u003e\n\u003cstrong data-start=\"1563\" data-end=\"1585\"\u003eStandard Lug Type:\u003c\/strong\u003e With Terminals Standard\u003c\/li\u003e\n\u003cli data-start=\"1614\" data-end=\"1638\"\u003e\n\u003cstrong data-start=\"1614\" data-end=\"1627\"\u003eWarranty:\u003c\/strong\u003e One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1645\" data-end=\"1673\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1676\" data-end=\"1736\"\u003e\n\u003cstrong data-start=\"1676\" data-end=\"1705\"\u003eCircuit Breaker Category:\u003c\/strong\u003e Generator Protection Breaker\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1782\"\u003e\n\u003cstrong data-start=\"1739\" data-end=\"1759\"\u003eMounting Method:\u003c\/strong\u003e Bolt-On Installation\u003c\/li\u003e\n\u003cli data-start=\"1785\" data-end=\"1852\"\u003e\n\u003cstrong data-start=\"1785\" data-end=\"1805\"\u003eTrip Technology:\u003c\/strong\u003e Electronic Interchangeable Protection System\u003c\/li\u003e\n\u003cli data-start=\"1855\" data-end=\"1895\"\u003e\n\u003cstrong data-start=\"1855\" data-end=\"1888\"\u003eOperating Temperature Rating:\u003c\/strong\u003e 40°C\u003c\/li\u003e\n\u003cli data-start=\"1898\" data-end=\"1952\"\u003e\n\u003cstrong data-start=\"1898\" data-end=\"1921\"\u003eFrame Construction:\u003c\/strong\u003e NG Series Molded Case Design\u003c\/li\u003e\n\u003cli data-start=\"1955\" data-end=\"2041\"\u003e\n\u003cstrong data-start=\"1955\" data-end=\"1971\"\u003eApplication:\u003c\/strong\u003e Generator distribution systems and industrial electrical protection\u003c\/li\u003e\n\u003cli data-start=\"2044\" data-end=\"2069\"\u003e\u003cstrong data-start=\"2044\" data-end=\"2067\"\u003eShunt Trip Details:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"2074\" data-end=\"2109\"\u003e9–24 VAC or VDC operating voltage\u003c\/li\u003e\n\u003cli data-start=\"2114\" data-end=\"2133\"\u003eLeft pole mounted\u003c\/li\u003e\n\u003cli data-start=\"2138\" data-end=\"2169\"\u003eRear cable exit configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1vn2na3\" data-start=\"2176\" data-end=\"2199\"\u003eVoltage and Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2202\" data-end=\"2242\"\u003e\n\u003cstrong data-start=\"2202\" data-end=\"2232\"\u003eMaximum Operating Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"2245\" data-end=\"2273\"\u003e\u003cstrong data-start=\"2245\" data-end=\"2271\"\u003eInterrupting Capacity:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"2278\" data-end=\"2295\"\u003e18 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"2300\" data-end=\"2317\"\u003e14 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"2322\" data-end=\"2339\"\u003e10 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2346\" data-end=\"2362\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2365\" data-end=\"2420\"\u003e\n\u003cstrong data-start=\"2365\" data-end=\"2384\"\u003eProduct Series:\u003c\/strong\u003e Eaton NG Generator Breaker Series\u003c\/li\u003e\n\u003cli data-start=\"2423\" data-end=\"2449\"\u003e\n\u003cstrong data-start=\"2423\" data-end=\"2441\"\u003eRated Current:\u003c\/strong\u003e 700 A\u003c\/li\u003e\n\u003cli data-start=\"2452\" data-end=\"2498\"\u003e\n\u003cstrong data-start=\"2452\" data-end=\"2476\"\u003ePhase Compatibility:\u003c\/strong\u003e Three-Phase Systems\u003c\/li\u003e\n\u003cli data-start=\"2501\" data-end=\"2537\"\u003e\n\u003cstrong data-start=\"2501\" data-end=\"2526\"\u003eElectrical Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"2540\" data-end=\"2593\"\u003e\n\u003cstrong data-start=\"2540\" data-end=\"2567\"\u003eTerminal Configuration:\u003c\/strong\u003e With Terminals Standard\u003c\/li\u003e\n\u003cli data-start=\"2596\" data-end=\"2640\"\u003e\n\u003cstrong data-start=\"2596\" data-end=\"2618\"\u003eInstallation Type:\u003c\/strong\u003e Bolt-On Panel Mount\u003c\/li\u003e\n\u003cli data-start=\"2643\" data-end=\"2703\"\u003e\n\u003cstrong data-start=\"2643\" data-end=\"2668\"\u003eConfiguration Option:\u003c\/strong\u003e S02 Shunt Trip Factory Installed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"lgtwr4\" data-start=\"2710\" data-end=\"2728\"\u003eImportant Note\u003c\/h3\u003e\n\u003cp data-start=\"2729\" data-end=\"3206\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image shown represents a \u003cstrong data-start=\"2766\" data-end=\"2813\"\u003ebase model for identification purposes only\u003c\/strong\u003e and may not reflect the exact configuration supplied. If accessories or additional components are ordered together with the circuit breaker, they can be \u003cstrong data-start=\"2967\" data-end=\"3043\"\u003einstalled according to your required configuration at no additional cost\u003c\/strong\u003e. Please provide the necessary installation details in the \u003cstrong data-start=\"3102\" data-end=\"3143\"\u003eorder comment section during checkout\u003c\/strong\u003e to ensure the breaker is configured correctly before shipment.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47487845204217,"sku":"NG3700S02-CR","price":8200.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47487845236985,"sku":"NG3700S03-NS","price":15499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/NG3700S02.webp?v=1772981201","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-ng3700s02-700a-3-pole-molded-case-generator-circuit-breaker-interchangeable-trip-unit-bolt-on-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}