{"product_id":"eaton-cutler-hammer-ng3700w-700a-3-pole-molded-case-generator-circuit-breaker-interchangeable-trip-unit-bolt-on-600vac","title":"Eaton Cutler Hammer NG3700W 700A 3-Pole Molded Case Generator Circuit Breaker – Interchangeable Trip Unit – Bolt-On – 600VAC","description":"\u003cp data-start=\"174\" data-end=\"602\"\u003eThe \u003cstrong data-start=\"178\" data-end=\"211\"\u003eEaton \/ Cutler Hammer NG3700W\u003c\/strong\u003e is a \u003cstrong data-start=\"217\" data-end=\"266\"\u003edurable molded case generator circuit breaker\u003c\/strong\u003e designed to provide reliable protection for generator-based electrical distribution systems. Built on the rugged \u003cstrong data-start=\"380\" data-end=\"401\"\u003eNG frame platform\u003c\/strong\u003e, this breaker features an \u003cstrong data-start=\"428\" data-end=\"468\"\u003eelectronic interchangeable trip unit\u003c\/strong\u003e with an adjustable \u003cstrong data-start=\"488\" data-end=\"522\"\u003etrip range of 500–2500 amperes\u003c\/strong\u003e, enabling flexible protection settings for varying generator load conditions.\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"960\"\u003eRated at \u003cstrong data-start=\"613\" data-end=\"636\"\u003e700 amperes at 40°C\u003c\/strong\u003e, this \u003cstrong data-start=\"643\" data-end=\"673\"\u003ethree-pole circuit breaker\u003c\/strong\u003e operates at \u003cstrong data-start=\"686\" data-end=\"707\"\u003e600VAC (50\/60 Hz)\u003c\/strong\u003e and is suitable for demanding industrial and commercial generator installations. The \u003cstrong data-start=\"793\" data-end=\"804\"\u003eNG3700W\u003c\/strong\u003e model is supplied \u003cstrong data-start=\"823\" data-end=\"856\"\u003ewithout terminals as standard\u003c\/strong\u003e, allowing installers to configure terminal connections according to specific installation requirements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1dqbs77\" data-start=\"967\" data-end=\"993\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"996\" data-end=\"1037\"\u003e\n\u003cstrong data-start=\"996\" data-end=\"1013\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler Hammer\u003c\/li\u003e\n\u003cli data-start=\"1040\" data-end=\"1060\"\u003e\n\u003cstrong data-start=\"1040\" data-end=\"1050\"\u003eModel:\u003c\/strong\u003e NG3700W\u003c\/li\u003e\n\u003cli data-start=\"1063\" data-end=\"1120\"\u003e\n\u003cstrong data-start=\"1063\" data-end=\"1080\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Generator Circuit Breaker\u003c\/li\u003e\n\u003cli data-start=\"1123\" data-end=\"1150\"\u003e\n\u003cstrong data-start=\"1123\" data-end=\"1139\"\u003eFrame Style:\u003c\/strong\u003e NG Frame\u003c\/li\u003e\n\u003cli data-start=\"1153\" data-end=\"1172\"\u003e\n\u003cstrong data-start=\"1153\" data-end=\"1168\"\u003eFrame Type:\u003c\/strong\u003e N\u003c\/li\u003e\n\u003cli data-start=\"1175\" data-end=\"1207\"\u003e\n\u003cstrong data-start=\"1175\" data-end=\"1193\"\u003eRated Current:\u003c\/strong\u003e 700 Amperes\u003c\/li\u003e\n\u003cli data-start=\"1210\" data-end=\"1239\"\u003e\n\u003cstrong data-start=\"1210\" data-end=\"1230\"\u003eNumber of Poles:\u003c\/strong\u003e 3 Pole\u003c\/li\u003e\n\u003cli data-start=\"1242\" data-end=\"1300\"\u003e\n\u003cstrong data-start=\"1242\" data-end=\"1261\"\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Interchangeable Trip Unit\u003c\/li\u003e\n\u003cli data-start=\"1303\" data-end=\"1333\"\u003e\n\u003cstrong data-start=\"1303\" data-end=\"1318\"\u003eTrip Range:\u003c\/strong\u003e 500 – 2500 A\u003c\/li\u003e\n\u003cli data-start=\"1336\" data-end=\"1366\"\u003e\n\u003cstrong data-start=\"1336\" data-end=\"1356\"\u003eConnection Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1369\" data-end=\"1404\"\u003e\n\u003cstrong data-start=\"1369\" data-end=\"1393\"\u003eOperating Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1407\" data-end=\"1458\"\u003e\n\u003cstrong data-start=\"1407\" data-end=\"1429\"\u003eStandard Lug Type:\u003c\/strong\u003e Without Terminals Standard\u003c\/li\u003e\n\u003cli data-start=\"1461\" data-end=\"1485\"\u003e\n\u003cstrong data-start=\"1461\" data-end=\"1474\"\u003eWarranty:\u003c\/strong\u003e One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1492\" data-end=\"1520\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1523\" data-end=\"1583\"\u003e\n\u003cstrong data-start=\"1523\" data-end=\"1552\"\u003eCircuit Breaker Category:\u003c\/strong\u003e Generator Protection Breaker\u003c\/li\u003e\n\u003cli data-start=\"1586\" data-end=\"1629\"\u003e\n\u003cstrong data-start=\"1586\" data-end=\"1606\"\u003eMounting Method:\u003c\/strong\u003e Bolt-On Installation\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1699\"\u003e\n\u003cstrong data-start=\"1632\" data-end=\"1652\"\u003eTrip Technology:\u003c\/strong\u003e Electronic Interchangeable Protection System\u003c\/li\u003e\n\u003cli data-start=\"1702\" data-end=\"1742\"\u003e\n\u003cstrong data-start=\"1702\" data-end=\"1735\"\u003eOperating Temperature Rating:\u003c\/strong\u003e 40°C\u003c\/li\u003e\n\u003cli data-start=\"1745\" data-end=\"1799\"\u003e\n\u003cstrong data-start=\"1745\" data-end=\"1768\"\u003eFrame Construction:\u003c\/strong\u003e NG Series Molded Case Design\u003c\/li\u003e\n\u003cli data-start=\"1802\" data-end=\"1888\"\u003e\n\u003cstrong data-start=\"1802\" data-end=\"1818\"\u003eApplication:\u003c\/strong\u003e Generator distribution systems and industrial electrical protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1vn2na3\" data-start=\"1895\" data-end=\"1918\"\u003eVoltage and Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1921\" data-end=\"1961\"\u003e\n\u003cstrong data-start=\"1921\" data-end=\"1951\"\u003eMaximum Operating Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"1964\" data-end=\"1992\"\u003e\u003cstrong data-start=\"1964\" data-end=\"1990\"\u003eInterrupting Capacity:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1997\" data-end=\"2014\"\u003e18 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"2019\" data-end=\"2036\"\u003e14 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"2041\" data-end=\"2058\"\u003e10 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2065\" data-end=\"2081\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2084\" data-end=\"2139\"\u003e\n\u003cstrong data-start=\"2084\" data-end=\"2103\"\u003eProduct Series:\u003c\/strong\u003e Eaton NG Generator Breaker Series\u003c\/li\u003e\n\u003cli data-start=\"2142\" data-end=\"2168\"\u003e\n\u003cstrong data-start=\"2142\" data-end=\"2160\"\u003eRated Current:\u003c\/strong\u003e 700 A\u003c\/li\u003e\n\u003cli data-start=\"2171\" data-end=\"2217\"\u003e\n\u003cstrong data-start=\"2171\" data-end=\"2195\"\u003ePhase Compatibility:\u003c\/strong\u003e Three-Phase Systems\u003c\/li\u003e\n\u003cli data-start=\"2220\" data-end=\"2256\"\u003e\n\u003cstrong data-start=\"2220\" data-end=\"2245\"\u003eElectrical Frequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"2259\" data-end=\"2327\"\u003e\n\u003cstrong data-start=\"2259\" data-end=\"2286\"\u003eTerminal Configuration:\u003c\/strong\u003e Without Terminals (Field Configurable)\u003c\/li\u003e\n\u003cli data-start=\"2330\" data-end=\"2374\"\u003e\n\u003cstrong data-start=\"2330\" data-end=\"2352\"\u003eInstallation Type:\u003c\/strong\u003e Bolt-On Panel Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"lgtwr4\" data-start=\"2381\" data-end=\"2399\"\u003eImportant Note\u003c\/h3\u003e\n\u003cp data-start=\"2400\" data-end=\"2865\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image shown represents a \u003cstrong data-start=\"2437\" data-end=\"2484\"\u003ebase model for identification purposes only\u003c\/strong\u003e and may not reflect the exact configuration supplied. If accessories or additional components are ordered together with the breaker, they can be \u003cstrong data-start=\"2630\" data-end=\"2702\"\u003einstalled to match your required configuration at no additional cost\u003c\/strong\u003e. Please include the necessary installation details in the \u003cstrong data-start=\"2761\" data-end=\"2802\"\u003eorder comment section during checkout\u003c\/strong\u003e to ensure the breaker is configured correctly before shipment.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47487903138041,"sku":"NG3700W-CR","price":7400.0,"currency_code":"USD","in_stock":true},{"title":"New Surplus","offer_id":47487903170809,"sku":"NG3700W-NS","price":14699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/NG3700W.webp?v=1772982007","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-ng3700w-700a-3-pole-molded-case-generator-circuit-breaker-interchangeable-trip-unit-bolt-on-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}