{"product_id":"eaton-cutler-hammer-rd320t35wq02-2000a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"Eaton Cutler-Hammer RD320T35WQ02 2000A 3 Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-start=\"153\" data-end=\"477\"\u003eThe Eaton Cutler-Hammer RD320T35WQ02 is a high-capacity molded case circuit breaker engineered for industrial and commercial electrical systems. Built on the RD R-Frame platform with the \u003cstrong data-start=\"340\" data-end=\"381\"\u003eDigitrip RMS 310 electronic trip unit\u003c\/strong\u003e, it provides reliable protection against overloads, short circuits, and instantaneous faults.\u003c\/p\u003e\n\u003cp data-start=\"479\" data-end=\"757\"\u003eFeaturing \u003cstrong data-start=\"489\" data-end=\"517\"\u003eLSG protection functions\u003c\/strong\u003e (Long Delay, Short Delay, Ground Fault), this version is specifically designed \u003cstrong data-start=\"597\" data-end=\"649\"\u003ewithout the ground fault terminal block and coil\u003c\/strong\u003e, making it suitable for applications where remote ground fault sensing or auxiliary wiring is not required.\u003c\/p\u003e\n\u003ch4 data-start=\"764\" data-end=\"790\"\u003eVoltage and Ratings\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"793\" data-end=\"826\"\u003eRated Current: \u003cstrong data-start=\"808\" data-end=\"824\"\u003e2000 Amperes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"829\" data-end=\"859\"\u003eMaximum Voltage: \u003cstrong data-start=\"846\" data-end=\"857\"\u003e600 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"862\" data-end=\"887\"\u003eFrequency: \u003cstrong data-start=\"873\" data-end=\"885\"\u003e50\/60 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"890\" data-end=\"914\"\u003eInterrupting Capacity:\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"919\" data-end=\"942\"\u003e\u003cstrong data-start=\"919\" data-end=\"940\"\u003e125 kA at 240 VAC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"947\" data-end=\"969\"\u003e\u003cstrong data-start=\"947\" data-end=\"967\"\u003e65 kA at 480 VAC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"996\"\u003e\u003cstrong data-start=\"974\" data-end=\"994\"\u003e50 kA at 600 VAC\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1038\"\u003eTemperature Rating: \u003cstrong data-start=\"1019\" data-end=\"1036\"\u003e2000A at 40°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1041\" data-end=\"1100\"\u003eApplication Rating: \u003cstrong data-start=\"1061\" data-end=\"1100\"\u003eRated for 100% continuous operation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1107\" data-end=\"1132\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1135\" data-end=\"1201\"\u003e\n\u003cstrong data-start=\"1135\" data-end=\"1176\"\u003eDigitrip RMS 310 electronic trip unit\u003c\/strong\u003e for precise protection\u003c\/li\u003e\n\u003cli data-start=\"1204\" data-end=\"1304\"\u003e\n\u003cstrong data-start=\"1204\" data-end=\"1232\"\u003eLSG protection functions\u003c\/strong\u003e (Long Delay, Short Delay, Ground Fault – without terminal block\/coil)\u003c\/li\u003e\n\u003cli data-start=\"1307\" data-end=\"1353\"\u003eAdjustable long-delay pickup via rating plug\u003c\/li\u003e\n\u003cli data-start=\"1356\" data-end=\"1417\"\u003eShort-delay protection with selectable I²t or flat response\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1491\"\u003eOptimized for high interrupting capacity and heavy-duty power systems\u003c\/li\u003e\n\u003cli data-start=\"1494\" data-end=\"1574\"\u003eStreamlined design without ground fault accessories for specific installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1581\" data-end=\"1612\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"1615\" data-end=\"1669\"\u003eBreaker Type: \u003cstrong data-start=\"1629\" data-end=\"1667\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1704\"\u003eModel Number: \u003cstrong data-start=\"1686\" data-end=\"1702\"\u003eRD320T35WQ02\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1707\" data-end=\"1732\"\u003eFrame Type: \u003cstrong data-start=\"1719\" data-end=\"1730\"\u003eR Frame\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1735\" data-end=\"1806\"\u003eTrip Unit Type: \u003cstrong data-start=\"1751\" data-end=\"1804\"\u003eElectronic Non-Interchangeable – Digitrip RMS 310\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1809\" data-end=\"1910\"\u003eProtection Functions: \u003cstrong data-start=\"1831\" data-end=\"1908\"\u003eLSG (Long Delay, Short Delay, Ground Fault – without coil\/terminal block)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1913\" data-end=\"1964\"\u003eLong Delay Pickup: \u003cstrong data-start=\"1932\" data-end=\"1962\"\u003eAdjustable via rating plug\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1967\" data-end=\"2026\"\u003eShort Delay Response: \u003cstrong data-start=\"1989\" data-end=\"2024\"\u003eI²t or flat response selectable\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2029\" data-end=\"2085\"\u003eTrip Setting Range: \u003cstrong data-start=\"2049\" data-end=\"2083\"\u003e2–8 × Continuous Ampere Rating\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2088\" data-end=\"2117\"\u003eNumber of Poles: \u003cstrong data-start=\"2105\" data-end=\"2115\"\u003e3 Pole\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2120\" data-end=\"2148\"\u003eConnection Type: \u003cstrong data-start=\"2137\" data-end=\"2148\"\u003eBolt-On\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"2155\" data-end=\"2174\"\u003eProduct Data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"2177\" data-end=\"2218\"\u003eManufacturer: \u003cstrong data-start=\"2191\" data-end=\"2216\"\u003eEaton \/ Cutler Hammer\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2221\" data-end=\"2237\"\u003eSeries: \u003cstrong data-start=\"2229\" data-end=\"2235\"\u003eRD\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2240\" data-end=\"2266\"\u003eRated Current: \u003cstrong data-start=\"2255\" data-end=\"2264\"\u003e2000A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2269\" data-end=\"2298\"\u003eMaximum Voltage: \u003cstrong data-start=\"2286\" data-end=\"2296\"\u003e600VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2301\" data-end=\"2342\"\u003eMounting Type: \u003cstrong data-start=\"2316\" data-end=\"2340\"\u003eBolt-On Installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2345\" data-end=\"2365\"\u003eWarranty: \u003cstrong data-start=\"2355\" data-end=\"2365\"\u003e1 Year\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2367\" data-end=\"2541\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2367\" data-end=\"2388\"\u003eImportant Notice:\u003c\/strong\u003e\u003cbr data-start=\"2388\" data-end=\"2391\"\u003eThis breaker requires a \u003cstrong data-start=\"2415\" data-end=\"2430\"\u003erating plug\u003c\/strong\u003e to operate. Accessories can be pre-installed to configure the breaker for your specific application needs.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47482944782585,"sku":"RD320T35WQ02","price":13999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/rd320t35w_1_00ae059f-ed2d-48f0-a3fc-8d170e0eb686.webp?v=1772832349","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-rd320t35wq02-2000a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}