{"product_id":"eaton-cutler-hammer-rd325t36w-2500a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"Eaton Cutler-Hammer RD325T36W 2500A 3 Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-start=\"149\" data-end=\"520\"\u003eThe \u003cstrong data-start=\"153\" data-end=\"186\"\u003eEaton Cutler-Hammer RD325T36W\u003c\/strong\u003e molded case circuit breaker is designed for demanding electrical distribution systems in commercial and industrial environments. Built on the \u003cstrong data-start=\"329\" data-end=\"349\"\u003eR-frame platform\u003c\/strong\u003e, this breaker incorporates the \u003cstrong data-start=\"381\" data-end=\"422\"\u003eDigitrip RMS 310 electronic trip unit\u003c\/strong\u003e with advanced protection functions to ensure reliable circuit protection and system coordination.\u003c\/p\u003e\n\u003cp data-start=\"522\" data-end=\"872\"\u003eThis model provides \u003cstrong data-start=\"542\" data-end=\"561\"\u003eLSIG protection\u003c\/strong\u003e (Long Delay, Short Delay, Instantaneous, and Ground Fault), allowing detailed adjustment of protection settings to match system requirements. With a \u003cstrong data-start=\"711\" data-end=\"738\"\u003e2500-amp rating at 40°C\u003c\/strong\u003e, the breaker delivers dependable protection against overloads, short circuits, and ground faults in high-capacity power applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1x9asb\" data-start=\"879\" data-end=\"904\"\u003eVoltage and Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"907\" data-end=\"940\"\u003e\n\u003cstrong data-start=\"907\" data-end=\"925\"\u003eRated Current:\u003c\/strong\u003e 2500 Amperes\u003c\/li\u003e\n\u003cli data-start=\"943\" data-end=\"973\"\u003e\n\u003cstrong data-start=\"943\" data-end=\"963\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"976\" data-end=\"1001\"\u003e\n\u003cstrong data-start=\"976\" data-end=\"990\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-start=\"1004\" data-end=\"1032\"\u003e\u003cstrong data-start=\"1004\" data-end=\"1030\"\u003eInterrupting Capacity:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli\u003e125 kA at 240 VAC\u003c\/li\u003e\n\u003cli\u003e65 kA at 480 VAC\u003c\/li\u003e\n\u003cli\u003e50 kA at 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-start=\"1105\" data-end=\"1128\"\u003eTemperature Rating:\u003c\/strong\u003e 2500A at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ltslzz\" data-start=\"1151\" data-end=\"1175\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1178\" data-end=\"1244\"\u003e\n\u003cstrong data-start=\"1178\" data-end=\"1192\"\u003eTrip Unit:\u003c\/strong\u003e Digitrip RMS 310 Electronic (Non-Interchangeable)\u003c\/li\u003e\n\u003cli data-start=\"1247\" data-end=\"1281\"\u003e\u003cstrong data-start=\"1247\" data-end=\"1279\"\u003eProtection Functions (LSIG):\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"1286\" data-end=\"1341\"\u003e\n\u003cstrong data-start=\"1286\" data-end=\"1312\"\u003eL – Long Delay Pickup:\u003c\/strong\u003e Adjustable via rating plug\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1430\"\u003e\n\u003cstrong data-start=\"1346\" data-end=\"1373\"\u003eS – Short Delay Pickup:\u003c\/strong\u003e Adjustable with selectable I²t or flat response timing\u003c\/li\u003e\n\u003cli data-start=\"1435\" data-end=\"1502\"\u003e\n\u003cstrong data-start=\"1435\" data-end=\"1468\"\u003eI – Instantaneous Protection:\u003c\/strong\u003e Adjustable instantaneous pickup\u003c\/li\u003e\n\u003cli data-start=\"1507\" data-end=\"1585\"\u003e\n\u003cstrong data-start=\"1507\" data-end=\"1539\"\u003eG – Ground Fault Protection:\u003c\/strong\u003e Adjustable pickup and delay (flat response)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1588\" data-end=\"1645\"\u003e\n\u003cstrong data-start=\"1588\" data-end=\"1611\"\u003eTrip Setting Range:\u003c\/strong\u003e 2–8 × continuous current rating\u003c\/li\u003e\n\u003cli data-start=\"1648\" data-end=\"1725\"\u003eDesigned for precise coordination and enhanced electrical system protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"12xlpaz\" data-start=\"1732\" data-end=\"1762\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1765\" data-end=\"1819\"\u003e\n\u003cstrong data-start=\"1765\" data-end=\"1782\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-start=\"1822\" data-end=\"1863\"\u003e\n\u003cstrong data-start=\"1822\" data-end=\"1841\"\u003eSeries \/ Frame:\u003c\/strong\u003e RD Series – R Frame\u003c\/li\u003e\n\u003cli data-start=\"1866\" data-end=\"1895\"\u003e\n\u003cstrong data-start=\"1866\" data-end=\"1883\"\u003eModel Number:\u003c\/strong\u003e RD325T36W\u003c\/li\u003e\n\u003cli data-start=\"1898\" data-end=\"1924\"\u003e\n\u003cstrong data-start=\"1898\" data-end=\"1916\"\u003eRated Current:\u003c\/strong\u003e 2500A\u003c\/li\u003e\n\u003cli data-start=\"1927\" data-end=\"1946\"\u003e\n\u003cstrong data-start=\"1927\" data-end=\"1937\"\u003ePoles:\u003c\/strong\u003e 3 Pole\u003c\/li\u003e\n\u003cli data-start=\"1949\" data-end=\"1979\"\u003e\n\u003cstrong data-start=\"1949\" data-end=\"1969\"\u003eConnection Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"1982\" data-end=\"2012\"\u003e\n\u003cstrong data-start=\"1982\" data-end=\"2002\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tq7vdp\" data-start=\"2019\" data-end=\"2037\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2040\" data-end=\"2081\"\u003e\n\u003cstrong data-start=\"2040\" data-end=\"2057\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"2084\" data-end=\"2103\"\u003e\n\u003cstrong data-start=\"2084\" data-end=\"2099\"\u003eFrame Type:\u003c\/strong\u003e R\u003c\/li\u003e\n\u003cli data-start=\"2106\" data-end=\"2136\"\u003e\n\u003cstrong data-start=\"2106\" data-end=\"2126\"\u003eMounting Method:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"2139\" data-end=\"2161\"\u003e\n\u003cstrong data-start=\"2139\" data-end=\"2152\"\u003eWarranty:\u003c\/strong\u003e 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2163\" data-end=\"2472\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2163\" data-end=\"2184\"\u003eImportant Notice:\u003c\/strong\u003e\u003cbr data-start=\"2184\" data-end=\"2187\"\u003eA \u003cstrong data-start=\"2189\" data-end=\"2216\"\u003erating plug is required\u003c\/strong\u003e for proper operation of this breaker. Please confirm availability and required amp rating before ordering. If ordered together with accessories, they can be factory-installed to match your configuration requirements at no additional installation cost.\u003c\/p\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47483201913081,"sku":"RD325T36W","price":19099.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/rd_1_29_24.webp?v=1772839841","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-rd325t36w-2500a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}