{"product_id":"eaton-cutler-hammer-rdc316t33wp02s29y01-1600a-3-pole-molded-case-circuit-breaker-bolt-on-600v","title":"Eaton Cutler-Hammer RDC316T33WP02S29Y01 1600A 3-Pole Molded Case Circuit Breaker – Bolt-On – 600V","description":"\u003cp data-start=\"403\" data-end=\"801\"\u003eThe \u003cstrong data-start=\"407\" data-end=\"458\"\u003eRDC316T33WP02S29Y01 molded case circuit breaker\u003c\/strong\u003e from Eaton \/ Cutler-Hammer is built for demanding electrical distribution systems where dependable protection and coordination are essential. This breaker is part of the \u003cstrong data-start=\"629\" data-end=\"647\"\u003eR-Frame series\u003c\/strong\u003e and features an \u003cstrong data-start=\"664\" data-end=\"705\"\u003eelectronic Digitrip RMS 310 trip unit\u003c\/strong\u003e, designed to provide consistent monitoring and tripping accuracy under varying load conditions.\u003c\/p\u003e\n\u003cp data-start=\"803\" data-end=\"1235\"\u003eThe unit offers \u003cstrong data-start=\"819\" data-end=\"846\"\u003eLS protection functions\u003c\/strong\u003e, including adjustable long-delay and short-delay settings. The long-delay pickup level is configured through a \u003cstrong data-start=\"958\" data-end=\"973\"\u003erating plug\u003c\/strong\u003e, which determines the continuous current rating and must be installed for the breaker to operate. Short-delay protection can be configured with either \u003cstrong data-start=\"1125\" data-end=\"1141\"\u003eI²t response\u003c\/strong\u003e for coordinated protection or \u003cstrong data-start=\"1172\" data-end=\"1189\"\u003eflat response\u003c\/strong\u003e for faster clearing in specific applications.\u003c\/p\u003e\n\u003cp data-start=\"1237\" data-end=\"1404\"\u003eThis configuration also includes factory-installed option codes \u003cstrong data-start=\"1301\" data-end=\"1322\"\u003eP02, S29, and Y01\u003c\/strong\u003e, providing additional configuration flexibility depending on system requirements.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ihrae0\" data-start=\"127\" data-end=\"149\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"152\" data-end=\"204\"\u003e\n\u003cstrong data-start=\"152\" data-end=\"171\"\u003eCurrent Rating:\u003c\/strong\u003e 1600 Amps (calibrated at 40°C)\u003c\/li\u003e\n\u003cli data-start=\"207\" data-end=\"221\"\u003e\n\u003cstrong data-start=\"207\" data-end=\"217\"\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-start=\"224\" data-end=\"254\"\u003e\n\u003cstrong data-start=\"224\" data-end=\"244\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"257\" data-end=\"282\"\u003e\n\u003cstrong data-start=\"257\" data-end=\"271\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"284\" data-end=\"309\"\u003e\u003cstrong data-start=\"284\" data-end=\"309\"\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"312\" data-end=\"331\"\u003e200 kA at 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"334\" data-end=\"353\"\u003e100 kA at 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"356\" data-end=\"374\"\u003e65 kA at 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1411\" data-end=\"1438\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1441\" data-end=\"1499\"\u003e\n\u003cstrong data-start=\"1441\" data-end=\"1462\"\u003eBreaker Category:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-start=\"1502\" data-end=\"1535\"\u003e\n\u003cstrong data-start=\"1502\" data-end=\"1519\"\u003eFrame Series:\u003c\/strong\u003e RDC \/ R-Frame\u003c\/li\u003e\n\u003cli data-start=\"1538\" data-end=\"1610\"\u003e\n\u003cstrong data-start=\"1538\" data-end=\"1557\"\u003eTrip Unit Type:\u003c\/strong\u003e Digitrip RMS 310 (Electronic, Non-Interchangeable)\u003c\/li\u003e\n\u003cli data-start=\"1613\" data-end=\"1672\"\u003e\n\u003cstrong data-start=\"1613\" data-end=\"1638\"\u003eProtection Functions:\u003c\/strong\u003e LS – Long Delay and Short Delay\u003c\/li\u003e\n\u003cli data-start=\"1675\" data-end=\"1728\"\u003e\n\u003cstrong data-start=\"1675\" data-end=\"1697\"\u003eLong Delay Pickup:\u003c\/strong\u003e Adjustable using rating plug\u003c\/li\u003e\n\u003cli data-start=\"1731\" data-end=\"1799\"\u003e\n\u003cstrong data-start=\"1731\" data-end=\"1754\"\u003eShort Delay Pickup:\u003c\/strong\u003e Adjustable with I²t or flat response curve\u003c\/li\u003e\n\u003cli data-start=\"1802\" data-end=\"1845\"\u003e\n\u003cstrong data-start=\"1802\" data-end=\"1822\"\u003eMounting Method:\u003c\/strong\u003e Bolt-On installation\u003c\/li\u003e\n\u003cli data-start=\"1848\" data-end=\"1906\"\u003e\n\u003cstrong data-start=\"1848\" data-end=\"1872\"\u003eConfiguration Codes:\u003c\/strong\u003e P02 \/ S29 \/ Y01 factory options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"we2dfi\" data-start=\"1913\" data-end=\"1928\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"1931\" data-end=\"1972\"\u003e\n\u003cstrong data-start=\"1931\" data-end=\"1948\"\u003eManufacturer:\u003c\/strong\u003e Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli data-start=\"1975\" data-end=\"2014\"\u003e\n\u003cstrong data-start=\"1975\" data-end=\"1992\"\u003eModel Number:\u003c\/strong\u003e RDC316T33WP02S29Y01\u003c\/li\u003e\n\u003cli data-start=\"2017\" data-end=\"2042\"\u003e\n\u003cstrong data-start=\"2017\" data-end=\"2032\"\u003eFrame Type:\u003c\/strong\u003e R Frame\u003c\/li\u003e\n\u003cli data-start=\"2045\" data-end=\"2072\"\u003e\n\u003cstrong data-start=\"2045\" data-end=\"2063\"\u003eRated Current:\u003c\/strong\u003e 1600 A\u003c\/li\u003e\n\u003cli data-start=\"2075\" data-end=\"2089\"\u003e\n\u003cstrong data-start=\"2075\" data-end=\"2085\"\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-start=\"2092\" data-end=\"2122\"\u003e\n\u003cstrong data-start=\"2092\" data-end=\"2112\"\u003eMaximum Voltage:\u003c\/strong\u003e 600 VAC\u003c\/li\u003e\n\u003cli data-start=\"2125\" data-end=\"2185\"\u003e\n\u003cstrong data-start=\"2125\" data-end=\"2151\"\u003eTrip Adjustment Range:\u003c\/strong\u003e 2–8 × continuous current rating\u003c\/li\u003e\n\u003cli data-start=\"2188\" data-end=\"2215\"\u003e\u003cstrong data-start=\"2188\" data-end=\"2213\"\u003eInterrupting Ratings:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli data-start=\"2220\" data-end=\"2238\"\u003e200 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-start=\"2243\" data-end=\"2261\"\u003e100 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-start=\"2266\" data-end=\"2283\"\u003e65 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2286\" data-end=\"2316\"\u003e\n\u003cstrong data-start=\"2286\" data-end=\"2306\"\u003eConnection Type:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli data-start=\"2319\" data-end=\"2341\"\u003e\n\u003cstrong data-start=\"2319\" data-end=\"2332\"\u003eWarranty:\u003c\/strong\u003e 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2343\" data-end=\"2362\"\u003e\u003cstrong data-start=\"2343\" data-end=\"2362\"\u003eImportant Notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2365\" data-end=\"2470\"\u003eA \u003cstrong data-start=\"2367\" data-end=\"2405\"\u003ecompatible rating plug is required\u003c\/strong\u003e for proper breaker operation and must be installed before use.\u003c\/li\u003e\n\u003cli data-start=\"2473\" data-end=\"2578\"\u003eProduct images typically show a \u003cstrong data-start=\"2505\" data-end=\"2533\"\u003estandard reference model\u003c\/strong\u003e and may vary from the exact configuration.\u003c\/li\u003e\n\u003cli data-start=\"2581\" data-end=\"2708\"\u003eIf accessories are ordered together with the breaker, they can be \u003cstrong data-start=\"2647\" data-end=\"2678\"\u003einstalled prior to shipment\u003c\/strong\u003e to match the requested setup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"Certified Reconditioned","offer_id":47483237400825,"sku":"RDC316T33WP02S29Y01","price":8599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/rd_1_1_14_57f3d3fa-7b2a-4204-a5ce-1261bf7ecd79.webp?v=1772841374","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cutler-hammer-rdc316t33wp02s29y01-1600a-3-pole-molded-case-circuit-breaker-bolt-on-600v","provider":"My Circuit Breakers","version":"1.0","type":"link"}