{"product_id":"eaton-cvs3200x-ccv-tenant-main-breaker-200a-3-pole-42-kaic","title":"Eaton CVS3200X CCV Tenant Main Breaker – 200A, 3-Pole, 42 kAIC","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a02164e-d728-83e9-913c-2b016ff57229-4\" data-turn-id-container=\"request-6a02164e-d728-83e9-913c-2b016ff57229-4\" data-testid=\"conversation-turn-250\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"4532211e-6594-4eed-a9e1-c725a7355a76\" dir=\"auto\" data-message-model-slug=\"gpt-5-5\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"121\" data-end=\"558\"\u003eThe Eaton CVS3200X CCV tenant main breaker is a molded case circuit breaker designed for commercial tenant main and power distribution applications. It provides reliable thermal magnetic protection against overloads and short-circuit conditions while supporting high interrupting capacity requirements. Its three-pole construction makes it suitable for multi-phase electrical systems in commercial environments.\u003c\/p\u003e\n\u003cp data-start=\"565\" data-end=\"587\"\u003e\u003cstrong data-start=\"565\" data-end=\"587\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"589\" data-end=\"756\"\u003e\n\u003cli data-section-id=\"17jx6g8\" data-start=\"589\" data-end=\"613\"\u003eCurrent Rating: 200A\u003c\/li\u003e\n\u003cli data-section-id=\"16th55b\" data-start=\"614\" data-end=\"645\"\u003eNumber of Poles: Three-pole\u003c\/li\u003e\n\u003cli data-section-id=\"o00bhv\" data-start=\"646\" data-end=\"675\"\u003eInterrupt Rating: 42 kAIC\u003c\/li\u003e\n\u003cli data-section-id=\"dqfmwu\" data-start=\"676\" data-end=\"710\"\u003eCircuit Breaker Frame Type: CV\u003c\/li\u003e\n\u003cli data-section-id=\"qlmkbl\" data-start=\"711\" data-end=\"756\"\u003eBreaker Type: Molded case circuit breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"763\" data-end=\"785\"\u003e\u003cstrong data-start=\"763\" data-end=\"785\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"787\" data-end=\"1135\"\u003e\n\u003cli data-section-id=\"104z54j\" data-start=\"787\" data-end=\"810\"\u003eManufacturer: Eaton\u003c\/li\u003e\n\u003cli data-section-id=\"16acfx6\" data-start=\"811\" data-end=\"839\"\u003eCatalog Number: CVS3200X\u003c\/li\u003e\n\u003cli data-section-id=\"zkvss3\" data-start=\"840\" data-end=\"861\"\u003eUPC: 786685704265\u003c\/li\u003e\n\u003cli data-section-id=\"16ayh35\" data-start=\"862\" data-end=\"899\"\u003eProduct Type: Tenant main breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1t6o6jo\" data-start=\"900\" data-end=\"943\"\u003eStandards: UL 489, CSA Std. C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"9kladq\" data-start=\"944\" data-end=\"981\"\u003eWire Size Range: #6–4\/0 AWG Cu\/Al\u003c\/li\u003e\n\u003cli data-section-id=\"10u9tab\" data-start=\"982\" data-end=\"1028\"\u003eTerminal Capacity: #4\/0 kcmil maximum load\u003c\/li\u003e\n\u003cli data-section-id=\"1n4ycdx\" data-start=\"1029\" data-end=\"1104\"\u003eApplication: Commercial tenant main and electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"plvh52\" data-start=\"1105\" data-end=\"1135\"\u003eWarranty: Limited lifetime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1142\" data-end=\"1162\"\u003e\u003cstrong data-start=\"1142\" data-end=\"1162\"\u003ePhysical Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1164\" data-end=\"1270\"\u003e\n\u003cli data-section-id=\"1yjprez\" data-start=\"1164\" data-end=\"1196\"\u003eProduct Length\/Depth: 7.5 in\u003c\/li\u003e\n\u003cli data-section-id=\"absrcj\" data-start=\"1197\" data-end=\"1221\"\u003eProduct Height: 5 in\u003c\/li\u003e\n\u003cli data-section-id=\"1vs05e2\" data-start=\"1222\" data-end=\"1245\"\u003eProduct Width: 5 in\u003c\/li\u003e\n\u003cli data-section-id=\"1tl18rp\" data-start=\"1246\" data-end=\"1270\"\u003eProduct Weight: 5 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1277\" data-end=\"1293\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1293\"\u003eProduct Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1295\" data-end=\"1630\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1llupqp\" data-start=\"1295\" data-end=\"1368\"\u003eApplication: Commercial power distribution and tenant main protection\u003c\/li\u003e\n\u003cli data-section-id=\"1uwt2qc\" data-start=\"1369\" data-end=\"1410\"\u003eCompatibility: Eaton CV frame systems\u003c\/li\u003e\n\u003cli data-section-id=\"norn7l\" data-start=\"1411\" data-end=\"1465\"\u003eInstallation Use: Molded case breaker installation\u003c\/li\u003e\n\u003cli data-section-id=\"crff93\" data-start=\"1466\" data-end=\"1546\"\u003eFunction: Protects electrical systems from overload and short-circuit faults\u003c\/li\u003e\n\u003cli data-section-id=\"uehc2d\" data-start=\"1547\" data-end=\"1630\" data-is-last-node=\"\"\u003eSafety Feature: High 42 kAIC interrupting capacity for enhanced system protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"contents\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Eaton Cutler-Hammer","offers":[{"title":"NEW","offer_id":48397957890297,"sku":"CVS3200X","price":1254.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/CV3200_C_b05130c2-3a15-42a2-a07e-59a08df1b737.jpg?v=1778684634","url":"https:\/\/mycircuitbreakers.com\/products\/eaton-cvs3200x-ccv-tenant-main-breaker-200a-3-pole-42-kaic","provider":"My Circuit Breakers","version":"1.0","type":"link"}