{"product_id":"ge-teyd1035b-35-amp-1-pole-thermal-magnetic-circuit-breaker-bolt-on-480-277v-ac","title":"GE TEYD1035B 35 Amp 1 Pole Thermal Magnetic Circuit Breaker – Bolt-On – 480\/277V AC","description":"\u003cp data-start=\"110\" data-end=\"781\"\u003eThe GE TEYD1035B 35 Amp single-pole molded case circuit breaker is part of the GE TEY \/ Q-Line bolt-on series, designed for reliable lighting panel and branch circuit protection in commercial and industrial applications. It features thermal-magnetic LI (Long-Time and Instantaneous) protection to ensure safe and stable operation under overload and short-circuit conditions. The compact one-inch-per-pole design allows efficient use of panel space, while the bolt-on mounting system provides a secure electrical connection. With a high interrupting capacity of 25kA at 277V and up to 65kA at 120V systems, it is built for dependable performance in demanding environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"788\" data-end=\"810\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"811\" data-end=\"1090\"\u003e\n\u003cli data-section-id=\"42391\" data-start=\"811\" data-end=\"838\"\u003eCurrent Rating: 35 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"3ucxzo\" data-start=\"839\" data-end=\"913\"\u003eVoltage Rating: 120VAC, 240VAC, 277VAC, 480\/277VAC, 125VDC, 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1eimspx\" data-start=\"914\" data-end=\"966\"\u003eSystem Compatibility: Grounded 480Y\/277V systems\u003c\/li\u003e\n\u003cli data-section-id=\"h94jxa\" data-start=\"967\" data-end=\"1066\"\u003eInterrupting Capacity:\n\u003cul data-start=\"996\" data-end=\"1066\"\u003e\n\u003cli data-section-id=\"1x2fvkc\" data-start=\"996\" data-end=\"1016\"\u003e65 kAIC @ 120VAC\u003c\/li\u003e\n\u003cli data-section-id=\"4jmqxh\" data-start=\"1019\" data-end=\"1043\"\u003e65 kAIC @ 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"j3c79l\" data-start=\"1046\" data-end=\"1066\"\u003e25 kAIC @ 277VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1067\" data-end=\"1090\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1097\" data-end=\"1119\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1120\" data-end=\"1615\"\u003e\n\u003cli data-section-id=\"1ovneva\" data-start=\"1120\" data-end=\"1165\"\u003eBreaker Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"137pbbb\" data-start=\"1166\" data-end=\"1215\"\u003eTrip Function: LI (Long-Time \u0026amp; Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1216\" data-end=\"1253\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"10gaj13\" data-start=\"1254\" data-end=\"1281\"\u003eNumber of Poles: 1-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"s5bj2z\" data-start=\"1282\" data-end=\"1302\"\u003eFrame Type: TEYD\u003c\/li\u003e\n\u003cli data-section-id=\"erb7y6\" data-start=\"1303\" data-end=\"1330\"\u003eSeries: GE TEY \/ Q-Line\u003c\/li\u003e\n\u003cli data-section-id=\"psyc29\" data-start=\"1331\" data-end=\"1358\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"wg7m6n\" data-start=\"1359\" data-end=\"1420\"\u003eApplication: Lighting panel and branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"6b8rnh\" data-start=\"1421\" data-end=\"1523\"\u003eConstruction Features: Quick-make \/ Quick-break mechanism, common trip bar, visual trip indication\u003c\/li\u003e\n\u003cli data-section-id=\"17peyzz\" data-start=\"1524\" data-end=\"1556\"\u003eReverse Feed Capability: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1m74svd\" data-start=\"1557\" data-end=\"1615\"\u003eTrip Settings: Fixed long-time and fixed instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1622\" data-end=\"1650\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1651\" data-end=\"1875\"\u003e\n\u003cli data-section-id=\"18osvze\" data-start=\"1651\" data-end=\"1690\"\u003eContinuous Current Rating: Standard\u003c\/li\u003e\n\u003cli data-section-id=\"ja7guc\" data-start=\"1691\" data-end=\"1739\"\u003eWire Connection Type: Bolt-on lug connection\u003c\/li\u003e\n\u003cli data-section-id=\"g6yrbv\" data-start=\"1740\" data-end=\"1774\"\u003eInterrupt Rating: 25 kA @ 277V\u003c\/li\u003e\n\u003cli data-section-id=\"1v7q0dq\" data-start=\"1775\" data-end=\"1803\"\u003eTemperature Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"1l0grk8\" data-start=\"1804\" data-end=\"1875\"\u003eStandards\/Approvals: UL 489, CSA C22.2 No. 5 (TEY series compliant)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1882\" data-end=\"1898\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1899\" data-end=\"2070\"\u003e\n\u003cli data-section-id=\"1k2hqxf\" data-start=\"1899\" data-end=\"1938\"\u003eManufacturer: General Electric (GE)\u003c\/li\u003e\n\u003cli data-section-id=\"1egamqz\" data-start=\"1939\" data-end=\"1968\"\u003eCatalog Number: TEYD1035B\u003c\/li\u003e\n\u003cli data-section-id=\"19t2bj2\" data-start=\"1969\" data-end=\"1990\"\u003eUPC: 783164461503\u003c\/li\u003e\n\u003cli data-section-id=\"5yxfvo\" data-start=\"1991\" data-end=\"2025\"\u003eSeries: TEY \/ Q-Line (Bolt-On)\u003c\/li\u003e\n\u003cli data-section-id=\"gn04k1\" data-start=\"2026\" data-end=\"2070\"\u003eCategory: Lighting Panel Circuit Breaker\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48436551287033,"sku":"TEYD1035B","price":162.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000049691_400x400_6315bd57-3815-4e7e-a021-1ffe77c00aa4.jpg?v=1779560690","url":"https:\/\/mycircuitbreakers.com\/products\/ge-teyd1035b-35-amp-1-pole-thermal-magnetic-circuit-breaker-bolt-on-480-277v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}