{"product_id":"ge-teyl3040b-40-amp-3-pole-thermal-magnetic-circuit-breaker-bolt-on-480-277v-ac","title":"GE TEYL3040B 40 Amp 3 Pole Thermal Magnetic Circuit Breaker – Bolt-On – 480\/277V AC","description":"\u003cp data-start=\"110\" data-end=\"891\"\u003eThe GE TEYL3040B 40 Amp three-pole molded case circuit breaker is part of the GE TEYL high-interrupting capacity series, designed for commercial and industrial power distribution applications. It provides reliable thermal-magnetic LI (Long-Time and Instantaneous) protection for grounded 480Y\/277VAC systems. Built with a compact one-inch-per-pole design, it helps maximize panel space efficiency while maintaining high fault interruption capability. The bolt-on mounting system ensures a secure and stable installation in GE A-Series panelboards. Rated at 65kAIC at 480V, this breaker is suitable for demanding electrical environments. It also features quick-make\/quick-break mechanisms, common trip operation, and a visible trip indicator for enhanced safety and troubleshooting.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"898\" data-end=\"920\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"921\" data-end=\"1071\"\u003e\n\u003cli data-section-id=\"pw5dzr\" data-start=\"921\" data-end=\"948\"\u003eCurrent Rating: 40 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"bwprq3\" data-start=\"949\" data-end=\"980\"\u003eVoltage Rating: 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"981\" data-end=\"999\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"4agjgv\" data-start=\"1000\" data-end=\"1047\"\u003eInterrupting Capacity:\n\u003cul data-start=\"1029\" data-end=\"1047\"\u003e\n\u003cli data-section-id=\"1dp8tmp\" data-start=\"1029\" data-end=\"1047\"\u003e65 kAIC @ 480V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1048\" data-end=\"1071\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1078\" data-end=\"1100\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1101\" data-end=\"1590\"\u003e\n\u003cli data-section-id=\"1ovneva\" data-start=\"1101\" data-end=\"1146\"\u003eBreaker Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"g2iaqk\" data-start=\"1147\" data-end=\"1184\"\u003eProtection Type: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"137pbbb\" data-start=\"1185\" data-end=\"1234\"\u003eTrip Function: LI (Long-Time \u0026amp; Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"mwlhud\" data-start=\"1235\" data-end=\"1262\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"anwm5p\" data-start=\"1263\" data-end=\"1279\"\u003eSeries: TEYL\u003c\/li\u003e\n\u003cli data-section-id=\"psyc29\" data-start=\"1280\" data-end=\"1307\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1d0wym4\" data-start=\"1308\" data-end=\"1376\"\u003eApplication: Commercial and industrial branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"17bs1he\" data-start=\"1377\" data-end=\"1418\"\u003eFor Use With: GE A-Series Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1c10ihr\" data-start=\"1419\" data-end=\"1547\"\u003eConstruction Features: Quick-Make \/ Quick-Break, Common Trip Bar, Visible Trip Indication, High Interrupting Capacity Design\u003c\/li\u003e\n\u003cli data-section-id=\"bal4af\" data-start=\"1548\" data-end=\"1590\"\u003eTerminal Type: Load-side lug terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1597\" data-end=\"1625\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1626\" data-end=\"1863\"\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1626\" data-end=\"1663\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1qe8aak\" data-start=\"1664\" data-end=\"1727\"\u003eTrip Settings: Fixed long-time and instantaneous protection\u003c\/li\u003e\n\u003cli data-section-id=\"1v7q0dq\" data-start=\"1728\" data-end=\"1756\"\u003eTemperature Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"xn8nfw\" data-start=\"1757\" data-end=\"1815\"\u003eStandards\/Approvals: UL 489, CSA C22.2 No. 5, NEMA AB1\u003c\/li\u003e\n\u003cli data-section-id=\"1v542i5\" data-start=\"1816\" data-end=\"1863\"\u003eApprovals: CSA, UL, HACR (series dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1870\" data-end=\"1886\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1887\" data-end=\"1995\"\u003e\n\u003cli data-section-id=\"1k2hqxf\" data-start=\"1887\" data-end=\"1926\"\u003eManufacturer: General Electric (GE)\u003c\/li\u003e\n\u003cli data-section-id=\"1fkur9f\" data-start=\"1927\" data-end=\"1956\"\u003eCatalog Number: TEYL3040B\u003c\/li\u003e\n\u003cli data-section-id=\"1cynj96\" data-start=\"1957\" data-end=\"1978\"\u003eUPC: 783164462562\u003c\/li\u003e\n\u003cli data-section-id=\"anwm5p\" data-start=\"1979\" data-end=\"1995\"\u003eSeries: TEYL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48439617192185,"sku":"TEYL3040B","price":610.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000253057_400x400_8a8e488b-7746-4e13-a05f-86ec2a0cb17b.jpg?v=1779624367","url":"https:\/\/mycircuitbreakers.com\/products\/ge-teyl3040b-40-amp-3-pole-thermal-magnetic-circuit-breaker-bolt-on-480-277v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}