{"product_id":"ge-teyl3125b-125a-3-pole-480y-277v-bolt-on-thermal-magnetic-circuit-breaker-65kaic-480v","title":"GE TEYL3125B – 125A 3-Pole 480Y\/277V Bolt-On Thermal Magnetic Circuit Breaker – 65kAIC @ 480V","description":"\u003ch2 data-section-id=\"1bw7wp4\" data-start=\"97\" data-end=\"119\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"121\" data-end=\"578\"\u003eThe \u003cstrong data-start=\"125\" data-end=\"141\"\u003eGE TEYL3125B\u003c\/strong\u003e is a \u003cstrong data-start=\"147\" data-end=\"203\"\u003e125 Amp, 3-Pole, bolt-on molded case circuit breaker\u003c\/strong\u003e from the GE TEY Series, designed primarily for lighting panelboards and commercial distribution systems. It features a fixed thermal magnetic trip unit that provides dependable overload and short-circuit protection while allowing quick installation in compatible GE panelboards. The compact 1-inch-per-pole design makes it ideal for high-density lighting panel applications.\u003c\/p\u003e\n\u003chr data-start=\"580\" data-end=\"583\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"585\" data-end=\"600\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"602\" data-end=\"948\"\u003e\n\u003cli data-section-id=\"d6iqu3\" data-start=\"602\" data-end=\"648\"\u003eGenuine GE \/ ABB TEYL Series Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"2f2zs8\" data-start=\"649\" data-end=\"676\"\u003e125 Amp Continuous Rating\u003c\/li\u003e\n\u003cli data-section-id=\"tj11kg\" data-start=\"677\" data-end=\"699\"\u003e3-Pole Configuration\u003c\/li\u003e\n\u003cli data-section-id=\"btj058\" data-start=\"700\" data-end=\"718\"\u003eBolt-On Mounting\u003c\/li\u003e\n\u003cli data-section-id=\"j1zwtg\" data-start=\"719\" data-end=\"747\"\u003eThermal Magnetic Trip Unit\u003c\/li\u003e\n\u003cli data-section-id=\"evup05\" data-start=\"748\" data-end=\"797\"\u003eFixed Long-Time \u0026amp; Instantaneous Protection (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"qj4srd\" data-start=\"798\" data-end=\"832\"\u003eCompact 1\" Width Per Pole Design\u003c\/li\u003e\n\u003cli data-section-id=\"j4urs3\" data-start=\"833\" data-end=\"868\"\u003eSuitable for Lighting Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"gcayzg\" data-start=\"869\" data-end=\"915\"\u003eQuick-Make \/ Quick-Break Operating Mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1e19l7s\" data-start=\"916\" data-end=\"936\"\u003eCommon Trip Design\u003c\/li\u003e\n\u003cli data-section-id=\"1qadegi\" data-start=\"937\" data-end=\"948\"\u003eUL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"950\" data-end=\"953\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"955\" data-end=\"982\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp data-start=\"984\" data-end=\"1025\"\u003eManufacturer: General Electric (GE) \/ ABB\u003c\/p\u003e\n\u003cp data-start=\"1027\" data-end=\"1056\"\u003eCatalog Number: \u003cstrong data-start=\"1043\" data-end=\"1056\"\u003eTEYL3125B\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1058\" data-end=\"1083\"\u003eSeries: TEYL (TEY Series)\u003c\/p\u003e\n\u003cp data-start=\"1085\" data-end=\"1126\"\u003eProduct Type: Molded Case Circuit Breaker\u003c\/p\u003e\n\u003cp data-start=\"1128\" data-end=\"1151\"\u003eMounting Style: Bolt-On\u003c\/p\u003e\n\u003cp data-start=\"1153\" data-end=\"1161\"\u003ePoles: 3\u003c\/p\u003e\n\u003cp data-start=\"1163\" data-end=\"1177\"\u003eAmperage: 125A\u003c\/p\u003e\n\u003cp data-start=\"1179\" data-end=\"1194\"\u003eVoltage Rating:\u003c\/p\u003e\n\u003cul data-start=\"1195\" data-end=\"1248\"\u003e\n\u003cli data-section-id=\"1wtneja\" data-start=\"1195\" data-end=\"1207\"\u003e120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"flrcq2\" data-start=\"1208\" data-end=\"1216\"\u003e240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"gbiv8k\" data-start=\"1217\" data-end=\"1230\"\u003e480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"do0573\" data-start=\"1231\" data-end=\"1239\"\u003e125VDC\u003c\/li\u003e\n\u003cli data-section-id=\"fnu2mm\" data-start=\"1240\" data-end=\"1248\"\u003e250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1250\" data-end=\"1271\"\u003eInterrupting Ratings:\u003c\/p\u003e\n\u003cul data-start=\"1272\" data-end=\"1372\"\u003e\n\u003cli data-section-id=\"1qv6hz\" data-start=\"1272\" data-end=\"1294\"\u003e100kAIC @ 120\/240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"nt3m8r\" data-start=\"1295\" data-end=\"1313\"\u003e100kAIC @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"19v45hj\" data-start=\"1314\" data-end=\"1336\"\u003e65kAIC @ 480Y\/277VAC\u003c\/li\u003e\n\u003cli data-section-id=\"bw8hk9\" data-start=\"1337\" data-end=\"1354\"\u003e42kAIC @ 125VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1qkst1k\" data-start=\"1355\" data-end=\"1372\"\u003e35kAIC @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1374\" data-end=\"1401\"\u003eTrip Unit: Thermal Magnetic\u003c\/p\u003e\n\u003cp data-start=\"1403\" data-end=\"1418\"\u003eTrip Functions:\u003c\/p\u003e\n\u003cul data-start=\"1419\" data-end=\"1462\"\u003e\n\u003cli data-section-id=\"gxs7f1\" data-start=\"1419\" data-end=\"1438\"\u003eLong-Time (Fixed)\u003c\/li\u003e\n\u003cli data-section-id=\"10oomw7\" data-start=\"1439\" data-end=\"1462\"\u003eInstantaneous (Fixed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1464\" data-end=\"1490\"\u003eConnection Type: Load Lugs\u003c\/p\u003e\n\u003cp data-start=\"1492\" data-end=\"1503\"\u003eWire Range:\u003c\/p\u003e\n\u003cul data-start=\"1504\" data-end=\"1542\"\u003e\n\u003cli data-section-id=\"adhakl\" data-start=\"1504\" data-end=\"1542\"\u003e#4 AWG to 2\/0 AWG Copper or Aluminum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1544\" data-end=\"1554\"\u003eFrequency:\u003c\/p\u003e\n\u003cul data-start=\"1555\" data-end=\"1565\"\u003e\n\u003cli data-section-id=\"ot6e3a\" data-start=\"1555\" data-end=\"1565\"\u003e50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1567\" data-end=\"1573\"\u003ePhase:\u003c\/p\u003e\n\u003cul data-start=\"1574\" data-end=\"1583\"\u003e\n\u003cli data-section-id=\"6prxck\" data-start=\"1574\" data-end=\"1583\"\u003e3 Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1585\" data-end=\"1607\"\u003eOperating Temperature:\u003c\/p\u003e\n\u003cul data-start=\"1608\" data-end=\"1614\"\u003e\n\u003cli data-section-id=\"1j2dhi7\" data-start=\"1608\" data-end=\"1614\"\u003e40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1616\" data-end=\"1635\"\u003eApproximate Weight:\u003c\/p\u003e\n\u003cul data-start=\"1636\" data-end=\"1645\"\u003e\n\u003cli data-section-id=\"l1x2op\" data-start=\"1636\" data-end=\"1645\"\u003e2.0 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1647\" data-end=\"1675\"\u003eUPC \/ GTIN:\u003cbr\u003e\u003cstrong data-start=\"1659\" data-end=\"1675\"\u003e783164462654\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"1677\" data-end=\"1680\"\u003e\n\u003ch2 data-section-id=\"nukan1\" data-start=\"1682\" data-end=\"1704\"\u003ePanel Compatibility\u003c\/h2\u003e\n\u003cp data-start=\"1706\" data-end=\"1770\"\u003eCompatible with GE \/ ABB bolt-on lighting panelboards including:\u003c\/p\u003e\n\u003cul data-start=\"1772\" data-end=\"1876\"\u003e\n\u003cli data-section-id=\"xgz5cx\" data-start=\"1772\" data-end=\"1792\"\u003eAS Lighting Panels\u003c\/li\u003e\n\u003cli data-section-id=\"1nfu8v6\" data-start=\"1793\" data-end=\"1819\"\u003eTEY \/ Q-Line Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1s50i37\" data-start=\"1820\" data-end=\"1876\"\u003eOther GE panelboards designed for TEY bolt-on breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1878\" data-end=\"1964\"\u003eAlways verify panel labeling and interrupting rating requirements before installation.\u003c\/p\u003e\n\u003chr data-start=\"1966\" data-end=\"1969\"\u003e\n\u003ch2 data-section-id=\"r67mh1\" data-start=\"1971\" data-end=\"1992\"\u003eInterchangeability\u003c\/h2\u003e\n\u003cp data-start=\"1994\" data-end=\"2200\"\u003eThe \u003cstrong data-start=\"1998\" data-end=\"2011\"\u003eTEYL3125B\u003c\/strong\u003e is the \u003cstrong data-start=\"2019\" data-end=\"2029\"\u003e65kAIC\u003c\/strong\u003e version of the TEY family and is \u003cstrong data-start=\"2063\" data-end=\"2095\"\u003enot directly interchangeable\u003c\/strong\u003e with lower interrupting rating models unless the available fault current at the installation permits it.\u003c\/p\u003e\n\u003cp data-start=\"2202\" data-end=\"2225\"\u003eRelated models include:\u003c\/p\u003e\n\u003cul data-start=\"2227\" data-end=\"2302\"\u003e\n\u003cli data-section-id=\"w8pqgn\" data-start=\"2227\" data-end=\"2247\"\u003eTEYD3125B – 25kAIC\u003c\/li\u003e\n\u003cli data-section-id=\"1ged5i2\" data-start=\"2248\" data-end=\"2268\"\u003eTEYH3125B – 35kAIC\u003c\/li\u003e\n\u003cli data-section-id=\"w3mjoz\" data-start=\"2269\" data-end=\"2302\"\u003eTEYL3125B – 65kAIC (this model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2304\" data-end=\"2429\"\u003eAlways replace with a breaker having an equal or higher interrupting rating that matches the panel's listing and application.\u003c\/p\u003e\n\u003chr data-start=\"2431\" data-end=\"2434\"\u003e\n\u003ch2 data-section-id=\"we2dfi\" data-start=\"2436\" data-end=\"2451\"\u003eProduct Data\u003c\/h2\u003e\n\u003cp data-start=\"2453\" data-end=\"2468\"\u003eBrand: GE \/ ABB\u003c\/p\u003e\n\u003cp data-start=\"2470\" data-end=\"2509\"\u003eManufacturer Part Number: \u003cstrong data-start=\"2496\" data-end=\"2509\"\u003eTEYL3125B\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2511\" data-end=\"2576\"\u003eCondition: \u003cem data-start=\"2522\" data-end=\"2576\"\u003e(New, Used, or Reconditioned – select as applicable)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-start=\"2578\" data-end=\"2619\"\u003eProduct Type: Molded Case Circuit Breaker\u003c\/p\u003e\n\u003cp data-start=\"2621\" data-end=\"2632\"\u003eFrame: TEYL\u003c\/p\u003e\n\u003cp data-start=\"2634\" data-end=\"2651\"\u003eMounting: Bolt-On\u003c\/p\u003e\n\u003cp data-start=\"2653\" data-end=\"2661\"\u003ePoles: 3\u003c\/p\u003e\n\u003cp data-start=\"2663\" data-end=\"2677\"\u003eAmperage: 125A\u003c\/p\u003e\n\u003cp data-start=\"2679\" data-end=\"2699\"\u003eVoltage: 480Y\/277VAC\u003c\/p\u003e\n\u003cp data-start=\"2701\" data-end=\"2728\"\u003eTrip Type: Thermal Magnetic\u003c\/p\u003e\n\u003cp data-start=\"2730\" data-end=\"2768\"\u003eInterrupt Rating: 65kAIC @ 480Y\/277VAC\u003c\/p\u003e\n\u003cp data-start=\"2770\" data-end=\"2791\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eUPC: \u003cstrong data-start=\"2775\" data-end=\"2791\" data-is-last-node=\"\"\u003e783164462654\u003c\/strong\u003e\u003c\/p\u003e","brand":"My Circuit Breakers","offers":[{"title":"New","offer_id":48722903793913,"sku":null,"price":1395.99,"currency_code":"USD","in_stock":true},{"title":"Reconditioned","offer_id":48722903826681,"sku":null,"price":1099.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000253117_400x400_53b68d26-2043-456d-8d63-e67030ea8ad1.jpg?v=1785192708","url":"https:\/\/mycircuitbreakers.com\/products\/ge-teyl3125b-125a-3-pole-480y-277v-bolt-on-thermal-magnetic-circuit-breaker-65kaic-480v","provider":"My Circuit Breakers","version":"1.0","type":"link"}