{"product_id":"general-electric-teb122060-60a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-240vac","title":"General Electric TEB122060 60A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On – 240VAC","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-6a0f3d4f-7134-83ec-ae9a-05f0895f2050-24\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a0f3d4f-7134-83ec-ae9a-05f0895f2050-24\" data-turn-id-container=\"request-6a0f3d4f-7134-83ec-ae9a-05f0895f2050-24\" data-testid=\"conversation-turn-86\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"4fb33a31-c519-48c7-9a92-bb4a4f048876\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"119\" data-end=\"641\"\u003eThe General Electric TEB122060 is an E150 Series molded case circuit breaker designed for reliable overcurrent protection in commercial and industrial electrical systems. Rated at 60 Amps with a 2-pole configuration, this bolt-on breaker is engineered for installation in GE panelboards, switchboards, and motor control centers. It delivers dependable protection for branch circuits operating at 240VAC, making it suitable for a wide range of general-purpose electrical distribution applications.\u003c\/p\u003e\n\u003cp data-start=\"648\" data-end=\"670\"\u003e\u003cstrong data-start=\"648\" data-end=\"670\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"672\" data-end=\"768\"\u003e\n\u003cli data-section-id=\"1j3vgnm\" data-start=\"672\" data-end=\"699\"\u003eCurrent Rating: 60 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"124hxn6\" data-start=\"700\" data-end=\"726\"\u003eVoltage Rating: 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"11l1v4m\" data-start=\"727\" data-end=\"768\"\u003eInterrupting Rating: 10 kAIC @ 240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"775\" data-end=\"797\"\u003e\u003cstrong data-start=\"775\" data-end=\"797\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"799\" data-end=\"1129\"\u003e\n\u003cli data-section-id=\"1bghv1t\" data-start=\"799\" data-end=\"828\"\u003eCatalog Number: TEB122060\u003c\/li\u003e\n\u003cli data-section-id=\"1fufhq3\" data-start=\"829\" data-end=\"856\"\u003eBrand: General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1jvp0o\" data-start=\"857\" data-end=\"907\"\u003eProduct Type: Thermal Magnetic Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"14cszkx\" data-start=\"908\" data-end=\"930\"\u003eProduct Line: E150\u003c\/li\u003e\n\u003cli data-section-id=\"sco8td\" data-start=\"931\" data-end=\"951\"\u003eFrame Type: E150\u003c\/li\u003e\n\u003cli data-section-id=\"kjxaur\" data-start=\"952\" data-end=\"979\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"980\" data-end=\"1007\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1b3baop\" data-start=\"1008\" data-end=\"1045\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"10mcaq2\" data-start=\"1046\" data-end=\"1094\"\u003eTrip Function: LI (Long-Time, Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"rhuepe\" data-start=\"1095\" data-end=\"1129\"\u003eSuitable for Reverse Feed: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1136\" data-end=\"1159\"\u003e\u003cstrong data-start=\"1136\" data-end=\"1159\"\u003eProtection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1161\" data-end=\"1303\"\u003e\n\u003cli data-section-id=\"1bimvwv\" data-start=\"1161\" data-end=\"1198\"\u003eFixed Thermal Magnetic Protection\u003c\/li\u003e\n\u003cli data-section-id=\"k9wztg\" data-start=\"1199\" data-end=\"1252\"\u003eReliable Overcurrent and Short-Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1c0fwpe\" data-start=\"1253\" data-end=\"1276\"\u003eTrip-Free Mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1om3hzd\" data-start=\"1277\" data-end=\"1303\"\u003eHACR Rated Performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1310\" data-end=\"1333\"\u003e\u003cstrong data-start=\"1310\" data-end=\"1333\"\u003eConnection \u0026amp; Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1335\" data-end=\"1477\"\u003e\n\u003cli data-section-id=\"13wcb6m\" data-start=\"1335\" data-end=\"1417\"\u003eLine and Load Lugs Included (typical WL suffix configuration where applicable)\u003c\/li\u003e\n\u003cli data-section-id=\"1ho4y56\" data-start=\"1418\" data-end=\"1477\"\u003eTemperature Rating: 60\/75°C up to 100A, 75°C above 100A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1484\" data-end=\"1506\"\u003e\u003cstrong data-start=\"1484\" data-end=\"1506\"\u003eTechnical Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1508\" data-end=\"1661\"\u003e\n\u003cli data-section-id=\"1o4ikzw\" data-start=\"1508\" data-end=\"1540\"\u003eCompact bolt-on construction\u003c\/li\u003e\n\u003cli data-section-id=\"woib6n\" data-start=\"1541\" data-end=\"1586\"\u003eDesigned for GE E150 system compatibility\u003c\/li\u003e\n\u003cli data-section-id=\"pgsmi0\" data-start=\"1587\" data-end=\"1625\"\u003eQuick-make \/ quick-break operation\u003c\/li\u003e\n\u003cli data-section-id=\"p49nm0\" data-start=\"1626\" data-end=\"1661\"\u003eNon-interchangeable trip design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1668\" data-end=\"1698\"\u003e\u003cstrong data-start=\"1668\" data-end=\"1698\"\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1700\" data-end=\"1760\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"1700\" data-end=\"1713\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1ygh62h\" data-start=\"1714\" data-end=\"1731\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1eaolqv\" data-start=\"1732\" data-end=\"1745\"\u003eNEMA AB-1\u003c\/li\u003e\n\u003cli data-section-id=\"mq9pch\" data-start=\"1746\" data-end=\"1760\"\u003eHACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1767\" data-end=\"1783\"\u003e\u003cstrong data-start=\"1767\" data-end=\"1783\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1785\" data-end=\"1942\"\u003e\n\u003cli data-section-id=\"ht88x8\" data-start=\"1785\" data-end=\"1811\"\u003eCommercial panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"gi2g6r\" data-start=\"1812\" data-end=\"1839\"\u003eIndustrial switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"18xv2zo\" data-start=\"1840\" data-end=\"1872\"\u003eMotor control centers (MCCs)\u003c\/li\u003e\n\u003cli data-section-id=\"8t3cj6\" data-start=\"1873\" data-end=\"1904\"\u003eHVAC and equipment circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1qh4w3h\" data-start=\"1905\" data-end=\"1942\"\u003eGeneral branch circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48433835737337,"sku":"TEB122060","price":333.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000049670_400x400_6e9a6df2-3599-4be9-b511-c227d54c8ac0.jpg?v=1779535447","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-teb122060-60a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-240vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}