{"product_id":"general-electric-tec36050-50a-3-pole-motor-circuit-protector-unit-mount-600vac","title":"General Electric TEC36050 50A 3-Pole Motor Circuit Protector – Unit Mount – 600VAC","description":"\u003cp data-start=\"112\" data-end=\"739\"\u003eThe General Electric TEC36050 is a legacy E-Frame motor circuit protector (MCP) designed for use in motor control and industrial power distribution systems. Rated at 50 Amps with a 3-pole configuration, this unit-mount device provides instantaneous-only magnetic protection and is intended to operate with external overload relays. It is compatible with GE A-Series and Spectra Series panelboards, combination starters, and motor control centers. Built for reliability in motor protection applications, it delivers adjustable magnetic trip performance to reduce nuisance tripping during motor startup.\u003c\/p\u003e\n\u003cp data-start=\"746\" data-end=\"768\"\u003e\u003cstrong data-start=\"746\" data-end=\"768\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"770\" data-end=\"936\"\u003e\n\u003cli data-section-id=\"ad7dht\" data-start=\"770\" data-end=\"797\"\u003eCurrent Rating: 50 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1r8arug\" data-start=\"798\" data-end=\"842\"\u003eVoltage Rating: 240VAC \/ 480VAC \/ 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1h0yue4\" data-start=\"843\" data-end=\"936\"\u003eInterrupting Rating:\n\u003cul data-start=\"870\" data-end=\"936\"\u003e\n\u003cli data-section-id=\"1waf7sc\" data-start=\"870\" data-end=\"890\"\u003e10 kAIC @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1v9yhk6\" data-start=\"893\" data-end=\"913\"\u003e10 kAIC @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"xknauk\" data-start=\"916\" data-end=\"936\"\u003e10 kAIC @ 600VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"943\" data-end=\"965\"\u003e\u003cstrong data-start=\"943\" data-end=\"965\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"967\" data-end=\"1326\"\u003e\n\u003cli data-section-id=\"l0uw9z\" data-start=\"967\" data-end=\"995\"\u003eCatalog Number: TEC36050\u003c\/li\u003e\n\u003cli data-section-id=\"1p9tho6\" data-start=\"996\" data-end=\"1034\"\u003eBrand: General Electric (ABB \/ GE)\u003c\/li\u003e\n\u003cli data-section-id=\"av02e4\" data-start=\"1035\" data-end=\"1050\"\u003eSeries: TEC\u003c\/li\u003e\n\u003cli data-section-id=\"sfx8s7\" data-start=\"1051\" data-end=\"1098\"\u003eProduct Type: Motor Circuit Protector (MCP)\u003c\/li\u003e\n\u003cli data-section-id=\"g2auwh\" data-start=\"1099\" data-end=\"1131\"\u003eFrame Type: E-Frame (Legacy)\u003c\/li\u003e\n\u003cli data-section-id=\"bad5e\" data-start=\"1132\" data-end=\"1159\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"13hyuq3\" data-start=\"1160\" data-end=\"1178\"\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"pl9r6s\" data-start=\"1179\" data-end=\"1209\"\u003eMounting Style: Unit Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1ly7lqe\" data-start=\"1210\" data-end=\"1244\"\u003eTrip Technology: Magnetic Only\u003c\/li\u003e\n\u003cli data-section-id=\"90dig4\" data-start=\"1245\" data-end=\"1282\"\u003eTrip Function: Instantaneous Only\u003c\/li\u003e\n\u003cli data-section-id=\"117r7h8\" data-start=\"1283\" data-end=\"1326\"\u003eTrip Adjustability: Adjustable Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1333\" data-end=\"1356\"\u003e\u003cstrong data-start=\"1333\" data-end=\"1356\"\u003eProtection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1358\" data-end=\"1582\"\u003e\n\u003cli data-section-id=\"1jp5zt2\" data-start=\"1358\" data-end=\"1397\"\u003eInstantaneous-only motor protection\u003c\/li\u003e\n\u003cli data-section-id=\"1v0yvtv\" data-start=\"1398\" data-end=\"1448\"\u003eDesigned for use with external overload relays\u003c\/li\u003e\n\u003cli data-section-id=\"1mw2hxg\" data-start=\"1449\" data-end=\"1521\"\u003eAdjustable magnetic trip (prevents nuisance tripping during startup)\u003c\/li\u003e\n\u003cli data-section-id=\"p49nm0\" data-start=\"1522\" data-end=\"1557\"\u003eNon-interchangeable trip design\u003c\/li\u003e\n\u003cli data-section-id=\"10fzyt1\" data-start=\"1558\" data-end=\"1582\"\u003eReverse feed capable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1589\" data-end=\"1612\"\u003e\u003cstrong data-start=\"1589\" data-end=\"1612\"\u003eConnection \u0026amp; Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1614\" data-end=\"1723\"\u003e\n\u003cli data-section-id=\"1nbdjus\" data-start=\"1614\" data-end=\"1637\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"4n1l2o\" data-start=\"1638\" data-end=\"1682\"\u003eWire Range: 14–3 AWG (Cu), 12–1 AWG (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"11hneqy\" data-start=\"1683\" data-end=\"1702\"\u003eMax Wire: 3 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1frkg9u\" data-start=\"1703\" data-end=\"1723\"\u003eMin Wire: 14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1730\" data-end=\"1752\"\u003e\u003cstrong data-start=\"1730\" data-end=\"1752\"\u003eTechnical Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1754\" data-end=\"1921\"\u003e\n\u003cli data-section-id=\"isc9d8\" data-start=\"1754\" data-end=\"1794\"\u003eMotor circuit protector (MCP) design\u003c\/li\u003e\n\u003cli data-section-id=\"1cd5b5c\" data-start=\"1795\" data-end=\"1819\"\u003eMag-break technology\u003c\/li\u003e\n\u003cli data-section-id=\"6s33lz\" data-start=\"1820\" data-end=\"1858\"\u003eHeavy-duty industrial construction\u003c\/li\u003e\n\u003cli data-section-id=\"c9jiax\" data-start=\"1859\" data-end=\"1921\"\u003eCompatible with combination motor starters and panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1928\" data-end=\"1958\"\u003e\u003cstrong data-start=\"1928\" data-end=\"1958\"\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1960\" data-end=\"2060\"\u003e\n\u003cli data-section-id=\"j8lt5v\" data-start=\"1960\" data-end=\"1970\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"139c2as\" data-start=\"1971\" data-end=\"1992\"\u003eCSA C22.2 No. 5.1\u003c\/li\u003e\n\u003cli data-section-id=\"3h4a0l\" data-start=\"1993\" data-end=\"2009\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"3l3yo\" data-start=\"2010\" data-end=\"2032\"\u003eUL Recognized (UR)\u003c\/li\u003e\n\u003cli data-section-id=\"1sab303\" data-start=\"2033\" data-end=\"2060\"\u003e40°C temperature rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2067\" data-end=\"2083\"\u003e\u003cstrong data-start=\"2067\" data-end=\"2083\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2085\" data-end=\"2250\"\u003e\n\u003cli data-section-id=\"18xv2zo\" data-start=\"2085\" data-end=\"2117\"\u003eMotor control centers (MCCs)\u003c\/li\u003e\n\u003cli data-section-id=\"17lt6gp\" data-start=\"2118\" data-end=\"2148\"\u003eCombination motor starters\u003c\/li\u003e\n\u003cli data-section-id=\"egip0l\" data-start=\"2149\" data-end=\"2176\"\u003eGE A-Series panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"cd2qej\" data-start=\"2177\" data-end=\"2210\"\u003eGE Spectra Series panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"f97piu\" data-start=\"2211\" data-end=\"2250\"\u003eIndustrial motor protection systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48433981423865,"sku":"TEC36050","price":2854.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/tec36050_1_1024x_c65be8da-c8b4-4c3a-87e3-c4497ee28994.jpg?v=1779535901","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-tec36050-50a-3-pole-motor-circuit-protector-unit-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}