{"product_id":"general-electric-ted113030-30a-1-pole-thermal-magnetic-circuit-breaker-e-frame-277-480vac","title":"General Electric TED113030 30A 1-Pole Thermal Magnetic Circuit Breaker – E-Frame – 277\/480VAC","description":"\u003cp data-start=\"123\" data-end=\"663\"\u003eThe General Electric TED113030 is an E-Frame series thermal magnetic circuit breaker designed for dependable overcurrent protection in commercial and industrial electrical systems. Rated at 30 Amps with a 1-pole configuration, this breaker is suitable for 277\/480VAC applications and provides reliable protection for branch circuits and equipment loads. Built for integration into GE panelboards, switchboards, and power distribution systems, it ensures consistent performance in demanding electrical environments.\u003c\/p\u003e\n\u003cp data-start=\"670\" data-end=\"692\"\u003e\u003cstrong data-start=\"670\" data-end=\"692\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"694\" data-end=\"785\"\u003e\n\u003cli data-section-id=\"15kyntj\" data-start=\"694\" data-end=\"721\"\u003eCurrent Rating: 30 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1k6eckl\" data-start=\"722\" data-end=\"752\"\u003eVoltage Rating: 277\/480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"i4nhw0\" data-start=\"753\" data-end=\"785\"\u003eInterrupting Rating: 14 kAIC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"792\" data-end=\"814\"\u003e\u003cstrong data-start=\"792\" data-end=\"814\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"816\" data-end=\"1164\"\u003e\n\u003cli data-section-id=\"19x1t68\" data-start=\"816\" data-end=\"845\"\u003eCatalog Number: TED113030\u003c\/li\u003e\n\u003cli data-section-id=\"1fufhq3\" data-start=\"846\" data-end=\"873\"\u003eBrand: General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1jvp0o\" data-start=\"874\" data-end=\"924\"\u003eProduct Type: Thermal Magnetic Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1oo3d2z\" data-start=\"925\" data-end=\"957\"\u003eProduct Line: E150 \/ E-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"bpyoo5\" data-start=\"958\" data-end=\"981\"\u003eFrame Type: E-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1qtmh1s\" data-start=\"982\" data-end=\"1009\"\u003eNumber of Poles: 1-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"g9dag2\" data-start=\"1010\" data-end=\"1077\"\u003eMounting Style: Bolt-On \/ Unit Mount (E-Frame system dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"1b3baop\" data-start=\"1078\" data-end=\"1115\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"10mcaq2\" data-start=\"1116\" data-end=\"1164\"\u003eTrip Function: LI (Long-Time, Instantaneous)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1171\" data-end=\"1194\"\u003e\u003cstrong data-start=\"1171\" data-end=\"1194\"\u003eProtection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1196\" data-end=\"1356\"\u003e\n\u003cli data-section-id=\"1zopf3\" data-start=\"1196\" data-end=\"1233\"\u003eFixed thermal magnetic protection\u003c\/li\u003e\n\u003cli data-section-id=\"1b087q3\" data-start=\"1234\" data-end=\"1284\"\u003eReliable short-circuit and overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"61jjm3\" data-start=\"1285\" data-end=\"1325\"\u003eSuitable for AC distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1c7j0rf\" data-start=\"1326\" data-end=\"1356\"\u003eCompact single-pole design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1363\" data-end=\"1386\"\u003e\u003cstrong data-start=\"1363\" data-end=\"1386\"\u003eConnection \u0026amp; Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1388\" data-end=\"1489\"\u003e\n\u003cli data-section-id=\"rgf8x8\" data-start=\"1388\" data-end=\"1444\"\u003eTerminal Type: Lugs (varies by configuration\/suffix)\u003c\/li\u003e\n\u003cli data-section-id=\"1q8f9f2\" data-start=\"1445\" data-end=\"1489\"\u003eCu\/Al compatible where WL suffix applies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1496\" data-end=\"1518\"\u003e\u003cstrong data-start=\"1496\" data-end=\"1518\"\u003eTechnical Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1520\" data-end=\"1668\"\u003e\n\u003cli data-section-id=\"37l920\" data-start=\"1520\" data-end=\"1556\"\u003eE-Frame molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"1e4usb9\" data-start=\"1557\" data-end=\"1597\"\u003eDesigned for reverse feed capability\u003c\/li\u003e\n\u003cli data-section-id=\"65p2ld\" data-start=\"1598\" data-end=\"1636\"\u003eNon-interchangeable trip mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1afmk7l\" data-start=\"1637\" data-end=\"1668\"\u003eIndustrial-grade durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1675\" data-end=\"1705\"\u003e\u003cstrong data-start=\"1675\" data-end=\"1705\"\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1707\" data-end=\"1792\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"1707\" data-end=\"1720\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1ygh62h\" data-start=\"1721\" data-end=\"1738\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"189css3\" data-start=\"1739\" data-end=\"1792\"\u003eSuitable for service equipment (where applicable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1799\" data-end=\"1815\"\u003e\u003cstrong data-start=\"1799\" data-end=\"1815\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1817\" data-end=\"1990\"\u003e\n\u003cli data-section-id=\"1wuqvu5\" data-start=\"1817\" data-end=\"1849\"\u003eCommercial lighting circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1uq9ll\" data-start=\"1850\" data-end=\"1880\"\u003eIndustrial control systems\u003c\/li\u003e\n\u003cli data-section-id=\"10zvvcw\" data-start=\"1881\" data-end=\"1913\"\u003ePanelboards and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"11p2iih\" data-start=\"1914\" data-end=\"1952\"\u003e277V lighting distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1qh4w3h\" data-start=\"1953\" data-end=\"1990\"\u003eGeneral branch circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48434092736761,"sku":"TED113030","price":201.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000049670_400x400_1b857b87-4a64-4992-9e1e-9c571338599c.jpg?v=1779536201","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-ted113030-30a-1-pole-thermal-magnetic-circuit-breaker-e-frame-277-480vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}