{"product_id":"general-electric-ted113045-45a-3-pole-thermal-magnetic-circuit-breaker-e-frame-600vac","title":"General Electric TED113045 45A 1-Pole Thermal Magnetic Circuit Breaker – E-Frame – 600VAC","description":"\u003cp data-start=\"119\" data-end=\"619\"\u003eThe General Electric TED113045 is an E-Frame series thermal magnetic circuit breaker designed for reliable overcurrent protection in commercial and industrial electrical distribution systems. Rated at 45 Amps with a 3-pole configuration, this breaker is suitable for three-phase applications up to 600VAC. It is designed for use in GE panelboards, switchboards, and motor control centers, providing dependable protection for general-purpose electrical distribution circuits.\u003c\/p\u003e\n\u003cp data-start=\"626\" data-end=\"648\"\u003e\u003cstrong data-start=\"626\" data-end=\"648\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"650\" data-end=\"784\"\u003e\n\u003cli data-section-id=\"fsvd2t\" data-start=\"650\" data-end=\"677\"\u003eCurrent Rating: 45 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1t5slu\" data-start=\"678\" data-end=\"704\"\u003eVoltage Rating: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"3liduw\" data-start=\"705\" data-end=\"784\"\u003eInterrupting Rating: Based on E-Frame system rating (application dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"791\" data-end=\"813\"\u003e\u003cstrong data-start=\"791\" data-end=\"813\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"815\" data-end=\"1155\"\u003e\n\u003cli data-section-id=\"19x5mvm\" data-start=\"815\" data-end=\"844\"\u003eCatalog Number: TED113045\u003c\/li\u003e\n\u003cli data-section-id=\"1fufhq3\" data-start=\"845\" data-end=\"872\"\u003eBrand: General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1jvp0o\" data-start=\"873\" data-end=\"923\"\u003eProduct Type: Thermal Magnetic Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1oo3d2z\" data-start=\"924\" data-end=\"956\"\u003eProduct Line: E150 \/ E-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"bpyoo5\" data-start=\"957\" data-end=\"980\"\u003eFrame Type: E-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"bad5e\" data-start=\"981\" data-end=\"1008\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"16901tj\" data-start=\"1009\" data-end=\"1068\"\u003eMounting Style: Bolt-On \/ Unit Mount (system dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"1b3baop\" data-start=\"1069\" data-end=\"1106\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"10mcaq2\" data-start=\"1107\" data-end=\"1155\"\u003eTrip Function: LI (Long-Time, Instantaneous)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1162\" data-end=\"1185\"\u003e\u003cstrong data-start=\"1162\" data-end=\"1185\"\u003eProtection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1187\" data-end=\"1359\"\u003e\n\u003cli data-section-id=\"q3d2xq\" data-start=\"1187\" data-end=\"1230\"\u003eThermal Magnetic overcurrent protection\u003c\/li\u003e\n\u003cli data-section-id=\"ehfw08\" data-start=\"1231\" data-end=\"1261\"\u003eFixed trip characteristics\u003c\/li\u003e\n\u003cli data-section-id=\"1b087q3\" data-start=\"1262\" data-end=\"1312\"\u003eReliable short-circuit and overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"swf29i\" data-start=\"1313\" data-end=\"1359\"\u003eDesigned for AC power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1366\" data-end=\"1389\"\u003e\u003cstrong data-start=\"1366\" data-end=\"1389\"\u003eConnection \u0026amp; Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1391\" data-end=\"1492\"\u003e\n\u003cli data-section-id=\"rgf8x8\" data-start=\"1391\" data-end=\"1447\"\u003eTerminal Type: Lugs (varies by configuration\/suffix)\u003c\/li\u003e\n\u003cli data-section-id=\"1q8f9f2\" data-start=\"1448\" data-end=\"1492\"\u003eCu\/Al compatible where WL suffix applies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1499\" data-end=\"1521\"\u003e\u003cstrong data-start=\"1499\" data-end=\"1521\"\u003eTechnical Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1523\" data-end=\"1697\"\u003e\n\u003cli data-section-id=\"7nb3sa\" data-start=\"1523\" data-end=\"1570\"\u003eHeavy-duty E-Frame molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"19fqhv2\" data-start=\"1571\" data-end=\"1613\"\u003eSuitable for reverse feed applications\u003c\/li\u003e\n\u003cli data-section-id=\"p49nm0\" data-start=\"1614\" data-end=\"1649\"\u003eNon-interchangeable trip design\u003c\/li\u003e\n\u003cli data-section-id=\"10szqn6\" data-start=\"1650\" data-end=\"1697\"\u003eIndustrial-grade durability and performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1704\" data-end=\"1734\"\u003e\u003cstrong data-start=\"1704\" data-end=\"1734\"\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1736\" data-end=\"1821\"\u003e\n\u003cli data-section-id=\"11a7gqd\" data-start=\"1736\" data-end=\"1749\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1ygh62h\" data-start=\"1750\" data-end=\"1767\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"189css3\" data-start=\"1768\" data-end=\"1821\"\u003eSuitable for service equipment (where applicable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1828\" data-end=\"1844\"\u003e\u003cstrong data-start=\"1828\" data-end=\"1844\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1846\" data-end=\"2049\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"1846\" data-end=\"1892\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"4ynpmv\" data-start=\"1893\" data-end=\"1936\"\u003eIndustrial switchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"18xv2zo\" data-start=\"1937\" data-end=\"1969\"\u003eMotor control centers (MCCs)\u003c\/li\u003e\n\u003cli data-section-id=\"146g0rr\" data-start=\"1970\" data-end=\"2011\"\u003eThree-phase branch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1y4v571\" data-start=\"2012\" data-end=\"2049\"\u003eHVAC and equipment power circuits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48434217156857,"sku":"TED113045","price":201.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/9PAA00000049670_400x400_03a4e3d3-6c30-4143-9615-9dfbc1c82109.jpg?v=1779536552","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-ted113045-45a-3-pole-thermal-magnetic-circuit-breaker-e-frame-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}