{"product_id":"general-electric-ted124045-45a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-480vac","title":"General Electric TED124045 45A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On – 480VAC","description":"\u003cp data-start=\"119\" data-end=\"614\"\u003eThe General Electric TED124045 is a legacy E-Frame thermal magnetic molded case circuit breaker designed for reliable overcurrent and short-circuit protection in commercial and industrial electrical systems. Rated at 45 Amps with a 2-pole configuration, this bolt-on breaker is intended for use in GE A-Series and Spectra Series panelboards. It maintains original system compatibility while offering dependable protection for AC and DC circuits up to 480VAC and 250VDC.\u003c\/p\u003e\n\u003cp data-start=\"621\" data-end=\"643\"\u003e\u003cstrong data-start=\"621\" data-end=\"643\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"645\" data-end=\"811\"\u003e\n\u003cli data-section-id=\"fsvd2t\" data-start=\"645\" data-end=\"672\"\u003eCurrent Rating: 45 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"k9ih7g\" data-start=\"673\" data-end=\"717\"\u003eVoltage Rating: 240VAC \/ 480VAC \/ 250VDC\u003c\/li\u003e\n\u003cli data-section-id=\"ywwcfs\" data-start=\"718\" data-end=\"811\"\u003eInterrupting Rating:\n\u003cul data-start=\"745\" data-end=\"811\"\u003e\n\u003cli data-section-id=\"17skox0\" data-start=\"745\" data-end=\"765\"\u003e18 kAIC @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"td1xta\" data-start=\"768\" data-end=\"788\"\u003e18 kAIC @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1o1end4\" data-start=\"791\" data-end=\"811\"\u003e10 kAIC @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"818\" data-end=\"840\"\u003e\u003cstrong data-start=\"818\" data-end=\"840\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"842\" data-end=\"1227\"\u003e\n\u003cli data-section-id=\"balgxi\" data-start=\"842\" data-end=\"871\"\u003eCatalog Number: TED124045\u003c\/li\u003e\n\u003cli data-section-id=\"1p9tho6\" data-start=\"872\" data-end=\"910\"\u003eBrand: General Electric (ABB \/ GE)\u003c\/li\u003e\n\u003cli data-section-id=\"auzzx7\" data-start=\"911\" data-end=\"926\"\u003eSeries: TED\u003c\/li\u003e\n\u003cli data-section-id=\"juuyua\" data-start=\"927\" data-end=\"972\"\u003eProduct Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"g2auwh\" data-start=\"973\" data-end=\"1005\"\u003eFrame Type: E-Frame (Legacy)\u003c\/li\u003e\n\u003cli data-section-id=\"kjxaur\" data-start=\"1006\" data-end=\"1033\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"ldafex\" data-start=\"1034\" data-end=\"1052\"\u003ePhase: 1-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1053\" data-end=\"1080\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1b3baop\" data-start=\"1081\" data-end=\"1118\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1v51vif\" data-start=\"1119\" data-end=\"1172\"\u003eTrip Function Code: LI (Long-Time, Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"14loojq\" data-start=\"1173\" data-end=\"1227\"\u003eTrip Adjustability: Fixed Thermal \u0026amp; Fixed Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1234\" data-end=\"1257\"\u003e\u003cstrong data-start=\"1234\" data-end=\"1257\"\u003eProtection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1259\" data-end=\"1439\"\u003e\n\u003cli data-section-id=\"1248oou\" data-start=\"1259\" data-end=\"1302\"\u003eThermal magnetic overcurrent protection\u003c\/li\u003e\n\u003cli data-section-id=\"199m2jx\" data-start=\"1303\" data-end=\"1351\"\u003eFixed trip settings for consistent operation\u003c\/li\u003e\n\u003cli data-section-id=\"1ae3xvt\" data-start=\"1352\" data-end=\"1378\"\u003eHACR rated performance\u003c\/li\u003e\n\u003cli data-section-id=\"p49nm0\" data-start=\"1379\" data-end=\"1414\"\u003eNon-interchangeable trip design\u003c\/li\u003e\n\u003cli data-section-id=\"10fzyt1\" data-start=\"1415\" data-end=\"1439\"\u003eReverse feed capable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1446\" data-end=\"1469\"\u003e\u003cstrong data-start=\"1446\" data-end=\"1469\"\u003eConnection \u0026amp; Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1471\" data-end=\"1658\"\u003e\n\u003cli data-section-id=\"1nbdjus\" data-start=\"1471\" data-end=\"1494\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"1df7w3g\" data-start=\"1495\" data-end=\"1548\"\u003eWire Range:\n\u003cul data-start=\"1513\" data-end=\"1548\"\u003e\n\u003cli data-section-id=\"quibqv\" data-start=\"1513\" data-end=\"1529\"\u003eCu: 14–3 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"vdgxyg\" data-start=\"1532\" data-end=\"1548\"\u003eAl: 12–1 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ttpa65\" data-start=\"1549\" data-end=\"1585\"\u003eMax Wire: 3 AWG (Cu), 1 AWG (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"16e1yo7\" data-start=\"1586\" data-end=\"1624\"\u003eMin Wire: 14 AWG (Cu), 12 AWG (Al)\u003c\/li\u003e\n\u003cli data-section-id=\"1e9v89t\" data-start=\"1625\" data-end=\"1658\"\u003eAccessories: TCAL12 load lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1665\" data-end=\"1687\"\u003e\u003cstrong data-start=\"1665\" data-end=\"1687\"\u003eTechnical Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1689\" data-end=\"1867\"\u003e\n\u003cli data-section-id=\"fjqkzc\" data-start=\"1689\" data-end=\"1720\"\u003eBolt-on installation design\u003c\/li\u003e\n\u003cli data-section-id=\"fix0o\" data-start=\"1721\" data-end=\"1776\"\u003eCompatible with GE A-Series and Spectra panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"in7hi7\" data-start=\"1777\" data-end=\"1816\"\u003eHeavy-duty molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"4xuf49\" data-start=\"1817\" data-end=\"1867\"\u003eIndustrial-grade durability for legacy systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1874\" data-end=\"1904\"\u003e\u003cstrong data-start=\"1874\" data-end=\"1904\"\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1906\" data-end=\"2015\"\u003e\n\u003cli data-section-id=\"j8lt5v\" data-start=\"1906\" data-end=\"1916\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1kuinwb\" data-start=\"1917\" data-end=\"1936\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1eaolqv\" data-start=\"1937\" data-end=\"1950\"\u003eNEMA AB-1\u003c\/li\u003e\n\u003cli data-section-id=\"mq9pch\" data-start=\"1951\" data-end=\"1965\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1tswvpf\" data-start=\"1966\" data-end=\"1987\"\u003eCSA \/ UL Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1sab303\" data-start=\"1988\" data-end=\"2015\"\u003e40°C temperature rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2022\" data-end=\"2038\"\u003e\u003cstrong data-start=\"2022\" data-end=\"2038\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2040\" data-end=\"2260\"\u003e\n\u003cli data-section-id=\"ov2tsh\" data-start=\"2040\" data-end=\"2086\"\u003eCommercial electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1vyrbuv\" data-start=\"2087\" data-end=\"2130\"\u003eIndustrial panelboards and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"18xv2zo\" data-start=\"2131\" data-end=\"2163\"\u003eMotor control centers (MCCs)\u003c\/li\u003e\n\u003cli data-section-id=\"1h3dvie\" data-start=\"2164\" data-end=\"2202\"\u003eHVAC and equipment branch circuits\u003c\/li\u003e\n\u003cli data-section-id=\"rds6ts\" data-start=\"2203\" data-end=\"2260\"\u003eLegacy GE system maintenance and retrofit replacement\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48434647138553,"sku":"TED124045","price":362.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/TEB122035_1_1024x_8c49e8e4-b2ea-473a-b485-b8dad7c23f4a.jpg?v=1779537813","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-ted124045-45a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-480vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}