{"product_id":"general-electric-ted124070-70a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-480vac","title":"General Electric TED124070 70A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On – 480VAC","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-6a0f3d4f-7134-83ec-ae9a-05f0895f2050-38\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a0f3d4f-7134-83ec-ae9a-05f0895f2050-38\" data-turn-id-container=\"request-6a0f3d4f-7134-83ec-ae9a-05f0895f2050-38\" data-testid=\"conversation-turn-114\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"46972dfa-0ed9-48bb-8793-cdd45b3d5f37\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"119\" data-end=\"665\"\u003eThe General Electric TED124070 is an E-Frame series molded case circuit breaker designed for reliable overcurrent protection in commercial and industrial electrical distribution systems. Rated at 70 Amps with a 2-pole configuration, this breaker is intended for use in GE A-Series and Spectra Series panelboards, switchboards, and motor control centers. It provides dependable protection for AC and DC circuits operating up to 480VAC and 250VDC, ensuring safe and stable performance in demanding electrical applications.\u003c\/p\u003e\n\u003cp data-start=\"672\" data-end=\"694\"\u003e\u003cstrong data-start=\"672\" data-end=\"694\"\u003eVoltage and Rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"696\" data-end=\"839\"\u003e\n\u003cli data-section-id=\"sn9zwz\" data-start=\"696\" data-end=\"723\"\u003eCurrent Rating: 70 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"t066nl\" data-start=\"724\" data-end=\"759\"\u003eVoltage Rating: 480VAC \/ 250VDC\u003c\/li\u003e\n\u003cli data-section-id=\"3liduw\" data-start=\"760\" data-end=\"839\"\u003eInterrupting Rating: Based on E-Frame system rating (application dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"846\" data-end=\"868\"\u003e\u003cstrong data-start=\"846\" data-end=\"868\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"870\" data-end=\"1213\"\u003e\n\u003cli data-section-id=\"bahn0w\" data-start=\"870\" data-end=\"899\"\u003eCatalog Number: TED124070\u003c\/li\u003e\n\u003cli data-section-id=\"1fufhq3\" data-start=\"900\" data-end=\"927\"\u003eBrand: General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1jvp0o\" data-start=\"928\" data-end=\"978\"\u003eProduct Type: Thermal Magnetic Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"1oo3d2z\" data-start=\"979\" data-end=\"1011\"\u003eProduct Line: E150 \/ E-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"bpyoo5\" data-start=\"1012\" data-end=\"1035\"\u003eFrame Type: E-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"kjxaur\" data-start=\"1036\" data-end=\"1063\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"sybr12\" data-start=\"1064\" data-end=\"1091\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1b3baop\" data-start=\"1092\" data-end=\"1129\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"10mcaq2\" data-start=\"1130\" data-end=\"1178\"\u003eTrip Function: LI (Long-Time, Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"rhuepe\" data-start=\"1179\" data-end=\"1213\"\u003eSuitable for Reverse Feed: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1220\" data-end=\"1243\"\u003e\u003cstrong data-start=\"1220\" data-end=\"1243\"\u003eProtection Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1245\" data-end=\"1467\"\u003e\n\u003cli data-section-id=\"2llf8k\" data-start=\"1245\" data-end=\"1286\"\u003eFixed thermal and magnetic protection\u003c\/li\u003e\n\u003cli data-section-id=\"1b087q3\" data-start=\"1287\" data-end=\"1337\"\u003eReliable short-circuit and overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"11v79sr\" data-start=\"1338\" data-end=\"1381\"\u003eTrip-free mechanism for enhanced safety\u003c\/li\u003e\n\u003cli data-section-id=\"1yjibq8\" data-start=\"1382\" data-end=\"1421\"\u003eDesigned for AC and DC applications\u003c\/li\u003e\n\u003cli data-section-id=\"13e077s\" data-start=\"1422\" data-end=\"1467\"\u003eHACR rated performance (where applicable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1474\" data-end=\"1497\"\u003e\u003cstrong data-start=\"1474\" data-end=\"1497\"\u003eConnection \u0026amp; Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1499\" data-end=\"1614\"\u003e\n\u003cli data-section-id=\"em4cju\" data-start=\"1499\" data-end=\"1554\"\u003eLine and load lugs included where WL suffix applies\u003c\/li\u003e\n\u003cli data-section-id=\"1d5n4ca\" data-start=\"1555\" data-end=\"1614\"\u003eTemperature rating: 60\/75°C up to 100A, 75°C above 100A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1621\" data-end=\"1643\"\u003e\u003cstrong data-start=\"1621\" data-end=\"1643\"\u003eTechnical Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1645\" data-end=\"1812\"\u003e\n\u003cli data-section-id=\"in7hi7\" data-start=\"1645\" data-end=\"1684\"\u003eHeavy-duty molded case construction\u003c\/li\u003e\n\u003cli data-section-id=\"12lmzw3\" data-start=\"1685\" data-end=\"1744\"\u003eCompatible with GE E-Frame panelboards and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"p49nm0\" data-start=\"1745\" data-end=\"1780\"\u003eNon-interchangeable trip design\u003c\/li\u003e\n\u003cli data-section-id=\"1afmk7l\" data-start=\"1781\" data-end=\"1812\"\u003eIndustrial-grade durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1819\" data-end=\"1849\"\u003e\u003cstrong data-start=\"1819\" data-end=\"1849\"\u003eCertifications \u0026amp; Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1851\" data-end=\"1932\"\u003e\n\u003cli data-section-id=\"j8lt5v\" data-start=\"1851\" data-end=\"1861\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1kuinwb\" data-start=\"1862\" data-end=\"1881\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1tswvpf\" data-start=\"1882\" data-end=\"1903\"\u003eCSA \/ UL Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1eaolqv\" data-start=\"1904\" data-end=\"1917\"\u003eNEMA AB-1\u003c\/li\u003e\n\u003cli data-section-id=\"mq9pch\" data-start=\"1918\" data-end=\"1932\"\u003eHACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1939\" data-end=\"1955\"\u003e\u003cstrong data-start=\"1939\" data-end=\"1955\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1957\" data-end=\"2159\"\u003e\n\u003cli data-section-id=\"1g63lej\" data-start=\"1957\" data-end=\"1998\"\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"18xv2zo\" data-start=\"1999\" data-end=\"2031\"\u003eMotor control centers (MCCs)\u003c\/li\u003e\n\u003cli data-section-id=\"1bwb0os\" data-start=\"2032\" data-end=\"2075\"\u003eCommercial switchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1h3dvie\" data-start=\"2076\" data-end=\"2114\"\u003eHVAC and equipment branch circuits\u003c\/li\u003e\n\u003cli data-section-id=\"4ucm6t\" data-start=\"2115\" data-end=\"2159\"\u003eGeneral-purpose AC\/DC protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"NEW","offer_id":48434700452089,"sku":"TED124070","price":446.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/TEB122035_1_1024x_3e767dcc-6acc-4635-8ba8-3b3efe2dba6e.jpg?v=1779537981","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-ted124070-70a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-480vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}