{"product_id":"general-electric-tfj236100wl-100a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","title":"General Electric TFJ236100WL 100A 3-Pole Molded Case Circuit Breaker – Bolt-On Mount – 600VAC","description":"\u003cp data-start=\"139\" data-end=\"760\"\u003eThe General Electric TFJ236100WL is a rugged molded case circuit breaker engineered for dependable overload and short-circuit protection in commercial and industrial electrical distribution systems. Built on the TFJ frame platform, this 3-pole breaker includes a thermal magnetic non-interchangeable trip unit rated at 100 amperes at 40°C. Its bolt-on mounting design provides secure panel installation, while standard line and load end terminals simplify field wiring. With strong AC and DC interrupting ratings, this breaker is an excellent solution for demanding power distribution applications operating up to 600VAC.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wc2bmo\" data-start=\"762\" data-end=\"789\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul data-start=\"790\" data-end=\"1057\"\u003e\n\u003cli data-section-id=\"4phu2k\" data-start=\"790\" data-end=\"817\"\u003eBrand: General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"hk608o\" data-start=\"818\" data-end=\"840\"\u003eModel: TFJ236100WL\u003c\/li\u003e\n\u003cli data-section-id=\"17bc5mf\" data-start=\"841\" data-end=\"862\"\u003eAmperage: 100 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"1mjvejc\" data-start=\"863\" data-end=\"890\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1ovneva\" data-start=\"891\" data-end=\"936\"\u003eBreaker Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"4kab9a\" data-start=\"937\" data-end=\"960\"\u003eMount Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"8h5a42\" data-start=\"961\" data-end=\"980\"\u003eVoltage: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"981\" data-end=\"1004\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1behfaz\" data-start=\"1005\" data-end=\"1034\"\u003eFrame Type: F \/ TFJ Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1am5t8t\" data-start=\"1035\" data-end=\"1057\"\u003eWarranty: One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1059\" data-end=\"1088\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1089\" data-end=\"1433\"\u003e\n\u003cli data-section-id=\"7epll8\" data-start=\"1089\" data-end=\"1145\"\u003eTrip Unit Type: Thermal Magnetic Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"3neoa0\" data-start=\"1146\" data-end=\"1204\"\u003eProtection Type: Overload and Short Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"5jnly8\" data-start=\"1205\" data-end=\"1225\"\u003eFrame Style: TFJ\u003c\/li\u003e\n\u003cli data-section-id=\"nx5s05\" data-start=\"1226\" data-end=\"1254\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"5t4zrt\" data-start=\"1255\" data-end=\"1287\"\u003eTrip Setting Range: 600-1250\u003c\/li\u003e\n\u003cli data-section-id=\"1btdhyk\" data-start=\"1288\" data-end=\"1347\"\u003eStandard Lug Type: Line and Load End Terminals Included\u003c\/li\u003e\n\u003cli data-section-id=\"102sn8z\" data-start=\"1348\" data-end=\"1386\"\u003eOperating Temperature Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"dkdizs\" data-start=\"1387\" data-end=\"1433\"\u003eConstruction: Heavy-Duty Industrial Design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11flra0\" data-start=\"1435\" data-end=\"1459\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-start=\"1460\" data-end=\"1604\"\u003e\n\u003cli data-section-id=\"1sm05jb\" data-start=\"1460\" data-end=\"1479\"\u003e25 kA @ 240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1jqctre\" data-start=\"1480\" data-end=\"1499\"\u003e22 kA @ 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"8z5ze1\" data-start=\"1500\" data-end=\"1519\"\u003e18 kA @ 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"11ei38l\" data-start=\"1520\" data-end=\"1539\"\u003e10 kA @ 250V DC\u003c\/li\u003e\n\u003cli data-section-id=\"1ypb0kc\" data-start=\"1540\" data-end=\"1573\"\u003eMaximum Rated Voltage: 600VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5wq7\" data-start=\"1574\" data-end=\"1604\"\u003eFrequency Rating: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"165x1by\" data-start=\"1606\" data-end=\"1623\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"1624\" data-end=\"2047\"\u003e\n\u003cli data-section-id=\"1h04lci\" data-start=\"1624\" data-end=\"1661\"\u003eManufacturer: General Electric GE\u003c\/li\u003e\n\u003cli data-section-id=\"159yyyr\" data-start=\"1662\" data-end=\"1690\"\u003ePart Number: TFJ236100WL\u003c\/li\u003e\n\u003cli data-section-id=\"1dl4aw9\" data-start=\"1691\" data-end=\"1769\"\u003eCondition: New Surplus \/ Certified Reconditioned (subject to availability)\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"1770\" data-end=\"1782\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"psyc29\" data-start=\"1783\" data-end=\"1810\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"7ihhj1\" data-start=\"1811\" data-end=\"1871\"\u003eIncluded Terminals: Line and Load End Terminals Standard\u003c\/li\u003e\n\u003cli data-section-id=\"7ymwvx\" data-start=\"1872\" data-end=\"1933\"\u003eApplication: Commercial and Industrial Power Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"19yvg30\" data-start=\"1934\" data-end=\"1981\"\u003eWarranty Coverage: 1 Year In-House Warranty\u003c\/li\u003e\n\u003cli data-section-id=\"1vmcv3o\" data-start=\"1982\" data-end=\"2047\"\u003eSuitable For: Panelboards, Switchgear, Distribution Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2049\" data-end=\"2068\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2069\" data-end=\"2412\" data-is-last-node=\"\" data-is-only-node=\"\"\u003ePlease verify compatibility with your electrical panel, frame type, voltage requirements, and current rating before purchase. This breaker includes standard line and load terminals. Installation should be completed by a qualified electrician in accordance with local electrical codes and safety regulations for proper operation and protection.\u003c\/p\u003e","brand":"General Electric GE","offers":[{"title":"New Surplus","offer_id":48343783932153,"sku":"TFJ236100WL-NS","price":3299.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48343783964921,"sku":"TFJ236100WL-CR","price":1599.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/tfj_17.jpg?v=1777710766","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-tfj236100wl-100a-3-pole-molded-case-circuit-breaker-bolt-on-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}