{"product_id":"general-electric-thjk436150wl-150a-3-pole-molded-case-circuit-breaker-bolt-on-mount-480vac","title":"General Electric THJK436150WL 150A 3-Pole Molded Case Circuit Breaker – Bolt-On Mount – 480VAC","description":"\u003cp data-start=\"140\" data-end=\"835\"\u003eThe General Electric THJK436150WL is a heavy-duty molded case circuit breaker engineered for reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. Built on the THJK Hi-Break frame platform, this 3-pole breaker features a thermal magnetic interchangeable trip unit rated at 150 amperes at 40°C. Its bolt-on mounting design provides secure installation in panelboards and switchgear assemblies, while standard line and load end terminals allow efficient field wiring. With strong interrupting capacity ratings across AC and DC systems, this breaker is ideal for feeder and branch circuit protection in demanding power applications up to 600V.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wc2bmo\" data-start=\"837\" data-end=\"864\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul data-start=\"865\" data-end=\"1143\"\u003e\n\u003cli data-section-id=\"4phu2k\" data-start=\"865\" data-end=\"892\"\u003eBrand: General Electric\u003c\/li\u003e\n\u003cli data-section-id=\"xyx5xa\" data-start=\"893\" data-end=\"916\"\u003eModel: THJK436150WL\u003c\/li\u003e\n\u003cli data-section-id=\"c2a6j6\" data-start=\"917\" data-end=\"938\"\u003eAmperage: 150 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"1mjvejc\" data-start=\"939\" data-end=\"966\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1ovneva\" data-start=\"967\" data-end=\"1012\"\u003eBreaker Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"4kab9a\" data-start=\"1013\" data-end=\"1036\"\u003eMount Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"19sy5dk\" data-start=\"1037\" data-end=\"1056\"\u003eVoltage: 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1057\" data-end=\"1080\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1q7d3kx\" data-start=\"1081\" data-end=\"1120\"\u003eFrame Type: J \/ THJK Hi-Break Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1am5t8t\" data-start=\"1121\" data-end=\"1143\"\u003eWarranty: One Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1145\" data-end=\"1174\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1175\" data-end=\"1525\"\u003e\n\u003cli data-section-id=\"9vnpf2\" data-start=\"1175\" data-end=\"1227\"\u003eTrip Unit Type: Thermal Magnetic Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"3neoa0\" data-start=\"1228\" data-end=\"1286\"\u003eProtection Type: Overload and Short Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"59f77a\" data-start=\"1287\" data-end=\"1317\"\u003eFrame Style: THJK Hi-Break\u003c\/li\u003e\n\u003cli data-section-id=\"nx5s05\" data-start=\"1318\" data-end=\"1346\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1ov8pto\" data-start=\"1347\" data-end=\"1379\"\u003eTrip Setting Range: 450-1500\u003c\/li\u003e\n\u003cli data-section-id=\"1btdhyk\" data-start=\"1380\" data-end=\"1439\"\u003eStandard Lug Type: Line and Load End Terminals Included\u003c\/li\u003e\n\u003cli data-section-id=\"102sn8z\" data-start=\"1440\" data-end=\"1478\"\u003eOperating Temperature Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"dkdizs\" data-start=\"1479\" data-end=\"1525\"\u003eConstruction: Heavy-Duty Industrial Design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11flra0\" data-start=\"1527\" data-end=\"1551\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-start=\"1552\" data-end=\"1732\"\u003e\n\u003cli data-section-id=\"9fn56r\" data-start=\"1552\" data-end=\"1571\"\u003e65 kA @ 240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1h7qsss\" data-start=\"1572\" data-end=\"1591\"\u003e35 kA @ 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1jh7u6f\" data-start=\"1592\" data-end=\"1611\"\u003e25 kA @ 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1a3hizk\" data-start=\"1612\" data-end=\"1631\"\u003e40 kA @ 250V DC\u003c\/li\u003e\n\u003cli data-section-id=\"xi3ern\" data-start=\"1632\" data-end=\"1669\"\u003eNominal Operating Voltage: 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"vtvh4u\" data-start=\"1670\" data-end=\"1701\"\u003eMaximum Rated Voltage: 600V\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5wq7\" data-start=\"1702\" data-end=\"1732\"\u003eFrequency Rating: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"165x1by\" data-start=\"1734\" data-end=\"1751\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"1752\" data-end=\"2194\"\u003e\n\u003cli data-section-id=\"1h04lci\" data-start=\"1752\" data-end=\"1789\"\u003eManufacturer: General Electric GE\u003c\/li\u003e\n\u003cli data-section-id=\"1tr4vhh\" data-start=\"1790\" data-end=\"1819\"\u003ePart Number: THJK436150WL\u003c\/li\u003e\n\u003cli data-section-id=\"1dl4aw9\" data-start=\"1820\" data-end=\"1898\"\u003eCondition: New Surplus \/ Certified Reconditioned (subject to availability)\u003c\/li\u003e\n\u003cli data-section-id=\"ksy8o4\" data-start=\"1899\" data-end=\"1911\"\u003ePoles: 3\u003c\/li\u003e\n\u003cli data-section-id=\"psyc29\" data-start=\"1912\" data-end=\"1939\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"7ihhj1\" data-start=\"1940\" data-end=\"2000\"\u003eIncluded Terminals: Line and Load End Terminals Standard\u003c\/li\u003e\n\u003cli data-section-id=\"7ymwvx\" data-start=\"2001\" data-end=\"2062\"\u003eApplication: Commercial and Industrial Power Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"19yvg30\" data-start=\"2063\" data-end=\"2110\"\u003eWarranty Coverage: 1 Year In-House Warranty\u003c\/li\u003e\n\u003cli data-section-id=\"1b9as2b\" data-start=\"2111\" data-end=\"2194\"\u003eSuitable For: Panelboards, Switchgear, Motor Control and Distribution Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2196\" data-end=\"2215\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2216\" data-end=\"2595\" data-is-last-node=\"\" data-is-only-node=\"\"\u003ePlease verify compatibility with your electrical system, panel configuration, frame type, voltage requirements, and trip settings before purchase. This breaker includes standard line and load terminals. Installation must be performed by a qualified electrician in accordance with applicable electrical codes and safety standards to ensure safe, reliable, and compliant operation.\u003c\/p\u003e","brand":"General Electric GE","offers":[{"title":"New Surplus","offer_id":48345306398969,"sku":"THJK436150WL-NS","price":3199.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48345306431737,"sku":"THJK436150WL-CR","price":2099.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/tjk436_4_6.webp?v=1777748232","url":"https:\/\/mycircuitbreakers.com\/products\/general-electric-thjk436150wl-150a-3-pole-molded-case-circuit-breaker-bolt-on-mount-480vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}