{"product_id":"schneider-electric-lrd332-thermal-overload-relay-23-32a-tesys-deca-series-din-rail-plate-mount-motor-protection-relay-for-lc1d40a-50a-65a-contactors","title":"Schneider Electric LRD332 Thermal Overload Relay – 23–32A – TeSys Deca Series – DIN Rail\/Plate Mount – Motor Protection Relay for LC1D40A\/50A\/65A Contactors","description":"\u003cp data-start=\"183\" data-end=\"529\"\u003eThe Schneider Electric LRD332 is a 3-pole thermal overload relay from the TeSys Deca series, designed to protect three-phase motors from overload conditions. It works in combination with LC1D-series contactors to ensure safe motor operation by disconnecting the circuit when excessive current or prolonged overload is detected.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vwh4os\" data-start=\"536\" data-end=\"562\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"540\" data-end=\"562\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"563\" data-end=\"796\"\u003e\n\u003cli data-section-id=\"ge7bgg\" data-start=\"563\" data-end=\"597\"\u003eCurrent Setting Range: 23–32 A\u003c\/li\u003e\n\u003cli data-section-id=\"5pxcnv\" data-start=\"598\" data-end=\"638\"\u003eVoltage Rating: up to 600 \/ 690 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"639\" data-end=\"657\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"14zhvum\" data-start=\"658\" data-end=\"702\"\u003ePoles: 3 Pole (thermal sensing elements)\u003c\/li\u003e\n\u003cli data-section-id=\"mbxuyx\" data-start=\"703\" data-end=\"751\"\u003eProtection Type: Thermal overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1izxr8b\" data-start=\"752\" data-end=\"796\"\u003eApplication Type: Motor protection relay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pog7sv\" data-start=\"803\" data-end=\"837\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"807\" data-end=\"837\"\u003eConfiguration and Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"838\" data-end=\"1153\"\u003e\n\u003cli data-section-id=\"cnt9v6\" data-start=\"838\" data-end=\"877\"\u003eDevice Type: Thermal Overload Relay\u003c\/li\u003e\n\u003cli data-section-id=\"1dqj72a\" data-start=\"878\" data-end=\"900\"\u003eSeries: TeSys Deca\u003c\/li\u003e\n\u003cli data-section-id=\"18gi1ug\" data-start=\"901\" data-end=\"958\"\u003ePrimary Function: Motor overload and phase protection\u003c\/li\u003e\n\u003cli data-section-id=\"alvueg\" data-start=\"959\" data-end=\"1027\"\u003eReset Function: Manual\/automatic reset (configuration dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"gcb4lw\" data-start=\"1028\" data-end=\"1076\"\u003eTrip Mechanism: Thermal bimetallic operation\u003c\/li\u003e\n\u003cli data-section-id=\"1r7jfxc\" data-start=\"1077\" data-end=\"1153\"\u003eTrip Indication: Mechanical\/electrical indication via auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"n07754\" data-start=\"1160\" data-end=\"1181\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1164\" data-end=\"1181\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1182\" data-end=\"1416\"\u003e\n\u003cli data-section-id=\"15oz5yh\" data-start=\"1182\" data-end=\"1283\"\u003eSuitable For Use With:\n\u003cul data-start=\"1211\" data-end=\"1283\"\u003e\n\u003cli data-section-id=\"auiqm1\" data-start=\"1211\" data-end=\"1233\"\u003eLC1D40A contactors\u003c\/li\u003e\n\u003cli data-section-id=\"1tog1qw\" data-start=\"1236\" data-end=\"1258\"\u003eLC1D50A contactors\u003c\/li\u003e\n\u003cli data-section-id=\"17t5mny\" data-start=\"1261\" data-end=\"1283\"\u003eLC1D65A contactors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n54s9d\" data-start=\"1284\" data-end=\"1352\"\u003eSystem Type: Motor starter assembly (contactor + overload relay)\u003c\/li\u003e\n\u003cli data-section-id=\"1o59v53\" data-start=\"1353\" data-end=\"1416\"\u003eInstallation: Direct mounting to compatible LC1D contactors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i5ken1\" data-start=\"1423\" data-end=\"1470\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1427\" data-end=\"1470\"\u003eMechanical and Physical Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1471\" data-end=\"1778\"\u003e\n\u003cli data-section-id=\"11twh18\" data-start=\"1471\" data-end=\"1512\"\u003eMounting Type: DIN Rail \/ Plate Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1tbp52y\" data-start=\"1513\" data-end=\"1553\"\u003eTerminal Type: Screw clamp terminals\u003c\/li\u003e\n\u003cli data-section-id=\"19gdo66\" data-start=\"1554\" data-end=\"1609\"\u003eDimensions: 4.84 in (L) × 2.17 in (W) × 4.84 in (H)\u003c\/li\u003e\n\u003cli data-section-id=\"12wwmj2\" data-start=\"1610\" data-end=\"1658\"\u003eOperating Temperature Range: -20 °C to 60 °C\u003c\/li\u003e\n\u003cli data-section-id=\"r0u766\" data-start=\"1659\" data-end=\"1718\"\u003eCompact industrial design for control panel integration\u003c\/li\u003e\n\u003cli data-section-id=\"1vhxlhl\" data-start=\"1719\" data-end=\"1778\"\u003eHigh mechanical durability for motor protection systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"edib4p\" data-start=\"1785\" data-end=\"1813\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1789\" data-end=\"1813\"\u003eContacts and Control\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1814\" data-end=\"2004\"\u003e\n\u003cli data-section-id=\"19qogto\" data-start=\"1814\" data-end=\"1849\"\u003eAuxiliary Contacts: 1 NO + 1 NC\u003c\/li\u003e\n\u003cli data-section-id=\"13wiq7m\" data-start=\"1850\" data-end=\"1908\"\u003eContact Function: Trip signaling and control interlock\u003c\/li\u003e\n\u003cli data-section-id=\"1uq0x7r\" data-start=\"1909\" data-end=\"1955\"\u003eReset Type: Manual or automatic selectable\u003c\/li\u003e\n\u003cli data-section-id=\"1bn9wvc\" data-start=\"1956\" data-end=\"2004\"\u003eBuilt-in indication for overload trip status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"13jmbe6\" data-start=\"2011\" data-end=\"2047\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2047\"\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2048\" data-end=\"2313\"\u003e\n\u003cli data-section-id=\"1g15q4g\" data-start=\"2048\" data-end=\"2093\"\u003eIEC \/ EN \/ UL \/ CSA \/ CCC \/ EAC compliant\u003c\/li\u003e\n\u003cli data-section-id=\"okv00s\" data-start=\"2094\" data-end=\"2134\"\u003eMarine approvals: DNV-GL, LROS, RMRS\u003c\/li\u003e\n\u003cli data-section-id=\"s1euvg\" data-start=\"2135\" data-end=\"2162\"\u003eATEX certified (INERIS)\u003c\/li\u003e\n\u003cli data-section-id=\"kd8p17\" data-start=\"2163\" data-end=\"2181\"\u003eUKCA compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1lolzyr\" data-start=\"2182\" data-end=\"2208\"\u003eRoHS \/ REACh compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"2209\" data-end=\"2245\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1dqj72a\" data-start=\"2246\" data-end=\"2268\"\u003eSeries: TeSys Deca\u003c\/li\u003e\n\u003cli data-section-id=\"1yxbtih\" data-start=\"2269\" data-end=\"2284\"\u003eMPN: LRD332\u003c\/li\u003e\n\u003cli data-section-id=\"4sj3rb\" data-start=\"2285\" data-end=\"2313\"\u003eUPC \/ GTIN: 785901811640\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kylm4h\" data-start=\"2320\" data-end=\"2336\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2324\" data-end=\"2336\"\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2337\" data-end=\"2901\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"12ygw1e\" data-start=\"2337\" data-end=\"2392\"\u003eAdjustable 23–32A thermal overload protection range\u003c\/li\u003e\n\u003cli data-section-id=\"8ms2ie\" data-start=\"2393\" data-end=\"2445\"\u003eDesigned for use with LC1D40A\/50A\/65A contactors\u003c\/li\u003e\n\u003cli data-section-id=\"1yko0d3\" data-start=\"2446\" data-end=\"2508\"\u003eProvides reliable motor overload and phase loss protection\u003c\/li\u003e\n\u003cli data-section-id=\"ryj7cv\" data-start=\"2509\" data-end=\"2567\"\u003e1NO + 1NC auxiliary contacts for control and signaling\u003c\/li\u003e\n\u003cli data-section-id=\"vlbxa2\" data-start=\"2568\" data-end=\"2605\"\u003eCompact modular TeSys Deca design\u003c\/li\u003e\n\u003cli data-section-id=\"1sawrev\" data-start=\"2606\" data-end=\"2665\"\u003eDirect mounting for fast installation in motor starters\u003c\/li\u003e\n\u003cli data-section-id=\"mc04bv\" data-start=\"2666\" data-end=\"2731\"\u003eHigh reliability for industrial motor protection applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538187464953,"sku":"LRD332","price":121.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/lrd332_1024x_2dc09674-69d8-4649-9443-390a273e2273.webp?v=1781644091","url":"https:\/\/mycircuitbreakers.com\/products\/schneider-electric-lrd332-thermal-overload-relay-23-32a-tesys-deca-series-din-rail-plate-mount-motor-protection-relay-for-lc1d40a-50a-65a-contactors","provider":"My Circuit Breakers","version":"1.0","type":"link"}