{"product_id":"schneider-electric-lrd4367-thermal-overload-relay-tesys-deca-series-din-rail-plate-mount-motor-protection-relay-industrial-motor-starter-protection","title":"Schneider Electric LRD4367 Thermal Overload Relay – TeSys Deca Series – DIN Rail\/Plate Mount – Motor Protection Relay – Industrial Motor Starter Protection","description":"\u003cp data-start=\"182\" data-end=\"550\"\u003eThe Schneider Electric LRD4367 is a TeSys Deca thermal overload relay designed to protect three-phase motors from overload, phase failure, and prolonged stalled conditions. It is used as part of a motor starter system in combination with LC1D-series contactors, providing reliable and consistent protection in industrial and commercial applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vwh4os\" data-start=\"557\" data-end=\"583\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"561\" data-end=\"583\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"584\" data-end=\"829\"\u003e\n\u003cli data-section-id=\"9tpzmx\" data-start=\"584\" data-end=\"616\"\u003eControl Voltage: up to 600 V\u003c\/li\u003e\n\u003cli data-section-id=\"jasehv\" data-start=\"617\" data-end=\"642\"\u003eSupply Voltage: 600 V\u003c\/li\u003e\n\u003cli data-section-id=\"36k9ci\" data-start=\"643\" data-end=\"692\"\u003ePhase: 3 Phase (motor protection application)\u003c\/li\u003e\n\u003cli data-section-id=\"35255r\" data-start=\"693\" data-end=\"735\"\u003ePoles: 3 Pole thermal sensing elements\u003c\/li\u003e\n\u003cli data-section-id=\"mbxuyx\" data-start=\"736\" data-end=\"784\"\u003eProtection Type: Thermal overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1izxr8b\" data-start=\"785\" data-end=\"829\"\u003eApplication Type: Motor protection relay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pog7sv\" data-start=\"836\" data-end=\"870\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"840\" data-end=\"870\"\u003eConfiguration and Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"871\" data-end=\"1233\"\u003e\n\u003cli data-section-id=\"cnt9v6\" data-start=\"871\" data-end=\"910\"\u003eDevice Type: Thermal Overload Relay\u003c\/li\u003e\n\u003cli data-section-id=\"l2n30i\" data-start=\"911\" data-end=\"946\"\u003eSeries: TeSys Deca (LRD Series)\u003c\/li\u003e\n\u003cli data-section-id=\"ot1d19\" data-start=\"947\" data-end=\"1017\"\u003ePrimary Function: Motor overload, phase loss, and stall protection\u003c\/li\u003e\n\u003cli data-section-id=\"gcb4lw\" data-start=\"1018\" data-end=\"1066\"\u003eTrip Mechanism: Thermal bimetallic operation\u003c\/li\u003e\n\u003cli data-section-id=\"1nnsqh4\" data-start=\"1067\" data-end=\"1124\"\u003eReset Function: Manual \/ Automatic (system dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"l8mwh9\" data-start=\"1125\" data-end=\"1191\"\u003eTest Function: Built-in test capability (typical TeSys design)\u003c\/li\u003e\n\u003cli data-section-id=\"o3s4yb\" data-start=\"1192\" data-end=\"1233\"\u003eTrip Indication: Mechanical indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"n07754\" data-start=\"1240\" data-end=\"1261\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1244\" data-end=\"1261\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1262\" data-end=\"1459\"\u003e\n\u003cli data-section-id=\"l77c5k\" data-start=\"1262\" data-end=\"1316\"\u003eDesigned for use in TeSys motor starter assemblies\u003c\/li\u003e\n\u003cli data-section-id=\"1xvvv4u\" data-start=\"1317\" data-end=\"1402\"\u003eCompatible with Schneider Electric LC1D-series contactors (application dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"ryysvg\" data-start=\"1403\" data-end=\"1459\"\u003eSystem Type: Industrial motor control and protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i5ken1\" data-start=\"1466\" data-end=\"1513\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1470\" data-end=\"1513\"\u003eMechanical and Physical Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1514\" data-end=\"1785\"\u003e\n\u003cli data-section-id=\"11twh18\" data-start=\"1514\" data-end=\"1555\"\u003eMounting Type: DIN Rail \/ Plate Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1tbp52y\" data-start=\"1556\" data-end=\"1596\"\u003eTerminal Type: Screw clamp terminals\u003c\/li\u003e\n\u003cli data-section-id=\"12wwmj2\" data-start=\"1597\" data-end=\"1645\"\u003eOperating Temperature Range: -20 °C to 60 °C\u003c\/li\u003e\n\u003cli data-section-id=\"38n3x2\" data-start=\"1646\" data-end=\"1683\"\u003eCompact modular industrial design\u003c\/li\u003e\n\u003cli data-section-id=\"1fyupsd\" data-start=\"1684\" data-end=\"1726\"\u003eSuitable for control panel integration\u003c\/li\u003e\n\u003cli data-section-id=\"f8ywo6\" data-start=\"1727\" data-end=\"1785\"\u003eDurable construction for harsh industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1wzhkoy\" data-start=\"1792\" data-end=\"1828\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1796\" data-end=\"1828\"\u003eControls and Safety Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1829\" data-end=\"2124\"\u003e\n\u003cli data-section-id=\"yng0if\" data-start=\"1829\" data-end=\"1897\"\u003eProvides reliable thermal protection against overload conditions\u003c\/li\u003e\n\u003cli data-section-id=\"1mgxrna\" data-start=\"1898\" data-end=\"1967\"\u003ePhase loss and imbalance protection (typical TeSys functionality)\u003c\/li\u003e\n\u003cli data-section-id=\"nrjjug\" data-start=\"1968\" data-end=\"2035\"\u003eManual or automatic reset capability depending on configuration\u003c\/li\u003e\n\u003cli data-section-id=\"9qe8yk\" data-start=\"2036\" data-end=\"2073\"\u003eMechanical trip status indication\u003c\/li\u003e\n\u003cli data-section-id=\"ye26ph\" data-start=\"2074\" data-end=\"2124\"\u003eDesigned for continuous industrial duty cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"13jmbe6\" data-start=\"2131\" data-end=\"2167\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2135\" data-end=\"2167\"\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2168\" data-end=\"2397\"\u003e\n\u003cli data-section-id=\"29a5ry\" data-start=\"2168\" data-end=\"2197\"\u003eIEC \/ EN compliant design\u003c\/li\u003e\n\u003cli data-section-id=\"8uta8u\" data-start=\"2198\" data-end=\"2243\"\u003eUL \/ CSA approved (application dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"16vnu8c\" data-start=\"2244\" data-end=\"2261\"\u003eCCC certified\u003c\/li\u003e\n\u003cli data-section-id=\"4qu0w\" data-start=\"2262\" data-end=\"2279\"\u003eEAC compliant\u003c\/li\u003e\n\u003cli data-section-id=\"vmmuwx\" data-start=\"2280\" data-end=\"2298\"\u003eRoHS compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1mzzcj3\" data-start=\"2299\" data-end=\"2335\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1dqj72a\" data-start=\"2336\" data-end=\"2358\"\u003eSeries: TeSys Deca\u003c\/li\u003e\n\u003cli data-section-id=\"1ypvkbh\" data-start=\"2359\" data-end=\"2375\"\u003eMPN: LRD4367\u003c\/li\u003e\n\u003cli data-section-id=\"1ybzahc\" data-start=\"2376\" data-end=\"2397\"\u003eUPC: 785901234470\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kylm4h\" data-start=\"2404\" data-end=\"2420\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2420\"\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2421\" data-end=\"2927\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1fkgrqq\" data-start=\"2421\" data-end=\"2483\"\u003eAdvanced thermal overload protection for industrial motors\u003c\/li\u003e\n\u003cli data-section-id=\"5uyiwv\" data-start=\"2484\" data-end=\"2541\"\u003eDesigned for integration with TeSys contactor systems\u003c\/li\u003e\n\u003cli data-section-id=\"1kikydb\" data-start=\"2542\" data-end=\"2592\"\u003eReliable phase failure and overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1tnjjyh\" data-start=\"2593\" data-end=\"2640\"\u003eCompact DIN rail\/plate mounting flexibility\u003c\/li\u003e\n\u003cli data-section-id=\"1yetmv6\" data-start=\"2641\" data-end=\"2699\"\u003eBuilt for long service life in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538201948409,"sku":"LRD4367","price":329.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/70008556.webp?v=1781645084","url":"https:\/\/mycircuitbreakers.com\/products\/schneider-electric-lrd4367-thermal-overload-relay-tesys-deca-series-din-rail-plate-mount-motor-protection-relay-industrial-motor-starter-protection","provider":"My Circuit Breakers","version":"1.0","type":"link"}