{"product_id":"siemens-3va4112-5ed34-0aa0-3va4-molded-case-circuit-breaker-125a-3-pole-thermal-magnetic-bolt-on-600vac","title":"Siemens 3VA4112-5ED34-0AA0 3VA4 Molded Case Circuit Breaker – 125A – 3-Pole – Thermal Magnetic – Bolt-On – 600VAC","description":"\u003cp data-start=\"119\" data-end=\"609\"\u003eThe Siemens 3VA4112-5ED34-0AA0 is a SENTRON 3VA4 series molded case circuit breaker designed for low-voltage commercial and industrial power distribution systems. Featuring a TM210 thermal-magnetic trip unit with fixed long-time and instantaneous protection settings, this breaker provides dependable overload and short-circuit protection. Built on the 3VA41 frame with medium (Class M) breaking capacity, it includes factory-installed load-side lugs for simplified installation and wiring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"611\" data-end=\"633\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"634\" data-end=\"729\"\u003e\n\u003cli data-section-id=\"1f9hxid\" data-start=\"634\" data-end=\"660\"\u003eCurrent Rating: 125 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"w9stpx\" data-start=\"661\" data-end=\"686\"\u003eVoltage Rating: 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"5p1llh\" data-start=\"687\" data-end=\"712\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"nh2u98\" data-start=\"713\" data-end=\"729\"\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1at9qhk\" data-start=\"731\" data-end=\"769\"\u003eInterrupting Capacity (AIC Rating)\u003c\/h3\u003e\n\u003cul data-start=\"770\" data-end=\"857\"\u003e\n\u003cli data-section-id=\"1qa4r97\" data-start=\"770\" data-end=\"788\"\u003e100 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"55svet\" data-start=\"789\" data-end=\"834\"\u003e35 kA @ 480 VAC (Class M Breaking Capacity)\u003c\/li\u003e\n\u003cli data-section-id=\"1a6j0j3\" data-start=\"835\" data-end=\"857\"\u003e18 kA @ 600Y\/347 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"859\" data-end=\"881\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"882\" data-end=\"1234\"\u003e\n\u003cli data-section-id=\"ljdll7\" data-start=\"882\" data-end=\"932\"\u003eProduct Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"l0fpv0\" data-start=\"933\" data-end=\"963\"\u003eSeries: Siemens SENTRON 3VA4\u003c\/li\u003e\n\u003cli data-section-id=\"16xvemv\" data-start=\"964\" data-end=\"997\"\u003ePart Number: 3VA4112-5ED34-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"1mq3x9y\" data-start=\"998\" data-end=\"1017\"\u003eFrame Type: 3VA41\u003c\/li\u003e\n\u003cli data-section-id=\"1pc83wm\" data-start=\"1018\" data-end=\"1055\"\u003eBreaking Capacity: Medium (Class M)\u003c\/li\u003e\n\u003cli data-section-id=\"1eyqpht\" data-start=\"1056\" data-end=\"1081\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1vh5gzl\" data-start=\"1082\" data-end=\"1100\"\u003eTrip Unit: TM210\u003c\/li\u003e\n\u003cli data-section-id=\"1ypgmji\" data-start=\"1101\" data-end=\"1136\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"ogbrib\" data-start=\"1137\" data-end=\"1193\"\u003eProtection Functions: Long-Time (L), Instantaneous (I)\u003c\/li\u003e\n\u003cli data-section-id=\"12l3hh\" data-start=\"1194\" data-end=\"1234\"\u003eTrip Adjustability: Fixed Ir, Fixed Ii\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1236\" data-end=\"1264\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1265\" data-end=\"1423\"\u003e\n\u003cli data-section-id=\"4gi18h\" data-start=\"1265\" data-end=\"1299\"\u003eFactory-Installed Load Side Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"130w6l3\" data-start=\"1300\" data-end=\"1327\"\u003eLoad Side Connection Only\u003c\/li\u003e\n\u003cli data-section-id=\"33mwho\" data-start=\"1328\" data-end=\"1369\"\u003eCompact Low-Voltage Distribution Design\u003c\/li\u003e\n\u003cli data-section-id=\"7iaa0r\" data-start=\"1370\" data-end=\"1423\"\u003eSuitable for Commercial and Industrial Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tsjdab\" data-start=\"1425\" data-end=\"1448\"\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003cul data-start=\"1449\" data-end=\"1516\"\u003e\n\u003cli data-section-id=\"vbwd9a\" data-start=\"1449\" data-end=\"1464\"\u003eWidth: 3.0 in\u003c\/li\u003e\n\u003cli data-section-id=\"1bjvk4\" data-start=\"1465\" data-end=\"1481\"\u003eHeight: 5.5 in\u003c\/li\u003e\n\u003cli data-section-id=\"iqndbm\" data-start=\"1482\" data-end=\"1497\"\u003eDepth: 3.7 in\u003c\/li\u003e\n\u003cli data-section-id=\"m3kd4u\" data-start=\"1498\" data-end=\"1516\"\u003eWeight: 1.638 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"1518\" data-end=\"1543\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1544\" data-end=\"1558\"\u003e\n\u003cli data-section-id=\"1a6fkpe\" data-start=\"1544\" data-end=\"1558\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1560\" data-end=\"1572\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1573\" data-end=\"2227\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"ovm24m\" data-start=\"1573\" data-end=\"1652\"\u003eThermal-magnetic trip unit for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"s0h3sd\" data-start=\"1653\" data-end=\"1709\"\u003eFixed long-time and instantaneous protection functions\u003c\/li\u003e\n\u003cli data-section-id=\"8i5nwu\" data-start=\"1710\" data-end=\"1753\"\u003eMedium (Class M) breaking capacity design\u003c\/li\u003e\n\u003cli data-section-id=\"11lp2wu\" data-start=\"1754\" data-end=\"1825\"\u003eHigh interrupting capability for demanding power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1gvoycv\" data-start=\"1826\" data-end=\"1888\"\u003eFactory-installed load-side lugs simplify field installation\u003c\/li\u003e\n\u003cli data-section-id=\"111c8kj\" data-start=\"1889\" data-end=\"1941\"\u003eCompact 3VA41 frame conserves valuable panel space\u003c\/li\u003e\n\u003cli data-section-id=\"8cnbju\" data-start=\"1942\" data-end=\"2021\"\u003eSuitable for panelboards, switchboards, and industrial distribution equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1ozwuku\" data-start=\"2022\" data-end=\"2086\"\u003eDurable Siemens SENTRON construction for extended service life\u003c\/li\u003e\n\u003cli data-section-id=\"jo2n74\" data-start=\"2087\" data-end=\"2157\"\u003eDesigned for commercial, industrial, and OEM electrical applications\u003c\/li\u003e\n\u003cli data-section-id=\"j7tspc\" data-start=\"2158\" data-end=\"2227\" data-is-last-node=\"\"\u003eDependable low-voltage protection solution for modern power systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48480240402681,"sku":"3VA4112-5ED34-0AA0","price":803.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA4111-5ED34-0AA0-All-New-1_5500312c-a526-4d61-b6d6-5fedecb53b5d.webp?v=1780504523","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va4112-5ed34-0aa0-3va4-molded-case-circuit-breaker-125a-3-pole-thermal-magnetic-bolt-on-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}