{"product_id":"siemens-3va4125-6ed34-0aa0-25a-3p-molded-case-circuit-breaker-panel-mount-480v-ac","title":"Siemens 3VA4125-6ED34-0AA0 25A 3P Molded Case Circuit Breaker – Panel Mount – 480V AC","description":"\u003cp data-start=\"94\" data-end=\"545\"\u003eThe Siemens 3VA4125-6ED34-0AA0 molded case circuit breaker is part of the SENTRON 3VA4 series, engineered for industrial power distribution and protection. It delivers reliable overcurrent protection using a fixed thermal-magnetic trip unit with LI (long-time and instantaneous) functionality. Designed for use in Siemens P1–P5 panelboards and switchboards, it offers high interrupting capacity and robust performance for demanding electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"547\" data-end=\"746\"\u003eThis breaker is built with current-limiting technology and is suitable for applications requiring dependable fault interruption, system coordination, and safety compliance in industrial environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"753\" data-end=\"775\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"776\" data-end=\"1095\"\u003e\n\u003cli data-section-id=\"1fm3ndm\" data-start=\"776\" data-end=\"799\"\u003eCurrent Rating: 25A\u003c\/li\u003e\n\u003cli data-section-id=\"mwlhud\" data-start=\"800\" data-end=\"827\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1rjhj1o\" data-start=\"828\" data-end=\"846\"\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"fnndbo\" data-start=\"847\" data-end=\"946\"\u003eVoltage Rating:\n\u003cul data-start=\"869\" data-end=\"946\"\u003e\n\u003cli data-section-id=\"1rnghoq\" data-start=\"869\" data-end=\"880\"\u003e240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1q4ufd0\" data-start=\"883\" data-end=\"899\"\u003e480Y\/277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1g4cuio\" data-start=\"902\" data-end=\"913\"\u003e480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"fup12k\" data-start=\"916\" data-end=\"932\"\u003e600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"22jbke\" data-start=\"935\" data-end=\"946\"\u003e250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11ow2en\" data-start=\"947\" data-end=\"1095\"\u003eInterrupting Capacity:\n\u003cul data-start=\"976\" data-end=\"1095\"\u003e\n\u003cli data-section-id=\"v7rvn5\" data-start=\"976\" data-end=\"996\"\u003e100 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1h87o31\" data-start=\"999\" data-end=\"1023\"\u003e65 kA @ 480Y\/277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ga5ma1\" data-start=\"1026\" data-end=\"1045\"\u003e65 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1juu1fl\" data-start=\"1048\" data-end=\"1072\"\u003e25 kA @ 600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"gr01md\" data-start=\"1075\" data-end=\"1095\"\u003e100 kA @ 250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"152tit7\" data-start=\"1102\" data-end=\"1132\"\u003eTrip \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"1133\" data-end=\"1366\"\u003e\n\u003cli data-section-id=\"trkker\" data-start=\"1133\" data-end=\"1170\"\u003eTrip Technology: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1171\" data-end=\"1197\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"5nai79\" data-start=\"1198\" data-end=\"1244\"\u003eProtection Type: Long-Time \u0026amp; Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"h6pbl8\" data-start=\"1245\" data-end=\"1301\"\u003eTrip Adjustability: Fixed thermal and fixed magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"10175cx\" data-start=\"1302\" data-end=\"1327\"\u003eCurrent Limiting: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"35b0qr\" data-start=\"1328\" data-end=\"1347\"\u003eHACR Rated: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"10ftfjy\" data-start=\"1348\" data-end=\"1366\"\u003eHID Rated: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1373\" data-end=\"1395\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1396\" data-end=\"1678\"\u003e\n\u003cli data-section-id=\"13felpp\" data-start=\"1396\" data-end=\"1430\"\u003eSeries: Siemens 3VA4 (SENTRON)\u003c\/li\u003e\n\u003cli data-section-id=\"1tm6t5o\" data-start=\"1431\" data-end=\"1461\"\u003eMounting Type: Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"8duzif\" data-start=\"1462\" data-end=\"1511\"\u003eTerminal Type: Lugs (Load-side lugs included)\u003c\/li\u003e\n\u003cli data-section-id=\"1cza3y0\" data-start=\"1512\" data-end=\"1588\"\u003eCompatible Panels: Siemens P1, P2, P3, P4, P5 panelboards \u0026amp; switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"hrhqd5\" data-start=\"1589\" data-end=\"1678\"\u003eAccessories Options: Shunt trip, auxiliary switch, undervoltage release, alarm switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1mr9dyg\" data-start=\"1685\" data-end=\"1703\"\u003eWiring Details\u003c\/h3\u003e\n\u003cul data-start=\"1704\" data-end=\"1822\"\u003e\n\u003cli data-section-id=\"5x7hxe\" data-start=\"1704\" data-end=\"1733\"\u003eWire Gauge (Cu): 14–8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"cbwqpr\" data-start=\"1734\" data-end=\"1763\"\u003eWire Gauge (Al): 12–8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"19thhsv\" data-start=\"1764\" data-end=\"1792\"\u003eMaximum Wire Size: 8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1j655zw\" data-start=\"1793\" data-end=\"1822\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"1829\" data-end=\"1854\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1855\" data-end=\"1964\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"1855\" data-end=\"1865\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"1866\" data-end=\"1881\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"1882\" data-end=\"1901\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"j6meb1\" data-start=\"1902\" data-end=\"1926\"\u003eCE, CSA, UL Approved\u003c\/li\u003e\n\u003cli data-section-id=\"e2s6kv\" data-start=\"1927\" data-end=\"1964\"\u003eTemperature Rating: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zhnlg\" data-start=\"1971\" data-end=\"1994\"\u003eProduct Positioning\u003c\/h3\u003e\n\u003cul data-start=\"1995\" data-end=\"2099\"\u003e\n\u003cli data-section-id=\"z23u8p\" data-start=\"1995\" data-end=\"2054\"\u003eApplication: Industrial \/ Commercial power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"cl0h9f\" data-start=\"2055\" data-end=\"2099\"\u003eReplacement Reference: Legacy HHED63B025\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48480417710329,"sku":"3VA41256ED340AA0","price":473.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA4111-5ED34-0AA0-All-New-1_a6b0431b-212d-4651-86a0-2bc4eca8a46b.webp?v=1780507434","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va4125-6ed34-0aa0-25a-3p-molded-case-circuit-breaker-panel-mount-480v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}