{"product_id":"siemens-3va4135-4ed14-0aa0-35a-3p-molded-case-circuit-breaker-bolt-on-480v-ac","title":"Siemens 3VA4135-4ED14-0AA0 35A 3P Molded Case Circuit Breaker – Bolt-On – 480V AC","description":"\u003cp data-start=\"90\" data-end=\"523\"\u003eThe Siemens 3VA4135-4ED14-0AA0 molded case circuit breaker is part of the Siemens 3VA4 series, designed for reliable industrial and commercial power distribution. It provides dependable overcurrent protection using a fixed thermal-magnetic trip unit with LI (long-time and instantaneous) functionality. Built for panelboard applications, it delivers strong performance, safety, and compliance with international electrical standards.\u003c\/p\u003e\n\u003cp data-start=\"525\" data-end=\"730\"\u003eThis breaker is engineered for Siemens P1 panelboards and similar distribution systems, offering compact installation, high interrupting capability, and flexible accessory options for system customization.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"737\" data-end=\"759\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"760\" data-end=\"1077\"\u003e\n\u003cli data-section-id=\"1flh7x7\" data-start=\"760\" data-end=\"783\"\u003eCurrent Rating: 35A\u003c\/li\u003e\n\u003cli data-section-id=\"mwlhud\" data-start=\"784\" data-end=\"811\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1rjhj1o\" data-start=\"812\" data-end=\"830\"\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"fnndbo\" data-start=\"831\" data-end=\"930\"\u003eVoltage Rating:\n\u003cul data-start=\"853\" data-end=\"930\"\u003e\n\u003cli data-section-id=\"1rnghoq\" data-start=\"853\" data-end=\"864\"\u003e240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1q4ufd0\" data-start=\"867\" data-end=\"883\"\u003e480Y\/277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1g4cuio\" data-start=\"886\" data-end=\"897\"\u003e480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"fup12k\" data-start=\"900\" data-end=\"916\"\u003e600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"22jbke\" data-start=\"919\" data-end=\"930\"\u003e250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dmn0m9\" data-start=\"931\" data-end=\"1077\"\u003eInterrupting Capacity:\n\u003cul data-start=\"960\" data-end=\"1077\"\u003e\n\u003cli data-section-id=\"2941hp\" data-start=\"960\" data-end=\"979\"\u003e85 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1fobm4o\" data-start=\"982\" data-end=\"1006\"\u003e35 kA @ 480Y\/277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"13hbuks\" data-start=\"1009\" data-end=\"1028\"\u003e35 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1lg7lb\" data-start=\"1031\" data-end=\"1055\"\u003e18 kA @ 600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"p5yocp\" data-start=\"1058\" data-end=\"1077\"\u003e85 kA @ 250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"152tit7\" data-start=\"1084\" data-end=\"1114\"\u003eTrip \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"1115\" data-end=\"1329\"\u003e\n\u003cli data-section-id=\"2puffi\" data-start=\"1115\" data-end=\"1152\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1153\" data-end=\"1179\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"5nai79\" data-start=\"1180\" data-end=\"1226\"\u003eProtection Type: Long-Time \u0026amp; Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"h6pbl8\" data-start=\"1227\" data-end=\"1283\"\u003eTrip Adjustability: Fixed thermal and fixed magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"35b0qr\" data-start=\"1284\" data-end=\"1303\"\u003eHACR Rated: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"10175cx\" data-start=\"1304\" data-end=\"1329\"\u003eCurrent Limiting: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1336\" data-end=\"1358\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1359\" data-end=\"1631\"\u003e\n\u003cli data-section-id=\"cazvjn\" data-start=\"1359\" data-end=\"1383\"\u003eSeries: Siemens 3VA4\u003c\/li\u003e\n\u003cli data-section-id=\"1marceb\" data-start=\"1384\" data-end=\"1402\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"psyc29\" data-start=\"1403\" data-end=\"1430\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"8duzif\" data-start=\"1431\" data-end=\"1480\"\u003eTerminal Type: Lugs (Load-side lugs included)\u003c\/li\u003e\n\u003cli data-section-id=\"13reef0\" data-start=\"1481\" data-end=\"1521\"\u003eFor Use With: Siemens P1 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"37s576\" data-start=\"1522\" data-end=\"1631\"\u003eAccessories Options: Shunt trip, auxiliary switch, undervoltage release, alarm switch, padlock attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1mr9dyg\" data-start=\"1638\" data-end=\"1656\"\u003eWiring Details\u003c\/h3\u003e\n\u003cul data-start=\"1657\" data-end=\"1746\"\u003e\n\u003cli data-section-id=\"inwryi\" data-start=\"1657\" data-end=\"1687\"\u003eWire Gauge Range: 14–8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"19thhsv\" data-start=\"1688\" data-end=\"1716\"\u003eMaximum Wire Size: 8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1j655zw\" data-start=\"1717\" data-end=\"1746\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"1753\" data-end=\"1778\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1779\" data-end=\"1908\"\u003e\n\u003cli data-section-id=\"6d8czo\" data-start=\"1779\" data-end=\"1789\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1pw3smc\" data-start=\"1790\" data-end=\"1805\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"12xbscc\" data-start=\"1806\" data-end=\"1825\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"j6meb1\" data-start=\"1826\" data-end=\"1850\"\u003eCE, CSA, UL Approved\u003c\/li\u003e\n\u003cli data-section-id=\"e2s6kv\" data-start=\"1851\" data-end=\"1888\"\u003eTemperature Rating: -25°C to 70°C\u003c\/li\u003e\n\u003cli data-section-id=\"35b0qr\" data-start=\"1889\" data-end=\"1908\"\u003eHACR Rated: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"34w9r0\" data-start=\"1915\" data-end=\"1930\"\u003eApplication\u003c\/h3\u003e\n\u003cul data-start=\"1931\" data-end=\"2084\"\u003e\n\u003cli data-section-id=\"1e7spqs\" data-start=\"1931\" data-end=\"1981\"\u003eIndustrial and commercial distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"tcpj8b\" data-start=\"1982\" data-end=\"2028\"\u003ePanelboard protection (Siemens P1 systems)\u003c\/li\u003e\n\u003cli data-section-id=\"1a0y3ps\" data-start=\"2029\" data-end=\"2084\"\u003eGeneral overcurrent protection for 3-phase circuits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48480532660473,"sku":"3VA4135-5ED34-0AA0","price":352.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA4111-5ED34-0AA0-All-New-1_6fcd1e70-11ec-49b4-a252-f6eccb37dadb.webp?v=1780510910","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va4135-4ed14-0aa0-35a-3p-molded-case-circuit-breaker-bolt-on-480v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}