{"product_id":"siemens-3va4150-5ed14-0aa0-50a-1p-molded-case-circuit-breaker-bolt-on-120-277v-ac","title":"Siemens 3VA4150-5ED14-0AA0 50A 1P Molded Case Circuit Breaker – Bolt-On – 120\/277V AC","description":"\u003cp data-start=\"96\" data-end=\"456\"\u003eThe Siemens 3VA4150-5ED14-0AA0 is a 50A, 1-pole molded case circuit breaker (MCCB) from the SENTRON 3VA4 series, designed for commercial and industrial power distribution applications. It features a fixed thermal-magnetic trip unit with LI (Long-Time and Instantaneous) protection, providing dependable overcurrent protection and reliable circuit interruption.\u003c\/p\u003e\n\u003cp data-start=\"458\" data-end=\"757\"\u003eEngineered for installation in Siemens P1, P2, and P3 panelboards and switchboards, this bolt-on breaker serves as a direct replacement for the legacy HED41B050 breaker. With Class M breaking capacity and current-limiting performance, it is well suited for demanding electrical distribution systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"764\" data-end=\"786\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"787\" data-end=\"1027\"\u003e\n\u003cli data-section-id=\"iklkt2\" data-start=\"787\" data-end=\"812\"\u003eCurrent Rating: 50 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"w5i29y\" data-start=\"813\" data-end=\"879\"\u003eVoltage Ratings:\n\u003cul data-start=\"834\" data-end=\"879\"\u003e\n\u003cli data-section-id=\"opqo27\" data-start=\"834\" data-end=\"843\"\u003e120 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ib78mm\" data-start=\"846\" data-end=\"855\"\u003e277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ot84hb\" data-start=\"858\" data-end=\"867\"\u003e125 VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1wmo3nw\" data-start=\"870\" data-end=\"879\"\u003e347 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4ej2hj\" data-start=\"880\" data-end=\"905\"\u003eNumber of Poles: 1-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1fv4asu\" data-start=\"906\" data-end=\"922\"\u003ePhase: 1-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"5cnwzw\" data-start=\"923\" data-end=\"1027\"\u003eInterrupting Capacity:\n\u003cul data-start=\"950\" data-end=\"1027\"\u003e\n\u003cli data-section-id=\"18xq4p4\" data-start=\"950\" data-end=\"967\"\u003e85 kA @ 120 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"8rpbhe\" data-start=\"970\" data-end=\"987\"\u003e35 kA @ 277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"18u8up4\" data-start=\"990\" data-end=\"1007\"\u003e85 kA @ 125 VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1angz1r\" data-start=\"1010\" data-end=\"1027\"\u003e18 kA @ 347 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"152tit7\" data-start=\"1034\" data-end=\"1064\"\u003eTrip \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"1065\" data-end=\"1332\"\u003e\n\u003cli data-section-id=\"gc0l3n\" data-start=\"1065\" data-end=\"1100\"\u003eTrip Technology: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1oc74iv\" data-start=\"1101\" data-end=\"1125\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"c1exnu\" data-start=\"1126\" data-end=\"1203\"\u003eProtection Functions:\n\u003cul data-start=\"1152\" data-end=\"1203\"\u003e\n\u003cli data-section-id=\"9gtck9\" data-start=\"1152\" data-end=\"1174\"\u003eLong-Time Protection\u003c\/li\u003e\n\u003cli data-section-id=\"d4prg3\" data-start=\"1177\" data-end=\"1203\"\u003eInstantaneous Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e3r6ef\" data-start=\"1204\" data-end=\"1262\"\u003eTrip Adjustability:\n\u003cul data-start=\"1228\" data-end=\"1262\"\u003e\n\u003cli data-section-id=\"1st96t1\" data-start=\"1228\" data-end=\"1243\"\u003eFixed Thermal\u003c\/li\u003e\n\u003cli data-section-id=\"1oz39gg\" data-start=\"1246\" data-end=\"1262\"\u003eFixed Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hdskf5\" data-start=\"1263\" data-end=\"1286\"\u003eCurrent Limiting: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1qonmdf\" data-start=\"1287\" data-end=\"1304\"\u003eHACR Rated: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"ho17af\" data-start=\"1305\" data-end=\"1332\"\u003eReverse Feed Capable: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1339\" data-end=\"1361\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1362\" data-end=\"1551\"\u003e\n\u003cli data-section-id=\"e9thxf\" data-start=\"1362\" data-end=\"1378\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"b1vr15\" data-start=\"1379\" data-end=\"1393\"\u003eSeries: 3VA4\u003c\/li\u003e\n\u003cli data-section-id=\"1eyqpht\" data-start=\"1394\" data-end=\"1419\"\u003eMounting Style: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1aboq6b\" data-start=\"1420\" data-end=\"1441\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"1fe4w0s\" data-start=\"1442\" data-end=\"1480\"\u003eAccessories Included: Load Side Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"1ikyexm\" data-start=\"1481\" data-end=\"1509\"\u003eBreaking Capacity Class: M\u003c\/li\u003e\n\u003cli data-section-id=\"16r1xzh\" data-start=\"1510\" data-end=\"1551\"\u003eReplacement For: HED41B050 (HED4 Frame)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1558\" data-end=\"1575\"\u003eCompatibility\u003c\/h3\u003e\n\u003cul data-start=\"1576\" data-end=\"1673\"\u003e\n\u003cli data-section-id=\"vzkpq4\" data-start=\"1576\" data-end=\"1600\"\u003eSiemens P1 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1qk8e7z\" data-start=\"1601\" data-end=\"1625\"\u003eSiemens P2 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"oa1rum\" data-start=\"1626\" data-end=\"1650\"\u003eSiemens P3 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1i31lyx\" data-start=\"1651\" data-end=\"1673\"\u003eSiemens Switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1mr9dyg\" data-start=\"1680\" data-end=\"1698\"\u003eWiring Details\u003c\/h3\u003e\n\u003cul data-start=\"1699\" data-end=\"1798\"\u003e\n\u003cli data-section-id=\"h1fu1z\" data-start=\"1699\" data-end=\"1742\"\u003eWire Gauge Range: 8 AWG – 3\/0 AWG (Cu\/Al)\u003c\/li\u003e\n\u003cli data-section-id=\"12u4vsx\" data-start=\"1743\" data-end=\"1769\"\u003eMinimum Wire Size: 8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"s6cpgr\" data-start=\"1770\" data-end=\"1798\"\u003eMaximum Wire Size: 3\/0 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1sywupl\" data-start=\"1805\" data-end=\"1830\"\u003eAvailable Accessories\u003c\/h3\u003e\n\u003cul data-start=\"1831\" data-end=\"1916\"\u003e\n\u003cli data-section-id=\"k9qb9f\" data-start=\"1831\" data-end=\"1843\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"151kr8w\" data-start=\"1844\" data-end=\"1862\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"17r2sbv\" data-start=\"1863\" data-end=\"1885\"\u003eUndervoltage Release\u003c\/li\u003e\n\u003cli data-section-id=\"1g5m8h5\" data-start=\"1886\" data-end=\"1900\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"170brvl\" data-start=\"1901\" data-end=\"1916\"\u003eRotary Handle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"1923\" data-end=\"1948\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1949\" data-end=\"2081\"\u003e\n\u003cli data-section-id=\"99n7pg\" data-start=\"1949\" data-end=\"1957\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1wa6t2c\" data-start=\"1958\" data-end=\"1971\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11qi724\" data-start=\"1972\" data-end=\"1989\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1vrrx45\" data-start=\"1990\" data-end=\"2003\"\u003eCE Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1a6fkpe\" data-start=\"2004\" data-end=\"2018\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"87nvu7\" data-start=\"2019\" data-end=\"2033\"\u003eNOM Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1qadegi\" data-start=\"2034\" data-end=\"2045\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1miqjf3\" data-start=\"2046\" data-end=\"2081\"\u003eTemperature Rating: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"xldzoc\" data-start=\"2088\" data-end=\"2113\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"2114\" data-end=\"2178\"\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"2114\" data-end=\"2126\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"7exc1y\" data-start=\"2127\" data-end=\"2152\"\u003eCurrent Limiting Design\u003c\/li\u003e\n\u003cli data-section-id=\"17snaca\" data-start=\"2153\" data-end=\"2178\"\u003eReverse Feed Capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2185\" data-end=\"2201\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2202\" data-end=\"2390\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"gbqagh\" data-start=\"2202\" data-end=\"2233\"\u003eCommercial power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"17cr8dz\" data-start=\"2234\" data-end=\"2265\"\u003eIndustrial electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"1eqqtcc\" data-start=\"2266\" data-end=\"2293\"\u003eBranch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1d4ae3s\" data-start=\"2294\" data-end=\"2336\"\u003ePanelboard and switchboard installations\u003c\/li\u003e\n\u003cli data-section-id=\"a07gwy\" data-start=\"2337\" data-end=\"2390\" data-is-last-node=\"\"\u003eRetrofit replacement for Siemens HED41B050 breakers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48480835666169,"sku":"3VA4150-5ED14-0AA0","price":208.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA4150-5ED14-0AA0-1-Pole-Circuit-Breaker_Siemens_1.webp?v=1780523795","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va4150-5ed14-0aa0-50a-1p-molded-case-circuit-breaker-bolt-on-120-277v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}