{"product_id":"siemens-3va4160-5ed34-0aa0-60a-3p-molded-case-circuit-breaker-bolt-on-480v-ac","title":"Siemens 3VA4160-5ED34-0AA0 60A 3P Molded Case Circuit Breaker – Bolt-On – 480V AC","description":"\u003cp data-start=\"92\" data-end=\"445\"\u003eThe Siemens 3VA4160-5ED34-0AA0 is a 3-pole, 60A molded case circuit breaker from the SENTRON 3VA4 family, engineered for commercial and industrial low-voltage power distribution systems. Equipped with a TM210 thermal-magnetic trip unit, it provides dependable overload and short-circuit protection through fixed thermal and fixed magnetic trip settings.\u003c\/p\u003e\n\u003cp data-start=\"447\" data-end=\"728\"\u003eBuilt on the 3VA41 frame with Medium (Class M) breaking capacity, this breaker delivers interrupting ratings of 35kA at 480V AC and 18kA at 600Y\/347V AC. Factory-installed load-side lugs simplify installation, making it a reliable solution for feeder and branch circuit protection.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"735\" data-end=\"757\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"758\" data-end=\"962\"\u003e\n\u003cli data-section-id=\"a8woph\" data-start=\"758\" data-end=\"783\"\u003eCurrent Rating: 60 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"95w6f3\" data-start=\"784\" data-end=\"809\"\u003eVoltage Rating: 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"5p1llh\" data-start=\"810\" data-end=\"835\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"ycv276\" data-start=\"836\" data-end=\"905\"\u003eInterrupting Capacity:\n\u003cul data-start=\"863\" data-end=\"905\"\u003e\n\u003cli data-section-id=\"tsi7v0\" data-start=\"863\" data-end=\"880\"\u003e35 kA @ 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1a6uyr3\" data-start=\"883\" data-end=\"905\"\u003e18 kA @ 600Y\/347V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mj2kpb\" data-start=\"906\" data-end=\"933\"\u003eAIC Rating: 100 kA @ 480V\u003c\/li\u003e\n\u003cli data-section-id=\"1ikyexm\" data-start=\"934\" data-end=\"962\"\u003eBreaking Capacity Class: M\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"152tit7\" data-start=\"969\" data-end=\"999\"\u003eTrip \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"1000\" data-end=\"1212\"\u003e\n\u003cli data-section-id=\"1vh5gzl\" data-start=\"1000\" data-end=\"1018\"\u003eTrip Unit: TM210\u003c\/li\u003e\n\u003cli data-section-id=\"54mr9t\" data-start=\"1019\" data-end=\"1054\"\u003eProtection Type: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"r31kem\" data-start=\"1055\" data-end=\"1108\"\u003eTrip Function: Fixed Thermal, Fixed Magnetic (FTFM)\u003c\/li\u003e\n\u003cli data-section-id=\"doozit\" data-start=\"1109\" data-end=\"1142\"\u003eOverload Protection (Ir): Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"bc4x6\" data-start=\"1143\" data-end=\"1181\"\u003eShort-Circuit Protection (Ii): Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"19ua99h\" data-start=\"1182\" data-end=\"1212\"\u003eApplication: Line Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1219\" data-end=\"1241\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1242\" data-end=\"1443\"\u003e\n\u003cli data-section-id=\"e9thxf\" data-start=\"1242\" data-end=\"1258\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"nkj6yo\" data-start=\"1259\" data-end=\"1272\"\u003eFamily: 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"b1vr15\" data-start=\"1273\" data-end=\"1287\"\u003eSeries: 3VA4\u003c\/li\u003e\n\u003cli data-section-id=\"1ns71ci\" data-start=\"1288\" data-end=\"1321\"\u003ePart Number: 3VA4160-5ED34-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"z7zfom\" data-start=\"1322\" data-end=\"1361\"\u003eCategory: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"4iczri\" data-start=\"1362\" data-end=\"1376\"\u003eFrame: 3VA41\u003c\/li\u003e\n\u003cli data-section-id=\"gsd6kz\" data-start=\"1377\" data-end=\"1418\"\u003eTerminal Type: Load-Side Lugs Installed\u003c\/li\u003e\n\u003cli data-section-id=\"av5m2m\" data-start=\"1419\" data-end=\"1443\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"p3m70j\" data-start=\"1450\" data-end=\"1480\"\u003eStandards \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul data-start=\"1481\" data-end=\"1495\"\u003e\n\u003cli data-section-id=\"1a6fkpe\" data-start=\"1481\" data-end=\"1495\"\u003eCSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ctooql\" data-start=\"1502\" data-end=\"1530\"\u003ePhysical Characteristics\u003c\/h3\u003e\n\u003cul data-start=\"1531\" data-end=\"1592\"\u003e\n\u003cli data-section-id=\"ar2yzf\" data-start=\"1531\" data-end=\"1573\"\u003eDimensions (W × H × D): 3 × 5.5 × 3.7 in\u003c\/li\u003e\n\u003cli data-section-id=\"m3kd4u\" data-start=\"1574\" data-end=\"1592\"\u003eWeight: 1.638 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"1599\" data-end=\"1615\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1616\" data-end=\"1897\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"gbqagh\" data-start=\"1616\" data-end=\"1647\"\u003eCommercial power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"17cr8dz\" data-start=\"1648\" data-end=\"1679\"\u003eIndustrial electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"183paq\" data-start=\"1680\" data-end=\"1711\"\u003eThree-phase feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"1eqqtcc\" data-start=\"1712\" data-end=\"1739\"\u003eBranch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1d4ae3s\" data-start=\"1740\" data-end=\"1782\"\u003ePanelboard and switchboard installations\u003c\/li\u003e\n\u003cli data-section-id=\"1rn2k2\" data-start=\"1783\" data-end=\"1897\" data-is-last-node=\"\"\u003eLow-voltage distribution networks requiring thermal-magnetic protection and medium breaking capacity performance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48485152653561,"sku":"3VA4160-5ED34-0AA0","price":352.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA4111-5ED34-0AA0-All-New-1_cf6053bd-b3ac-4083-9239-9871dc759bde.webp?v=1780574367","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va4160-5ed34-0aa0-60a-3p-molded-case-circuit-breaker-bolt-on-480v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}