{"product_id":"siemens-3va4180-6ed24-0aa0-80a-2p-molded-case-circuit-breaker-panel-mount-240-480v-ac","title":"Siemens 3VA4180-6ED24-0AA0 80A 2P Molded Case Circuit Breaker – Panel Mount – 240\/480V AC","description":"\u003cp data-start=\"100\" data-end=\"454\"\u003eThe Siemens 3VA4180-6ED24-0AA0 is an 80A, 2-pole molded case circuit breaker from the SENTRON 3VA4 series, designed for commercial and industrial electrical distribution systems. It features a TM210 thermal-magnetic trip unit with fixed thermal and fixed magnetic (FTFM) protection, delivering reliable long-time and instantaneous overcurrent protection.\u003c\/p\u003e\n\u003cp data-start=\"456\" data-end=\"742\"\u003eEngineered for installation in Siemens P1 through P5 panelboards and switchboards, this breaker serves as a direct replacement for legacy ED62B080 models. With a high interrupting capacity and HACR-rated construction, it is suitable for demanding branch and feeder circuit applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"749\" data-end=\"771\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"772\" data-end=\"1066\"\u003e\n\u003cli data-section-id=\"o8ftln\" data-start=\"772\" data-end=\"797\"\u003eCurrent Rating: 80 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"j0t8lj\" data-start=\"798\" data-end=\"886\"\u003eVoltage Ratings:\n\u003cul data-start=\"819\" data-end=\"886\"\u003e\n\u003cli data-section-id=\"hssmq2\" data-start=\"819\" data-end=\"828\"\u003e240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"15ern7o\" data-start=\"831\" data-end=\"845\"\u003e480Y\/277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gr0eps\" data-start=\"848\" data-end=\"857\"\u003e480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1i0rwdo\" data-start=\"860\" data-end=\"874\"\u003e600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"jp7bny\" data-start=\"877\" data-end=\"886\"\u003e250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"54lx10\" data-start=\"887\" data-end=\"912\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1fv4asu\" data-start=\"913\" data-end=\"929\"\u003ePhase: 1-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1tbmp7z\" data-start=\"930\" data-end=\"1066\"\u003eInterrupting Capacity:\n\u003cul data-start=\"957\" data-end=\"1066\"\u003e\n\u003cli data-section-id=\"2klx81\" data-start=\"957\" data-end=\"975\"\u003e100 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1mfc2el\" data-start=\"978\" data-end=\"1000\"\u003e65 kA @ 480Y\/277 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"tybv2h\" data-start=\"1003\" data-end=\"1020\"\u003e65 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"dtav29\" data-start=\"1023\" data-end=\"1045\"\u003e25 kA @ 600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"o19dh\" data-start=\"1048\" data-end=\"1066\"\u003e100 kA @ 250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"152tit7\" data-start=\"1073\" data-end=\"1103\"\u003eTrip \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"1104\" data-end=\"1347\"\u003e\n\u003cli data-section-id=\"gc0l3n\" data-start=\"1104\" data-end=\"1139\"\u003eTrip Technology: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1oc74iv\" data-start=\"1140\" data-end=\"1164\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"c1exnu\" data-start=\"1165\" data-end=\"1242\"\u003eProtection Functions:\n\u003cul data-start=\"1191\" data-end=\"1242\"\u003e\n\u003cli data-section-id=\"9gtck9\" data-start=\"1191\" data-end=\"1213\"\u003eLong-Time Protection\u003c\/li\u003e\n\u003cli data-section-id=\"d4prg3\" data-start=\"1216\" data-end=\"1242\"\u003eInstantaneous Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e3r6ef\" data-start=\"1243\" data-end=\"1301\"\u003eTrip Adjustability:\n\u003cul data-start=\"1267\" data-end=\"1301\"\u003e\n\u003cli data-section-id=\"1st96t1\" data-start=\"1267\" data-end=\"1282\"\u003eFixed Thermal\u003c\/li\u003e\n\u003cli data-section-id=\"1oz39gg\" data-start=\"1285\" data-end=\"1301\"\u003eFixed Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qonmdf\" data-start=\"1302\" data-end=\"1319\"\u003eHACR Rated: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"ho17af\" data-start=\"1320\" data-end=\"1347\"\u003eReverse Feed Capable: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1354\" data-end=\"1376\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1377\" data-end=\"1534\"\u003e\n\u003cli data-section-id=\"e9thxf\" data-start=\"1377\" data-end=\"1393\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"b1vr15\" data-start=\"1394\" data-end=\"1408\"\u003eSeries: 3VA4\u003c\/li\u003e\n\u003cli data-section-id=\"ko4gj\" data-start=\"1409\" data-end=\"1424\"\u003eAmperage: 80A\u003c\/li\u003e\n\u003cli data-section-id=\"1641neb\" data-start=\"1425\" data-end=\"1454\"\u003eMounting Style: Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1aboq6b\" data-start=\"1455\" data-end=\"1476\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"122xk04\" data-start=\"1477\" data-end=\"1506\"\u003eAccessories: Load Side Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"z2n954\" data-start=\"1507\" data-end=\"1534\"\u003eReplacement For: ED62B080\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1541\" data-end=\"1558\"\u003eCompatibility\u003c\/h3\u003e\n\u003cul data-start=\"1559\" data-end=\"1706\"\u003e\n\u003cli data-section-id=\"vzkpq4\" data-start=\"1559\" data-end=\"1583\"\u003eSiemens P1 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1qk8e7z\" data-start=\"1584\" data-end=\"1608\"\u003eSiemens P2 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"oa1rum\" data-start=\"1609\" data-end=\"1633\"\u003eSiemens P3 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"14eyneh\" data-start=\"1634\" data-end=\"1658\"\u003eSiemens P4 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"24s114\" data-start=\"1659\" data-end=\"1683\"\u003eSiemens P5 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1i31lyx\" data-start=\"1684\" data-end=\"1706\"\u003eSiemens Switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1mr9dyg\" data-start=\"1713\" data-end=\"1731\"\u003eWiring Details\u003c\/h3\u003e\n\u003cul data-start=\"1732\" data-end=\"1825\"\u003e\n\u003cli data-section-id=\"65of4f\" data-start=\"1732\" data-end=\"1768\"\u003eWire Gauge Range: 14 AWG – 3\/0 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"7f5uho\" data-start=\"1769\" data-end=\"1796\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"s6cpgr\" data-start=\"1797\" data-end=\"1825\"\u003eMaximum Wire Size: 3\/0 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1sywupl\" data-start=\"1832\" data-end=\"1857\"\u003eAvailable Accessories\u003c\/h3\u003e\n\u003cul data-start=\"1858\" data-end=\"1948\"\u003e\n\u003cli data-section-id=\"k9qb9f\" data-start=\"1858\" data-end=\"1870\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"151kr8w\" data-start=\"1871\" data-end=\"1889\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"17r2sbv\" data-start=\"1890\" data-end=\"1912\"\u003eUndervoltage Release\u003c\/li\u003e\n\u003cli data-section-id=\"1g5m8h5\" data-start=\"1913\" data-end=\"1927\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"dqp1fz\" data-start=\"1928\" data-end=\"1948\"\u003ePadlock Attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"1955\" data-end=\"1980\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1981\" data-end=\"2111\"\u003e\n\u003cli data-section-id=\"99n7pg\" data-start=\"1981\" data-end=\"1989\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1wa6t2c\" data-start=\"1990\" data-end=\"2003\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11qi724\" data-start=\"2004\" data-end=\"2021\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1vrrx45\" data-start=\"2022\" data-end=\"2035\"\u003eCE Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1a6fkpe\" data-start=\"2036\" data-end=\"2050\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1qadegi\" data-start=\"2051\" data-end=\"2062\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"2063\" data-end=\"2075\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1miqjf3\" data-start=\"2076\" data-end=\"2111\"\u003eTemperature Rating: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"xldzoc\" data-start=\"2118\" data-end=\"2143\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"2144\" data-end=\"2265\"\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"2144\" data-end=\"2156\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"17snaca\" data-start=\"2157\" data-end=\"2182\"\u003eReverse Feed Capability\u003c\/li\u003e\n\u003cli data-section-id=\"107lqef\" data-start=\"2183\" data-end=\"2218\"\u003eHigh Interrupting Capacity Design\u003c\/li\u003e\n\u003cli data-section-id=\"1p2tvho\" data-start=\"2219\" data-end=\"2265\"\u003eIndustrial-grade thermal-magnetic protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2272\" data-end=\"2288\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2289\" data-end=\"2476\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"433w68\" data-start=\"2289\" data-end=\"2325\"\u003eCommercial electrical distribution\u003c\/li\u003e\n\u003cli data-section-id=\"ghpwyu\" data-start=\"2326\" data-end=\"2352\"\u003eIndustrial power systems\u003c\/li\u003e\n\u003cli data-section-id=\"1eqqtcc\" data-start=\"2353\" data-end=\"2380\"\u003eBranch circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1d4ae3s\" data-start=\"2381\" data-end=\"2423\"\u003ePanelboard and switchboard installations\u003c\/li\u003e\n\u003cli data-section-id=\"j5387a\" data-start=\"2424\" data-end=\"2476\" data-is-last-node=\"\"\u003eRetrofit replacement for Siemens ED62B080 breakers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48485182767353,"sku":"3VA4180-6ED24-0AA0","price":495.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/G_I202_XX_53599i_8a382962-9a00-48b8-aeaa-a2e234a96098.jpg?v=1780576307","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va4180-6ed24-0aa0-80a-2p-molded-case-circuit-breaker-panel-mount-240-480v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}