{"product_id":"siemens-3va5110-4ec31-0aa0-100a-3p-molded-case-circuit-breaker-panel-mount-240-480v-ac","title":"Siemens 3VA5110-4EC31-0AA0 100A 3P Molded Case Circuit Breaker – Panel Mount – 240\/480V AC","description":"\u003cp data-start=\"101\" data-end=\"456\"\u003eThe Siemens 3VA5110-4EC31-0AA0 is a 100A, 3-pole molded case circuit breaker from the SENTRON 3VA5 series, designed for demanding industrial and commercial power distribution systems. It features a thermal-magnetic trip unit with fixed thermal and adjustable magnetic (LI) protection, enabling improved coordination for feeder and motor load applications.\u003c\/p\u003e\n\u003cp data-start=\"458\" data-end=\"756\"\u003eEngineered for Siemens P1, P2, P3, and 3VA panelboards, this breaker supports panel mount installation and is compatible with switchboard systems when paired with the appropriate accessories. It also serves as a replacement option for legacy ED63B100 breakers when used with suitable mounting kits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2p98c\" data-start=\"763\" data-end=\"785\"\u003eElectrical Ratings\u003c\/h3\u003e\n\u003cul data-start=\"786\" data-end=\"1037\"\u003e\n\u003cli data-section-id=\"alkc1u\" data-start=\"786\" data-end=\"812\"\u003eCurrent Rating: 100 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1boz5ri\" data-start=\"813\" data-end=\"884\"\u003eVoltage Ratings:\n\u003cul data-start=\"834\" data-end=\"884\"\u003e\n\u003cli data-section-id=\"hssmq2\" data-start=\"834\" data-end=\"843\"\u003e240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gr0eps\" data-start=\"846\" data-end=\"855\"\u003e480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1i0rwdo\" data-start=\"858\" data-end=\"872\"\u003e600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"11tqgfg\" data-start=\"875\" data-end=\"884\"\u003e500 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5p1llh\" data-start=\"885\" data-end=\"910\"\u003eNumber of Poles: 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"nh2u98\" data-start=\"911\" data-end=\"927\"\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"tezi99\" data-start=\"928\" data-end=\"1037\"\u003eInterrupting Capacity:\n\u003cul data-start=\"955\" data-end=\"1037\"\u003e\n\u003cli data-section-id=\"1jofekj\" data-start=\"955\" data-end=\"972\"\u003e65 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"mhck5p\" data-start=\"975\" data-end=\"992\"\u003e25 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"46mfdv\" data-start=\"995\" data-end=\"1017\"\u003e14 kA @ 600Y\/347 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"11emijl\" data-start=\"1020\" data-end=\"1037\"\u003e25 kA @ 500 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"152tit7\" data-start=\"1044\" data-end=\"1074\"\u003eTrip \u0026amp; Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"1075\" data-end=\"1323\"\u003e\n\u003cli data-section-id=\"gc0l3n\" data-start=\"1075\" data-end=\"1110\"\u003eTrip Technology: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1oc74iv\" data-start=\"1111\" data-end=\"1135\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"c1exnu\" data-start=\"1136\" data-end=\"1213\"\u003eProtection Functions:\n\u003cul data-start=\"1162\" data-end=\"1213\"\u003e\n\u003cli data-section-id=\"9gtck9\" data-start=\"1162\" data-end=\"1184\"\u003eLong-Time Protection\u003c\/li\u003e\n\u003cli data-section-id=\"d4prg3\" data-start=\"1187\" data-end=\"1213\"\u003eInstantaneous Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o2i5t2\" data-start=\"1214\" data-end=\"1277\"\u003eTrip Adjustability:\n\u003cul data-start=\"1238\" data-end=\"1277\"\u003e\n\u003cli data-section-id=\"1st96t1\" data-start=\"1238\" data-end=\"1253\"\u003eFixed Thermal\u003c\/li\u003e\n\u003cli data-section-id=\"i5laf5\" data-start=\"1256\" data-end=\"1277\"\u003eAdjustable Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qonmdf\" data-start=\"1278\" data-end=\"1295\"\u003eHACR Rated: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"ho17af\" data-start=\"1296\" data-end=\"1323\"\u003eReverse Feed Capable: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1330\" data-end=\"1352\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1353\" data-end=\"1582\"\u003e\n\u003cli data-section-id=\"e9thxf\" data-start=\"1353\" data-end=\"1369\"\u003eBrand: Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"b1vr14\" data-start=\"1370\" data-end=\"1384\"\u003eSeries: 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"5b5yk7\" data-start=\"1385\" data-end=\"1418\"\u003ePart Number: 3VA5110-4EC31-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"1641neb\" data-start=\"1419\" data-end=\"1448\"\u003eMounting Style: Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1aboq6b\" data-start=\"1449\" data-end=\"1470\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"mz6ybk\" data-start=\"1471\" data-end=\"1534\"\u003eAccessories: Not included (Lug kits and accessories optional)\u003c\/li\u003e\n\u003cli data-section-id=\"xkqc1k\" data-start=\"1535\" data-end=\"1582\"\u003eReplacement For: ED63B100 (with mounting kit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"purqi0\" data-start=\"1589\" data-end=\"1606\"\u003eCompatibility\u003c\/h3\u003e\n\u003cul data-start=\"1607\" data-end=\"1730\"\u003e\n\u003cli data-section-id=\"vzkpq4\" data-start=\"1607\" data-end=\"1631\"\u003eSiemens P1 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1qk8e7z\" data-start=\"1632\" data-end=\"1656\"\u003eSiemens P2 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"oa1rum\" data-start=\"1657\" data-end=\"1681\"\u003eSiemens P3 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"2i5do9\" data-start=\"1682\" data-end=\"1707\"\u003eSiemens 3VA Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1i31lyx\" data-start=\"1708\" data-end=\"1730\"\u003eSiemens Switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"131luvw\" data-start=\"1737\" data-end=\"1762\"\u003eStandards \u0026amp; Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1763\" data-end=\"1890\"\u003e\n\u003cli data-section-id=\"99n7pg\" data-start=\"1763\" data-end=\"1771\"\u003eUL 489\u003c\/li\u003e\n\u003cli data-section-id=\"1wa6t2c\" data-start=\"1772\" data-end=\"1785\"\u003eIEC 60947-2\u003c\/li\u003e\n\u003cli data-section-id=\"11qi724\" data-start=\"1786\" data-end=\"1803\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"1804\" data-end=\"1816\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1oljj3y\" data-start=\"1817\" data-end=\"1854\"\u003eCE, CSA, EAC, IEC, UL, VDE Approved\u003c\/li\u003e\n\u003cli data-section-id=\"1miqjf3\" data-start=\"1855\" data-end=\"1890\"\u003eTemperature Rating: -25°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"xldzoc\" data-start=\"1897\" data-end=\"1922\"\u003eConstruction Features\u003c\/h3\u003e\n\u003cul data-start=\"1923\" data-end=\"2033\"\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"1923\" data-end=\"1935\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"17snaca\" data-start=\"1936\" data-end=\"1961\"\u003eReverse Feed Capability\u003c\/li\u003e\n\u003cli data-section-id=\"164on22\" data-start=\"1962\" data-end=\"1998\"\u003eMotor load coordination capability\u003c\/li\u003e\n\u003cli data-section-id=\"11wsmvi\" data-start=\"1999\" data-end=\"2033\"\u003eModular accessory system support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2040\" data-end=\"2056\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2057\" data-end=\"2258\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"5irm6i\" data-start=\"2057\" data-end=\"2088\"\u003eIndustrial power distribution\u003c\/li\u003e\n\u003cli data-section-id=\"ipv5we\" data-start=\"2089\" data-end=\"2128\"\u003eCommercial feeder and branch circuits\u003c\/li\u003e\n\u003cli data-section-id=\"7ajiep\" data-start=\"2129\" data-end=\"2161\"\u003eMotor and HVAC load protection\u003c\/li\u003e\n\u003cli data-section-id=\"1d4ae3s\" data-start=\"2162\" data-end=\"2204\"\u003ePanelboard and switchboard installations\u003c\/li\u003e\n\u003cli data-section-id=\"1b05e8n\" data-start=\"2205\" data-end=\"2258\" data-is-last-node=\"\"\u003eRetrofit replacement applications (ED63B100 series)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48485983944953,"sku":"3VA5110-4EC31-0AA0","price":544.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5110-4EC31-0AA0-3-Pole-Circuit-Breaker_Siemens-1_8b5acf75-07a8-4790-8f20-36a5af4102cf.webp?v=1780585438","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5110-4ec31-0aa0-100a-3p-molded-case-circuit-breaker-panel-mount-240-480v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}