{"product_id":"siemens-3va5130-6ed31-0aa0-30-amp-3-pole-molded-case-circuit-breaker-feed-thru-mount-600v-ac","title":"Siemens 3VA5130-6ED31-0AA0 30 Amp 3-Pole Molded Case Circuit Breaker – Feed-Thru Mount – 600V AC","description":"\u003cp data-start=\"122\" data-end=\"869\"\u003eThe Siemens 3VA5130-6ED31-0AA0 is a high-performance molded case circuit breaker engineered for commercial and industrial power distribution applications requiring superior fault interruption capability. Part of the Siemens 3VA51 frame series, this 3-pole, 30A breaker features a TM210 thermal-magnetic trip unit with fixed long-time (Ir) and instantaneous (Ii) protection settings, ensuring dependable overload and short-circuit protection. Designed with a High (Class H) breaking capacity, it provides interrupting ratings of 65kA at 480VAC and 25kA at 600Y\/347VAC. The breaker is supplied without lugs and utilizes a feed-thru connection configuration, making it suitable for a wide range of low-voltage distribution systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"871\" data-end=\"893\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"894\" data-end=\"1064\"\u003e\n\u003cli data-section-id=\"f4ozdc\" data-start=\"894\" data-end=\"923\"\u003e\n\u003cstrong data-start=\"896\" data-end=\"915\"\u003eCurrent Rating:\u003c\/strong\u003e 30 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"199e4lt\" data-start=\"924\" data-end=\"958\"\u003e\n\u003cstrong data-start=\"926\" data-end=\"945\"\u003eVoltage Rating:\u003c\/strong\u003e 600 Volts AC\u003c\/li\u003e\n\u003cli data-section-id=\"1murovg\" data-start=\"959\" data-end=\"979\"\u003e\n\u003cstrong data-start=\"961\" data-end=\"971\"\u003ePhase:\u003c\/strong\u003e 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1k2j0h4\" data-start=\"980\" data-end=\"1005\"\u003e\n\u003cstrong data-start=\"982\" data-end=\"996\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"z9ppme\" data-start=\"1006\" data-end=\"1064\"\u003e\n\u003cstrong data-start=\"1008\" data-end=\"1023\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1026\" data-end=\"1064\"\u003e\n\u003cli data-section-id=\"jd9qfd\" data-start=\"1026\" data-end=\"1041\"\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"wqlh6p\" data-start=\"1044\" data-end=\"1064\"\u003e25kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1066\" data-end=\"1088\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1089\" data-end=\"1520\"\u003e\n\u003cli data-section-id=\"13z4f0o\" data-start=\"1089\" data-end=\"1143\"\u003e\n\u003cstrong data-start=\"1091\" data-end=\"1108\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"jfonqh\" data-start=\"1144\" data-end=\"1163\"\u003e\n\u003cstrong data-start=\"1146\" data-end=\"1157\"\u003eSeries:\u003c\/strong\u003e 3VA51\u003c\/li\u003e\n\u003cli data-section-id=\"7o3gqo\" data-start=\"1164\" data-end=\"1181\"\u003e\n\u003cstrong data-start=\"1166\" data-end=\"1177\"\u003eFamily:\u003c\/strong\u003e 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"1b7sbdh\" data-start=\"1182\" data-end=\"1211\"\u003e\n\u003cstrong data-start=\"1184\" data-end=\"1204\"\u003eNumber of Poles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1ecruw8\" data-start=\"1212\" data-end=\"1244\"\u003e\n\u003cstrong data-start=\"1214\" data-end=\"1234\"\u003eConnection Type:\u003c\/strong\u003e Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"7qrkvx\" data-start=\"1245\" data-end=\"1267\"\u003e\n\u003cstrong data-start=\"1247\" data-end=\"1262\"\u003eFrame Size:\u003c\/strong\u003e 125A\u003c\/li\u003e\n\u003cli data-section-id=\"fpvaq1\" data-start=\"1268\" data-end=\"1288\"\u003e\n\u003cstrong data-start=\"1270\" data-end=\"1284\"\u003eFunctions:\u003c\/strong\u003e NGC\u003c\/li\u003e\n\u003cli data-section-id=\"1hbpbh8\" data-start=\"1289\" data-end=\"1328\"\u003e\n\u003cstrong data-start=\"1291\" data-end=\"1311\"\u003eProtection Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"jgelz4\" data-start=\"1329\" data-end=\"1378\"\u003e\n\u003cstrong data-start=\"1331\" data-end=\"1345\"\u003eTrip Unit:\u003c\/strong\u003e TM210 Thermal-Magnetic Trip Unit\u003c\/li\u003e\n\u003cli data-section-id=\"16robjh\" data-start=\"1379\" data-end=\"1438\"\u003e\n\u003cstrong data-start=\"1381\" data-end=\"1399\"\u003eTrip Function:\u003c\/strong\u003e Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"7yzg85\" data-start=\"1439\" data-end=\"1483\"\u003e\n\u003cstrong data-start=\"1441\" data-end=\"1464\"\u003eTrip Adjustability:\u003c\/strong\u003e Fixed Ir, Fixed Ii\u003c\/li\u003e\n\u003cli data-section-id=\"1249h5h\" data-start=\"1484\" data-end=\"1520\"\u003e\n\u003cstrong data-start=\"1486\" data-end=\"1507\"\u003eSpecial Features:\u003c\/strong\u003e Without Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1522\" data-end=\"1550\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1551\" data-end=\"1772\"\u003e\n\u003cli data-section-id=\"tlvm1q\" data-start=\"1551\" data-end=\"1596\"\u003e\n\u003cstrong data-start=\"1553\" data-end=\"1581\"\u003eBreaking Capacity Class:\u003c\/strong\u003e High (Class H)\u003c\/li\u003e\n\u003cli data-section-id=\"dwpz3u\" data-start=\"1597\" data-end=\"1661\"\u003e\n\u003cstrong data-start=\"1599\" data-end=\"1623\"\u003eProtection Features:\u003c\/strong\u003e Overload and Short-Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"yf2079\" data-start=\"1662\" data-end=\"1708\"\u003e\n\u003cstrong data-start=\"1664\" data-end=\"1681\"\u003eConstruction:\u003c\/strong\u003e Compact Molded Case Design\u003c\/li\u003e\n\u003cli data-section-id=\"1k7miyl\" data-start=\"1709\" data-end=\"1772\"\u003e\n\u003cstrong data-start=\"1711\" data-end=\"1727\"\u003eApplication:\u003c\/strong\u003e Commercial and Industrial Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1774\" data-end=\"1801\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1802\" data-end=\"1835\"\u003e\n\u003cli data-section-id=\"19vv1m8\" data-start=\"1802\" data-end=\"1835\"\u003e\n\u003cstrong data-start=\"1804\" data-end=\"1822\"\u003eCertification:\u003c\/strong\u003e CSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1837\" data-end=\"1853\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1854\" data-end=\"1943\"\u003e\n\u003cli data-section-id=\"oxyyvs\" data-start=\"1854\" data-end=\"1887\"\u003e\n\u003cstrong data-start=\"1856\" data-end=\"1873\"\u003eManufacturer:\u003c\/strong\u003e Siemens \/ ITE\u003c\/li\u003e\n\u003cli data-section-id=\"vnz5u8\" data-start=\"1888\" data-end=\"1925\"\u003e\n\u003cstrong data-start=\"1890\" data-end=\"1906\"\u003ePart Number:\u003c\/strong\u003e 3VA5130-6ED31-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"7o3gqo\" data-start=\"1926\" data-end=\"1943\"\u003e\n\u003cstrong data-start=\"1928\" data-end=\"1939\"\u003eFamily:\u003c\/strong\u003e 3VA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ddop7y\" data-start=\"1945\" data-end=\"1970\"\u003eDimensions and Weight\u003c\/h3\u003e\n\u003cul data-start=\"1971\" data-end=\"2055\"\u003e\n\u003cli data-section-id=\"9v2k5g\" data-start=\"1971\" data-end=\"1991\"\u003e\n\u003cstrong data-start=\"1973\" data-end=\"1984\"\u003eHeight:\u003c\/strong\u003e 5.5 in\u003c\/li\u003e\n\u003cli data-section-id=\"1wco6ji\" data-start=\"1992\" data-end=\"2011\"\u003e\n\u003cstrong data-start=\"1994\" data-end=\"2004\"\u003eWidth:\u003c\/strong\u003e 3.0 in\u003c\/li\u003e\n\u003cli data-section-id=\"19b1a2a\" data-start=\"2012\" data-end=\"2031\"\u003e\n\u003cstrong data-start=\"2014\" data-end=\"2024\"\u003eDepth:\u003c\/strong\u003e 3.7 in\u003c\/li\u003e\n\u003cli data-section-id=\"17400ee\" data-start=\"2032\" data-end=\"2055\"\u003e\n\u003cstrong data-start=\"2034\" data-end=\"2045\"\u003eWeight:\u003c\/strong\u003e 2.072 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2057\" data-end=\"2073\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2074\" data-end=\"2339\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1e8jn5z\" data-start=\"2074\" data-end=\"2113\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1p888fg\" data-start=\"2114\" data-end=\"2146\"\u003eIndustrial Electrical Networks\u003c\/li\u003e\n\u003cli data-section-id=\"mioo3r\" data-start=\"2147\" data-end=\"2177\"\u003ePanelboards and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ahqzl9\" data-start=\"2178\" data-end=\"2205\"\u003eFeeder Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"zwhbd8\" data-start=\"2206\" data-end=\"2233\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1pcj2h0\" data-start=\"2234\" data-end=\"2270\"\u003eEquipment and Machinery Protection\u003c\/li\u003e\n\u003cli data-section-id=\"74bo7g\" data-start=\"2271\" data-end=\"2304\"\u003eHigh Fault Current Applications\u003c\/li\u003e\n\u003cli data-section-id=\"13yxf8f\" data-start=\"2305\" data-end=\"2339\" data-is-last-node=\"\"\u003eLow-Voltage Distribution Systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48486348914937,"sku":"3VA5130-6ED31-0AA0","price":512.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA4111-5ED34-0AA0-All-New-1_45f6032f-6e4d-4eea-a435-4c163a507c86.webp?v=1780593178","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5130-6ed31-0aa0-30-amp-3-pole-molded-case-circuit-breaker-feed-thru-mount-600v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}