{"product_id":"siemens-3va5160-4ed21-0aa0-60-amp-2-pole-molded-case-circuit-breaker-panel-mount-240-480-600y-347vac-250vdc","title":"Siemens 3VA5160-4ED21-0AA0 60 Amp 2-Pole Molded Case Circuit Breaker – Panel Mount – 240\/480\/600Y-347VAC \u0026 250VDC","description":"\u003cp data-start=\"139\" data-end=\"860\"\u003e\u003cbr data-start=\"155\" data-end=\"158\"\u003eThe Siemens 3VA5160-4ED21-0AA0 is a compact and versatile molded case circuit breaker (MCCB) designed for commercial and industrial power distribution applications. Built on the 125A SENTRON 3VA51 frame, this 2-pole, 60A breaker maximizes panel space while delivering dependable overcurrent and short-circuit protection. Equipped with a thermal-magnetic trip unit featuring fixed long-time and instantaneous (LI) protection settings, it provides reliable circuit protection for a wide range of electrical systems. The breaker is designed for installation in Siemens P1, P2, and P3 panelboards, SB switchboards, and motor control centers, and serves as a direct replacement for legacy ED62B060 breakers.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"862\" data-end=\"884\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"885\" data-end=\"1119\"\u003e\n\u003cli data-section-id=\"ksj85x\" data-start=\"885\" data-end=\"914\"\u003e\n\u003cstrong data-start=\"887\" data-end=\"906\"\u003eCurrent Rating:\u003c\/strong\u003e 60 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"2aay8j\" data-start=\"915\" data-end=\"972\"\u003e\n\u003cstrong data-start=\"917\" data-end=\"936\"\u003eVoltage Rating:\u003c\/strong\u003e 240VAC, 480VAC, 600Y\/347VAC, 250VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1cl61ag\" data-start=\"973\" data-end=\"998\"\u003e\n\u003cstrong data-start=\"975\" data-end=\"985\"\u003ePhase:\u003c\/strong\u003e Single Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1k2j0h4\" data-start=\"999\" data-end=\"1024\"\u003e\n\u003cstrong data-start=\"1001\" data-end=\"1015\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"fn980i\" data-start=\"1025\" data-end=\"1119\"\u003e\n\u003cstrong data-start=\"1027\" data-end=\"1042\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1045\" data-end=\"1119\"\u003e\n\u003cli data-section-id=\"hzrd8j\" data-start=\"1045\" data-end=\"1060\"\u003e65kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"yr8mx9\" data-start=\"1063\" data-end=\"1078\"\u003e25kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"jpg8o3\" data-start=\"1081\" data-end=\"1101\"\u003e14kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"rkzitd\" data-start=\"1104\" data-end=\"1119\"\u003e50kA @ 250VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1121\" data-end=\"1143\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1144\" data-end=\"1670\"\u003e\n\u003cli data-section-id=\"13z4f0o\" data-start=\"1144\" data-end=\"1198\"\u003e\n\u003cstrong data-start=\"1146\" data-end=\"1163\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"exr5l3\" data-start=\"1199\" data-end=\"1225\"\u003e\n\u003cstrong data-start=\"1201\" data-end=\"1212\"\u003eSeries:\u003c\/strong\u003e SENTRON 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"a2jk9i\" data-start=\"1226\" data-end=\"1263\"\u003e\n\u003cstrong data-start=\"1228\" data-end=\"1244\"\u003ePart Number:\u003c\/strong\u003e 3VA5160-4ED21-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"1hflush\" data-start=\"1264\" data-end=\"1300\"\u003e\n\u003cstrong data-start=\"1266\" data-end=\"1281\"\u003eFrame Size:\u003c\/strong\u003e 125A (3VA51 Frame)\u003c\/li\u003e\n\u003cli data-section-id=\"1ancmt0\" data-start=\"1301\" data-end=\"1330\"\u003e\n\u003cstrong data-start=\"1303\" data-end=\"1323\"\u003eNumber of Poles:\u003c\/strong\u003e 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1l1n3xv\" data-start=\"1331\" data-end=\"1364\"\u003e\n\u003cstrong data-start=\"1333\" data-end=\"1352\"\u003eMounting Style:\u003c\/strong\u003e Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"fii6mb\" data-start=\"1365\" data-end=\"1390\"\u003e\n\u003cstrong data-start=\"1367\" data-end=\"1385\"\u003eTerminal Type:\u003c\/strong\u003e Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"9uld3y\" data-start=\"1391\" data-end=\"1430\"\u003e\n\u003cstrong data-start=\"1393\" data-end=\"1413\"\u003eTrip Technology:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"10ttgyv\" data-start=\"1431\" data-end=\"1459\"\u003e\n\u003cstrong data-start=\"1433\" data-end=\"1456\"\u003eTrip Function Code:\u003c\/strong\u003e LI\u003c\/li\u003e\n\u003cli data-section-id=\"16robjh\" data-start=\"1460\" data-end=\"1519\"\u003e\n\u003cstrong data-start=\"1462\" data-end=\"1480\"\u003eTrip Function:\u003c\/strong\u003e Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"owid63\" data-start=\"1520\" data-end=\"1575\"\u003e\n\u003cstrong data-start=\"1522\" data-end=\"1545\"\u003eTrip Adjustability:\u003c\/strong\u003e Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"2144i0\" data-start=\"1576\" data-end=\"1670\"\u003e\n\u003cstrong data-start=\"1578\" data-end=\"1595\"\u003eFor Use With:\u003c\/strong\u003e Siemens P1, P2, P3 Panelboards, SB Switchboards, and Motor Control Centers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1672\" data-end=\"1700\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1701\" data-end=\"2036\"\u003e\n\u003cli data-section-id=\"15vnhe0\" data-start=\"1701\" data-end=\"1772\"\u003e\n\u003cstrong data-start=\"1703\" data-end=\"1729\"\u003eConstruction Features:\u003c\/strong\u003e HACR Rated, Current Limiting, Reverse Feed\u003c\/li\u003e\n\u003cli data-section-id=\"h60rf3\" data-start=\"1773\" data-end=\"1812\"\u003e\n\u003cstrong data-start=\"1775\" data-end=\"1798\"\u003eTemperature Rating:\u003c\/strong\u003e -25°C to 70°C\u003c\/li\u003e\n\u003cli data-section-id=\"7vj13n\" data-start=\"1813\" data-end=\"1864\"\u003e\n\u003cstrong data-start=\"1815\" data-end=\"1840\"\u003eAccessories Included:\u003c\/strong\u003e None (No Lugs Included)\u003c\/li\u003e\n\u003cli data-section-id=\"10nxbx1\" data-start=\"1865\" data-end=\"2036\"\u003e\n\u003cstrong data-start=\"1867\" data-end=\"1889\"\u003eAvailable Options:\u003c\/strong\u003e Auxiliary Switch, Alarm Switch, Shunt Trip, Undervoltage Release, Motor Operator, Handle Lock, Padlock Attachment, DIN Rail Adapter, Busbar System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2038\" data-end=\"2065\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2066\" data-end=\"2152\"\u003e\n\u003cli data-section-id=\"sz8gzm\" data-start=\"2066\" data-end=\"2108\"\u003e\n\u003cstrong data-start=\"2068\" data-end=\"2082\"\u003eStandards:\u003c\/strong\u003e IEC 60947-2, UL 489, HACR\u003c\/li\u003e\n\u003cli data-section-id=\"9u99yc\" data-start=\"2109\" data-end=\"2152\"\u003e\n\u003cstrong data-start=\"2111\" data-end=\"2125\"\u003eApprovals:\u003c\/strong\u003e ABS, CE, CSA, EAC, UL, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2154\" data-end=\"2170\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"2171\" data-end=\"2255\"\u003e\n\u003cli data-section-id=\"7xjvzj\" data-start=\"2171\" data-end=\"2198\"\u003e\n\u003cstrong data-start=\"2173\" data-end=\"2190\"\u003eManufacturer:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"l7ajc\" data-start=\"2199\" data-end=\"2217\"\u003e\n\u003cstrong data-start=\"2201\" data-end=\"2212\"\u003eSeries:\u003c\/strong\u003e 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"a2jk9i\" data-start=\"2218\" data-end=\"2255\"\u003e\n\u003cstrong data-start=\"2220\" data-end=\"2236\"\u003ePart Number:\u003c\/strong\u003e 3VA5160-4ED21-0AA0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2257\" data-end=\"2273\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2274\" data-end=\"2582\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1e8jn5z\" data-start=\"2274\" data-end=\"2313\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"xl1m6\" data-start=\"2314\" data-end=\"2351\"\u003eIndustrial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"mioo3r\" data-start=\"2352\" data-end=\"2382\"\u003ePanelboards and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"c04670\" data-start=\"2383\" data-end=\"2406\"\u003eMotor Control Centers\u003c\/li\u003e\n\u003cli data-section-id=\"1lrsr2q\" data-start=\"2407\" data-end=\"2445\"\u003eFeeder and Branch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"s1rvbh\" data-start=\"2446\" data-end=\"2493\"\u003eHVAC Equipment Protection (HACR Applications)\u003c\/li\u003e\n\u003cli data-section-id=\"1dklbos\" data-start=\"2494\" data-end=\"2531\"\u003eCurrent-Limiting Protection Systems\u003c\/li\u003e\n\u003cli data-section-id=\"12ieyq4\" data-start=\"2532\" data-end=\"2582\" data-is-last-node=\"\"\u003eReplacement of Siemens ED62B060 Circuit Breakers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48488998535417,"sku":"3VA5160-4ED21-0AA0","price":361.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5120-4ED21-0AA0_1_19cf6a4f-ccbf-4929-9e00-28b19b566fe8.webp?v=1780676602","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5160-4ed21-0aa0-60-amp-2-pole-molded-case-circuit-breaker-panel-mount-240-480-600y-347vac-250vdc","provider":"My Circuit Breakers","version":"1.0","type":"link"}