{"product_id":"siemens-3va5160-6ec31-0aa0-60-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600y-347vac-500vdc","title":"Siemens 3VA5160-6EC31-0AA0 60 Amp 3-Pole Molded Case Circuit Breaker – Panel Mount – 240\/480\/600Y-347VAC \u0026 500VDC","description":"\u003cp data-start=\"139\" data-end=\"1050\"\u003eThe Siemens 3VA5160-6EC31-0AA0 is a high-performance molded case circuit breaker (MCCB) engineered for demanding industrial and commercial power distribution applications. Part of the SENTRON 3VA5 series, this 3-pole, 60A breaker provides dependable long-time and instantaneous (LI) protection through its TM230 thermal-magnetic trip unit. Featuring fixed thermal protection and adjustable magnetic settings, it offers enhanced flexibility for coordinating protection with system requirements. Designed for installation in Siemens 3VA panelboards, Siemens P1 panelboards (with adapter), and switchboards, it serves as a direct replacement for legacy HHED63B060 and HED43B060 circuit breakers. With a high interrupting capacity of 65kA at 480VAC, HACR certification, HID suitability, and reverse-feed capability, this breaker delivers reliable fault protection for critical electrical systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"1052\" data-end=\"1074\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"1075\" data-end=\"1306\"\u003e\n\u003cli data-section-id=\"ksj85x\" data-start=\"1075\" data-end=\"1104\"\u003e\n\u003cstrong data-start=\"1077\" data-end=\"1096\"\u003eCurrent Rating:\u003c\/strong\u003e 60 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1vo15dd\" data-start=\"1105\" data-end=\"1162\"\u003e\n\u003cstrong data-start=\"1107\" data-end=\"1126\"\u003eVoltage Rating:\u003c\/strong\u003e 240VAC, 480VAC, 600Y\/347VAC, 500VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1murovg\" data-start=\"1163\" data-end=\"1183\"\u003e\n\u003cstrong data-start=\"1165\" data-end=\"1175\"\u003ePhase:\u003c\/strong\u003e 3-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1k2j0h4\" data-start=\"1184\" data-end=\"1209\"\u003e\n\u003cstrong data-start=\"1186\" data-end=\"1200\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"17h5flc\" data-start=\"1210\" data-end=\"1306\"\u003e\n\u003cstrong data-start=\"1212\" data-end=\"1227\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1230\" data-end=\"1306\"\u003e\n\u003cli data-section-id=\"12n729d\" data-start=\"1230\" data-end=\"1246\"\u003e100kA @ 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"jd9qfd\" data-start=\"1249\" data-end=\"1264\"\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli data-section-id=\"wqlh6p\" data-start=\"1267\" data-end=\"1287\"\u003e25kA @ 600Y\/347VAC\u003c\/li\u003e\n\u003cli data-section-id=\"14joncn\" data-start=\"1290\" data-end=\"1306\"\u003e100kA @ 500VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1308\" data-end=\"1330\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1331\" data-end=\"1854\"\u003e\n\u003cli data-section-id=\"13z4f0o\" data-start=\"1331\" data-end=\"1385\"\u003e\n\u003cstrong data-start=\"1333\" data-end=\"1350\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"exr5l3\" data-start=\"1386\" data-end=\"1412\"\u003e\n\u003cstrong data-start=\"1388\" data-end=\"1399\"\u003eSeries:\u003c\/strong\u003e SENTRON 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"2ukjw2\" data-start=\"1413\" data-end=\"1450\"\u003e\n\u003cstrong data-start=\"1415\" data-end=\"1431\"\u003ePart Number:\u003c\/strong\u003e 3VA5160-6EC31-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"1b7sbdh\" data-start=\"1451\" data-end=\"1480\"\u003e\n\u003cstrong data-start=\"1453\" data-end=\"1473\"\u003eNumber of Poles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1l1n3xv\" data-start=\"1481\" data-end=\"1514\"\u003e\n\u003cstrong data-start=\"1483\" data-end=\"1502\"\u003eMounting Style:\u003c\/strong\u003e Panel Mount\u003c\/li\u003e\n\u003cli data-section-id=\"fii6mb\" data-start=\"1515\" data-end=\"1540\"\u003e\n\u003cstrong data-start=\"1517\" data-end=\"1535\"\u003eTerminal Type:\u003c\/strong\u003e Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"9uld3y\" data-start=\"1541\" data-end=\"1580\"\u003e\n\u003cstrong data-start=\"1543\" data-end=\"1563\"\u003eTrip Technology:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1veldkz\" data-start=\"1581\" data-end=\"1603\"\u003e\n\u003cstrong data-start=\"1583\" data-end=\"1597\"\u003eTrip Unit:\u003c\/strong\u003e TM230\u003c\/li\u003e\n\u003cli data-section-id=\"10ttgyv\" data-start=\"1604\" data-end=\"1632\"\u003e\n\u003cstrong data-start=\"1606\" data-end=\"1629\"\u003eTrip Function Code:\u003c\/strong\u003e LI\u003c\/li\u003e\n\u003cli data-section-id=\"16robjh\" data-start=\"1633\" data-end=\"1692\"\u003e\n\u003cstrong data-start=\"1635\" data-end=\"1653\"\u003eTrip Function:\u003c\/strong\u003e Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"139l8iy\" data-start=\"1693\" data-end=\"1753\"\u003e\n\u003cstrong data-start=\"1695\" data-end=\"1718\"\u003eTrip Adjustability:\u003c\/strong\u003e Fixed Thermal, Adjustable Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"fjrqbt\" data-start=\"1754\" data-end=\"1854\"\u003e\n\u003cstrong data-start=\"1756\" data-end=\"1773\"\u003eFor Use With:\u003c\/strong\u003e Siemens 3VA Panelboards, Siemens P1 Panelboards (with adapter), and Switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1856\" data-end=\"1884\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1885\" data-end=\"2160\"\u003e\n\u003cli data-section-id=\"hltzw7\" data-start=\"1885\" data-end=\"1949\"\u003e\n\u003cstrong data-start=\"1887\" data-end=\"1913\"\u003eConstruction Features:\u003c\/strong\u003e HACR Rated, HID Rated, Reverse Feed\u003c\/li\u003e\n\u003cli data-section-id=\"h60rf3\" data-start=\"1950\" data-end=\"1989\"\u003e\n\u003cstrong data-start=\"1952\" data-end=\"1975\"\u003eTemperature Rating:\u003c\/strong\u003e -25°C to 70°C\u003c\/li\u003e\n\u003cli data-section-id=\"1ege0pv\" data-start=\"1990\" data-end=\"2034\"\u003e\n\u003cstrong data-start=\"1992\" data-end=\"2017\"\u003eAccessories Included:\u003c\/strong\u003e Nut Keeper Plate\u003c\/li\u003e\n\u003cli data-section-id=\"1atc3nu\" data-start=\"2035\" data-end=\"2160\"\u003e\n\u003cstrong data-start=\"2037\" data-end=\"2059\"\u003eAvailable Options:\u003c\/strong\u003e Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"2162\" data-end=\"2189\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2190\" data-end=\"2260\"\u003e\n\u003cli data-section-id=\"ujtupi\" data-start=\"2190\" data-end=\"2226\"\u003e\n\u003cstrong data-start=\"2192\" data-end=\"2206\"\u003eStandards:\u003c\/strong\u003e IEC 60947-2, UL 489\u003c\/li\u003e\n\u003cli data-section-id=\"lba8lv\" data-start=\"2227\" data-end=\"2260\"\u003e\n\u003cstrong data-start=\"2229\" data-end=\"2243\"\u003eApprovals:\u003c\/strong\u003e CE, CSA, UL, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"2262\" data-end=\"2278\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"2279\" data-end=\"2363\"\u003e\n\u003cli data-section-id=\"7xjvzj\" data-start=\"2279\" data-end=\"2306\"\u003e\n\u003cstrong data-start=\"2281\" data-end=\"2298\"\u003eManufacturer:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"l7ajc\" data-start=\"2307\" data-end=\"2325\"\u003e\n\u003cstrong data-start=\"2309\" data-end=\"2320\"\u003eSeries:\u003c\/strong\u003e 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"2ukjw2\" data-start=\"2326\" data-end=\"2363\"\u003e\n\u003cstrong data-start=\"2328\" data-end=\"2344\"\u003ePart Number:\u003c\/strong\u003e 3VA5160-6EC31-0AA0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2365\" data-end=\"2381\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2382\" data-end=\"2718\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"vc8hdo\" data-start=\"2382\" data-end=\"2421\"\u003eIndustrial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1aq811x\" data-start=\"2422\" data-end=\"2459\"\u003eCommercial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"7zoclv\" data-start=\"2460\" data-end=\"2492\"\u003eSiemens 3VA and P1 Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1lgh42b\" data-start=\"2493\" data-end=\"2507\"\u003eSwitchboards\u003c\/li\u003e\n\u003cli data-section-id=\"1lrsr2q\" data-start=\"2508\" data-end=\"2546\"\u003eFeeder and Branch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"s1rvbh\" data-start=\"2547\" data-end=\"2594\"\u003eHVAC Equipment Protection (HACR Applications)\u003c\/li\u003e\n\u003cli data-section-id=\"pubehx\" data-start=\"2595\" data-end=\"2617\"\u003eHID Lighting Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1alk6tf\" data-start=\"2618\" data-end=\"2651\"\u003eHigh Fault Current Environments\u003c\/li\u003e\n\u003cli data-section-id=\"1kze3r0\" data-start=\"2652\" data-end=\"2718\" data-is-last-node=\"\"\u003eReplacement of Siemens HHED63B060 and HED43B060 Circuit Breakers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48489042575609,"sku":"3VA5160-6EC31-0AA0","price":567.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/3VA5110-4EC31-0AA0-3-Pole-Circuit-Breaker_Siemens-1_da660d76-c0ec-4d32-9b12-098baeba984d.webp?v=1780677490","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5160-6ec31-0aa0-60-amp-3-pole-molded-case-circuit-breaker-panel-mount-240-480-600y-347vac-500vdc","provider":"My Circuit Breakers","version":"1.0","type":"link"}