{"product_id":"siemens-3va5195-4ed21-0aa0-15-amp-2-pole-molded-case-circuit-breaker-feed-thru-mount-480v-ac","title":"Siemens 3VA5195-4ED21-0AA0 15 Amp 2-Pole Molded Case Circuit Breaker – Feed-Thru Mount – 480V AC","description":"\u003cp data-start=\"122\" data-end=\"887\"\u003eThe Siemens 3VA5195-4ED21-0AA0 is a compact molded case circuit breaker (MCCB) designed for dependable circuit protection in commercial and industrial electrical distribution systems. Part of the Siemens 3VA5 family, this 2-pole, 15A breaker is built on a 125A frame and utilizes a TM210 thermal-magnetic trip unit for reliable overload and short-circuit protection. Featuring Standard (Class S) breaking capacity, it provides an interrupting rating of 25kA at 480VAC. The breaker incorporates permanently set overload protection and fixed instantaneous trip settings, ensuring consistent protection performance. Supplied without connection lugs, it is ideal for low-voltage power distribution applications requiring compact, reliable protection.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yc43s8\" data-start=\"889\" data-end=\"911\"\u003eVoltage and Rating\u003c\/h3\u003e\n\u003cul data-start=\"912\" data-end=\"1074\"\u003e\n\u003cli data-section-id=\"15jl987\" data-start=\"912\" data-end=\"941\"\u003e\n\u003cstrong data-start=\"914\" data-end=\"933\"\u003eCurrent Rating:\u003c\/strong\u003e 15 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"105muxn\" data-start=\"942\" data-end=\"976\"\u003e\n\u003cstrong data-start=\"944\" data-end=\"963\"\u003eVoltage Rating:\u003c\/strong\u003e 480 Volts AC\u003c\/li\u003e\n\u003cli data-section-id=\"1cl61ag\" data-start=\"977\" data-end=\"1002\"\u003e\n\u003cstrong data-start=\"979\" data-end=\"989\"\u003ePhase:\u003c\/strong\u003e Single Phase\u003c\/li\u003e\n\u003cli data-section-id=\"1k2j0h4\" data-start=\"1003\" data-end=\"1028\"\u003e\n\u003cstrong data-start=\"1005\" data-end=\"1019\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"ct6izk\" data-start=\"1029\" data-end=\"1074\"\u003e\n\u003cstrong data-start=\"1031\" data-end=\"1046\"\u003eAIC Rating:\u003c\/strong\u003e\n\u003cul data-start=\"1049\" data-end=\"1074\"\u003e\n\u003cli data-section-id=\"m50i6p\" data-start=\"1049\" data-end=\"1074\"\u003e25kA @ 480VAC (Class S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"uvdx3z\" data-start=\"1076\" data-end=\"1098\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1099\" data-end=\"1611\"\u003e\n\u003cli data-section-id=\"13z4f0o\" data-start=\"1099\" data-end=\"1153\"\u003e\n\u003cstrong data-start=\"1101\" data-end=\"1118\"\u003eBreaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"l7ajc\" data-start=\"1154\" data-end=\"1172\"\u003e\n\u003cstrong data-start=\"1156\" data-end=\"1167\"\u003eSeries:\u003c\/strong\u003e 3VA5\u003c\/li\u003e\n\u003cli data-section-id=\"7o3gqo\" data-start=\"1173\" data-end=\"1190\"\u003e\n\u003cstrong data-start=\"1175\" data-end=\"1186\"\u003eFamily:\u003c\/strong\u003e 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"cgvkj2\" data-start=\"1191\" data-end=\"1206\"\u003e\n\u003cstrong data-start=\"1193\" data-end=\"1202\"\u003eType:\u003c\/strong\u003e 3VA\u003c\/li\u003e\n\u003cli data-section-id=\"14lfin4\" data-start=\"1207\" data-end=\"1235\"\u003e\n\u003cstrong data-start=\"1209\" data-end=\"1224\"\u003eFrame Size:\u003c\/strong\u003e 125A Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1ancmt0\" data-start=\"1236\" data-end=\"1265\"\u003e\n\u003cstrong data-start=\"1238\" data-end=\"1258\"\u003eNumber of Poles:\u003c\/strong\u003e 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1ecruw8\" data-start=\"1266\" data-end=\"1298\"\u003e\n\u003cstrong data-start=\"1268\" data-end=\"1288\"\u003eConnection Type:\u003c\/strong\u003e Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"ohafh0\" data-start=\"1299\" data-end=\"1327\"\u003e\n\u003cstrong data-start=\"1301\" data-end=\"1315\"\u003eTrip Unit:\u003c\/strong\u003e TM210, FTFM\u003c\/li\u003e\n\u003cli data-section-id=\"1hbpbh8\" data-start=\"1328\" data-end=\"1367\"\u003e\n\u003cstrong data-start=\"1330\" data-end=\"1350\"\u003eProtection Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1onu9fb\" data-start=\"1368\" data-end=\"1428\"\u003e\n\u003cstrong data-start=\"1370\" data-end=\"1384\"\u003eFunctions:\u003c\/strong\u003e LI – Long-Time and Instantaneous Protection\u003c\/li\u003e\n\u003cli data-section-id=\"19yh29c\" data-start=\"1429\" data-end=\"1455\"\u003e\n\u003cstrong data-start=\"1431\" data-end=\"1451\"\u003eLine Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-section-id=\"3lmq4r\" data-start=\"1456\" data-end=\"1507\"\u003e\n\u003cstrong data-start=\"1458\" data-end=\"1487\"\u003eOverload Protection (Ir):\u003c\/strong\u003e 15A Permanently Set\u003c\/li\u003e\n\u003cli data-section-id=\"ur4a7t\" data-start=\"1508\" data-end=\"1560\"\u003e\n\u003cstrong data-start=\"1510\" data-end=\"1544\"\u003eShort-Circuit Protection (Ii):\u003c\/strong\u003e 20 × In (Fixed)\u003c\/li\u003e\n\u003cli data-section-id=\"tvoxqm\" data-start=\"1561\" data-end=\"1611\"\u003e\n\u003cstrong data-start=\"1563\" data-end=\"1592\"\u003eConnection Configuration:\u003c\/strong\u003e Without Connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1613\" data-end=\"1641\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1642\" data-end=\"1867\"\u003e\n\u003cli data-section-id=\"1aylqxc\" data-start=\"1642\" data-end=\"1691\"\u003e\n\u003cstrong data-start=\"1644\" data-end=\"1672\"\u003eBreaking Capacity Class:\u003c\/strong\u003e Standard (Class S)\u003c\/li\u003e\n\u003cli data-section-id=\"dwpz3u\" data-start=\"1692\" data-end=\"1756\"\u003e\n\u003cstrong data-start=\"1694\" data-end=\"1718\"\u003eProtection Features:\u003c\/strong\u003e Overload and Short-Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"yf2079\" data-start=\"1757\" data-end=\"1803\"\u003e\n\u003cstrong data-start=\"1759\" data-end=\"1776\"\u003eConstruction:\u003c\/strong\u003e Compact Molded Case Design\u003c\/li\u003e\n\u003cli data-section-id=\"1k7miyl\" data-start=\"1804\" data-end=\"1867\"\u003e\n\u003cstrong data-start=\"1806\" data-end=\"1822\"\u003eApplication:\u003c\/strong\u003e Commercial and Industrial Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nr5bwx\" data-start=\"1869\" data-end=\"1896\"\u003eStandards and Approvals\u003c\/h3\u003e\n\u003cul data-start=\"1897\" data-end=\"1930\"\u003e\n\u003cli data-section-id=\"19vv1m8\" data-start=\"1897\" data-end=\"1930\"\u003e\n\u003cstrong data-start=\"1899\" data-end=\"1917\"\u003eCertification:\u003c\/strong\u003e CSA Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1aljov1\" data-start=\"1932\" data-end=\"1948\"\u003eProduct Data\u003c\/h3\u003e\n\u003cul data-start=\"1949\" data-end=\"2032\"\u003e\n\u003cli data-section-id=\"7xjvzj\" data-start=\"1949\" data-end=\"1976\"\u003e\n\u003cstrong data-start=\"1951\" data-end=\"1968\"\u003eManufacturer:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli data-section-id=\"deoc8s\" data-start=\"1977\" data-end=\"2014\"\u003e\n\u003cstrong data-start=\"1979\" data-end=\"1995\"\u003ePart Number:\u003c\/strong\u003e 3VA5195-4ED21-0AA0\u003c\/li\u003e\n\u003cli data-section-id=\"7o3gqo\" data-start=\"2015\" data-end=\"2032\"\u003e\n\u003cstrong data-start=\"2017\" data-end=\"2028\"\u003eFamily:\u003c\/strong\u003e 3VA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ddop7y\" data-start=\"2034\" data-end=\"2059\"\u003eDimensions and Weight\u003c\/h3\u003e\n\u003cul data-start=\"2060\" data-end=\"2082\"\u003e\n\u003cli data-section-id=\"1uaufue\" data-start=\"2060\" data-end=\"2082\"\u003e\n\u003cstrong data-start=\"2062\" data-end=\"2073\"\u003eWeight:\u003c\/strong\u003e 1.42 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2084\" data-end=\"2100\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2101\" data-end=\"2378\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1e8jn5z\" data-start=\"2101\" data-end=\"2140\"\u003eCommercial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"xl1m6\" data-start=\"2141\" data-end=\"2178\"\u003eIndustrial Electrical Installations\u003c\/li\u003e\n\u003cli data-section-id=\"mioo3r\" data-start=\"2179\" data-end=\"2209\"\u003ePanelboards and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"ahqzl9\" data-start=\"2210\" data-end=\"2237\"\u003eFeeder Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"zwhbd8\" data-start=\"2238\" data-end=\"2265\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1j11aht\" data-start=\"2266\" data-end=\"2288\"\u003eEquipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"jeo8ne\" data-start=\"2289\" data-end=\"2305\"\u003eControl Panels\u003c\/li\u003e\n\u003cli data-section-id=\"uk75xg\" data-start=\"2306\" data-end=\"2341\"\u003eLow-Voltage Distribution Networks\u003c\/li\u003e\n\u003cli data-section-id=\"1wraoz4\" data-start=\"2342\" data-end=\"2378\" data-is-last-node=\"\"\u003eGeneral Purpose Circuit Protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens \/ ITE","offers":[{"title":"NEW","offer_id":48490722328825,"sku":": 3VA5195-4ED21-0AA0","price":361.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/G_I202_XX_53599i_e2c29ffd-bc7b-4633-951d-6a8047f4e380.jpg?v=1780739283","url":"https:\/\/mycircuitbreakers.com\/products\/siemens-3va5195-4ed21-0aa0-15-amp-2-pole-molded-case-circuit-breaker-feed-thru-mount-480v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}